Description
| Ordering | |
| Minimum Order Quantity: | 1 piece |
| Customs Tariff Number: | 85364900 |
| Popular Downloads | |
| Data Sheet, Technical Information: | 1SBC100214C0202 – Main catalog Motor protection and control Manual motor starters, contactors and overload relays (PDF) – Edition 2024 |
| Instructions and Manuals: | 1SFC380023-en |
| CAD Dimensional Drawing: | Information – 2D and 3D files for CAD systems |
| Dimension Diagram: | 53540919-59 |
| Dimensions | |
| Product Net Width: | 186 mm |
| Product Net Depth / Length: | 216 mm |
| Product Net Height: | 278 mm |
| Product Net Weight: | 10.6 kg |
| Technical | |
| Number of Main Contacts NO: | 3 |
| Number of Main Contacts NC: | 0 |
| Number of Auxiliary Contacts NO: | 1 |
| Number of Auxiliary Contacts NC: | 1 |
| Number of Poles: | 3P |
| Rated Operational Voltage: | Main Circuit 1000 V |
| Rated Frequency (f): | Main Circuit 50 / 60 Hz |
| Conventional Free-air Thermal Current (Ith): | acc. to IEC 60947-4-1, Open Contactors Θ = 40 °C 600 A |
| Rated Operational Current AC-1 (Ie): | (1000 V) 40 °C 600 A (1000 V) 55 °C 500 A (1000 V) 70 °C 400 A (690 V) 40 °C 600 A (690 V) 55 °C 500 A (690 V) 70 °C 400 A |
| Rated Operational Current AC-3 (Ie): | (415 V) 55 °C 400 A (440 V) 55 °C 400 A (500 V) 55 °C 400 A (690 V) 55 °C 350 A (1000 V) 55 °C 155 A (380 / 400 V) 55 °C 400 A (220 / 230 / 240 V) 55 °C 400 A |
| Rated Operational Current DC-1 (Ie): | (110 V) 1-Pole, 40 °C 600 A (110 V) 2 Poles in Series, 40 °C 600 A (220 V) 3 Poles in Series, 40 °C 600 A (600 V) 3 Poles in Series, 40 °C 600 A |
| Rated Operational Current DC-3 (Ie): | (110 V) 1-Pole, 40 °C 600 A (110 V) 2 Poles in Series, 40 °C 600 A (220 V) 3 Poles in Series, 40 °C 600 A (600 V) 3 Poles in Series, 40 °C 600 A |
| Rated Operational Current DC-5 (Ie): | (110 V) 1-Pole, 40 °C 600 A (110 V) 2 Poles in Series, 40 °C 600 A (220 V) 3 Poles in Series, 40 °C 600 A (600 V) 3 Poles in Series, 40 °C 600 A |
| Rated Operational Power AC-3 (Pe): | (415 V) 220 kW (440 V) 220 kW (500 V) 250 kW (690 V) 315 kW (1000 V) 220 kW (380 / 400 V) 200 kW (220 / 230 / 240 V) 110 kW |
| Rated Breaking Capacity AC-3: | 8 x Ie AC-3 |
| Rated Making Capacity AC-3: | 10 x Ie AC-3 |
| Short-Circuit Protective Devices: | gG Type Fuses 630 A |
| Rated Short-time Withstand Current Low Voltage (Icw): | at 40 °C Ambient Temp, in Free Air, from a Cold State 10 s 4400 A at 40 °C Ambient Temp, in Free Air, from a Cold State 15 min 840 A at 40 °C Ambient Temp, in Free Air, from a Cold State 1 min 2500 A at 40 °C Ambient Temp, in Free Air, from a Cold State 1 s 4600 A at 40 °C Ambient Temp, in Free Air, from a Cold State 30 s 3100 A |
| Maximum Breaking Capacity: | cos phi=0.45 (cos phi=0.35 for Ie > 100 A) at 440 V 4000 A cos phi=0.45 (cos phi=0.35 for Ie > 100 A) at 690 V 3500 A |
| Rated Insulation Voltage (Ui): | acc. to IEC 60947-4-1 and VDE 0110 (Gr. C) 1000 V acc. to UL/CSA 600 V |
| Rated Impulse Withstand Voltage (Uimp): | Main Circuit 8 kV |
| Maximum Electrical Switching Frequency: | (AC-1) 300 cycles per hour (AC-2 / AC-4) 60 cycles per hour (AC-3) 300 cycles per hour |
| Mechanical Durability: | 3 million |
| Maximum Mechanical Switching Frequency: | 300 cycles per hour |
| Coil Operating Limits: | (acc. to IEC 60947-4-1) 0.85 x Uc Min. … 1.1 x Uc Max. (at θ ≤ 70 °C) |
| Rated Control Circuit Voltage (Uc): | 50 Hz 48 … 130 V 60 Hz 48 … 130 V DC Operation 48 … 130 V |
| Coil Consumption: | Holding at Max. Rated Control Circuit Voltage 50 Hz 12 V·A Holding at Max. Rated Control Circuit Voltage 60 Hz 12 V·A Holding at Max. Rated Control Circuit Voltage DC 5 V·A Pull-in at Max. Rated Control Circuit Voltage 50 Hz 1215 V·A Pull-in at Max. Rated Control Circuit Voltage 60 Hz 1215 V·A Pull-in at Max. Rated Control Circuit Voltage DC 1150 V·A |
| Power Loss: | at Rated Operating Conditions per Pole 16 W |
| Operate Time: | Between Coil De-energization and NC Contact Closing 45 … 55 ms Between Coil De-energization and NO Contact Opening 48 … 58 ms Between Coil Energization and NC Contact Opening 45 … 115 ms Between Coil Energization and NO Contact Closing 50 … 120 ms |
| Connecting Capacity Main Circuit: | Bar 47 mm² Rigid Al-Cable 240 mm² Rigid Cu-Cable 240 mm² |
| Connecting Capacity Auxiliary Circuit: | Flexible with Ferrule 2x 0.75 … 2.5 mm² Flexible with Insulated Ferrule 2x 0.75 … 2.5 mm² Flexible 2×0.75 … 2.5 mm² Solid 2 x 1 … 4 mm² Stranded 2 x 1 …. 4 mm² |
| Connecting Capacity: | Bar 47 mm² Rigid Al-Cable 2×240 mm² Rigid Cu-Cable 240 mm² |
| Degree of Protection: | acc. to IEC 60529, IEC 60947-1, EN 60529 Coil Terminals IP20 acc. to IEC 60529, IEC 60947-1, EN 60529 Main Terminals IP00 |
| Tightening Torque: | Cable Lug 35 N·m Main Circuit 35 N·m |
| Terminal Type: | Main Circuit: Bars |
| Product Name: | Block Contactor |
| Technical UL/CSA | |
| Maximum Operating Voltage UL/CSA: | Main Circuit 1000 V |
| General Use Rating UL/CSA: | (600 V AC) 550 A |
| Horsepower Rating UL/CSA: | (200 V AC) Three Phase 125 hp (208 V AC) Three Phase 125 hp (220 … 240 V AC) Three Phase 150 hp (440 … 480 V AC) Three Phase 350 hp (550 … 600 V AC) Three Phase 400 hp |
| Full Load Amps Motor Use: | (440 … 480 V AC) Three Phase 414 A (550 … 600 V AC) Three Phase 382 A |
| Environmental | |
| Ambient Air Temperature: | Close to Contactor Fitted with Thermal O/L Relay (0.85 … 1.1 Uc) -25 … 50 °C Close to Contactor without Thermal O/L Relay (0.85 … 1.1 Uc) -40 … 70 °C Close to Contactor for Storage -40 … 70 °C |
| Maximum Operating Altitude Permissible: | Without Derating 3000 m |
| Resistance to Shock acc. to IEC 60068-2-27: | Shock Direction: A 5 g Shock Direction: B1 5 g Shock Direction: B2 5 g Shock Direction: C1 5 g Shock Direction: C2 5 g |
| Material Compliance | |
| Conflict Minerals Reporting Template (CMRT): | CMRT – Conflict Minerals Reporting Template |
| REACH Declaration: | REACH – Letter of Confirmation for block contactors, contactor relays, installation contactors, mini contactors, mini contactor relays, thermal overload relays, electronic overload relays and related accessories |
| RoHS Information: | RoHS II declaration for block contactors, installation contactors, mini contactors, mini contactor relays, thermal overload relays, electronic overload relays and related accessories |
| RoHS Status: | Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019 |
| Toxic Substances Control Act – TSCA: | Toxic Substances Control Act (TSCA) declaration for Contactors |
| WEEE B2C / B2B: | Business To Business |
| WEEE Category: | 5. Small Equipment (No External Dimension More Than 50 cm) |
| ABB EcoSolutions | |
| ABB EcoSolutions: | Yes |
| ABB Site Meeting Group Waste To Landfill Target: | Non-hazardous waste is sent to a landfill, where there is no alternative option available within 100km of a facility |
| End Of Life Disassembling Instructions: | End-of-life instruction – AF(S)400(B)-::;AF(S)460(B)-::;AF460N6 |
| Environmental Product Declaration – EPD: | Environmental Product Declaration, Contactors, AF(S)400-AF(S)460 (SE) |
| Improved Energy Efficiency for Customers: | Product Efficiency – Product considered more energy-efficient compared to similar product on market or older products from the same line |
| Recyclability Rate of the Product acc. to EN45555: | Design for Closing Resource Loops – Standard EN45555 – 63.1 % |
| Sustainable Material Content in Product (wt. %): | Recycled Metal – 37 % |
| Certificates and Declarations | |
| ABS Certificate: | ABS Certificate, Contactor, AF400…AF2050 (Sweden) |
| BV Certificate: | BV Certificate, Contactor, AF400 … AF2850 |
| CB Certificate: | SE-82316 |
| CCS Certificate: | CCS Certificate, Contactor, AF116 to AF2850 (Sweden) |
| CQC Certificate: | CQC Certificate, AC Contactor, AF400-30-:-:,AF460-30-:-:,AFS400-30-:-:, AFS460-30-:-:, Made in Sweden CQC Certificate, Contactor, AF400, AF460, Made in China |
| Declaration of Conformity – CCC: | CCC Declaration of Conformity, AC Contactor, AF400-30-:-:,AF460-30-:-:,AFS400-30-:-:, AFS460-30-:-:, Made in Sweden CCC Declaration of Conformity, Contactor, AF400, AF460, Made in China |
| Declaration of Conformity – CE: | CE Declaration of Conformity – Contactor – AF400…AF2850 |
| Declaration of Conformity – UKCA: | UK Declaration of Conformity – Contactors >100A |
| DNV Certificate: | DNV_E-10966 |
| DNV GL Certificate: | DNV Certificate, Contactor, AF400…AF2850 |
| EAC Certificate: | 9AKK107046A8618 |
| GL Certificate: | GL_42988-02HH |
| LOVAG Certificate: | SE-0115101 |
| LR Certificate: | Lloyds register Certificate, Contactor, AF400…AF2850 |
| PRS Certificate: | PRS Certificate – AF116…AF1650 |
| RINA Certificate: | RINA Certificate, AF95, AF110, AF145, AF185, AF210, AF260, AF300, AF400, AF460, AF580, AF750, AF1250, AF1350, AF1650, AF2050, AF2650, AF116, AF140, AF146, AF190, AF205, AF265, AF305, AF370 |
| RMRS Certificate: | 9AKK107045A6978 |
| UL Certificate: | cULus Certificate, Contactor, AF400, AF460, AFS400, AFS460 |
| UL Listing Card: | UL_E36588 |
| Container Information | |
| Package Level 1 Units: | box 1 piece |
| Package Level 1 Width: | 280 mm |
| Package Level 1 Depth / Length: | 375 mm |
| Package Level 1 Height: | 310 mm |
| Package Level 1 Gross Weight: | 12 kg |
| Package Level 1 EAN: | 7320500217832 |
| External Classifications and Standards | |
| Object Classification Code: | Q |
| ETIM 7: | EC000066 – Power contactor, AC switching |
| ETIM 8: | EC000066 – Power contactor, AC switching |
| ETIM 9: | EC000066 – Power contactor, AC switching |
| eClass: | V11.0 : 27371003 |
| UNSPSC: | 39121529 |
| IDEA Granular Category Code (IGCC): | 4758 >> Iec Contactors |
| E-Number (Norway): | 4115287 |
| E-Number (Sweden): | 3228334 |