Description
| Ordering | |
| Minimum Order Quantity: | 1 piece |
| Customs Tariff Number: | 85364900 |
| Popular Downloads | |
| Data Sheet, Technical Information: | 1SBC100214C0202 – Main catalog Motor protection and control Manual motor starters, contactors and overload relays (PDF) – Edition 2024 |
| Instructions and Manuals: | 1SFC380023-en |
| CAD Dimensional Drawing: | Information – 2D and 3D files for CAD systems |
| Dimension Diagram: | 53540919-60 |
| Dimensions | |
| Product Net Width: | 210 mm |
| Product Net Depth / Length: | 242 mm |
| Product Net Height: | 283 mm |
| Product Net Weight: | 13.6 kg |
| Technical | |
| Number of Main Contacts NO: | 3 |
| Number of Main Contacts NC: | 0 |
| Number of Auxiliary Contacts NO: | 1 |
| Number of Auxiliary Contacts NC: | 1 |
| Number of Poles: | 3P |
| Rated Operational Voltage: | Main Circuit 1000 V |
| Rated Frequency (f): | Main Circuit 50 / 60 Hz |
| Conventional Free-air Thermal Current (Ith): | acc. to IEC 60947-4-1, Open Contactors Θ = 40 °C 1050 A |
| Rated Operational Current AC-1 (Ie): | (1000 V) 40 °C 1000 A (1000 V) 55 °C 875 A (1000 V) 70 °C 720 A (690 V) 40 °C 1050 A (690 V) 55 °C 875 A (690 V) 70 °C 720 A |
| Rated Operational Current AC-3 (Ie): | (415 V) 55 °C 750 A (440 V) 55 °C 750 A (500 V) 55 °C 750 A (690 V) 55 °C 650 A (1000 V) 55 °C 300 A (380 / 400 V) 55 °C 750 A (220 / 230 / 240 V) 55 °C 750 A |
| Rated Operational Current DC-1 (Ie): | (110 V) 1-Pole, 40 °C 1050 A (110 V) 2 Poles in Series, 40 °C 1050 A (220 V) 3 Poles in Series, 40 °C 1050 A (600 V) 3 Poles in Series, 40 °C 1050 A (850 V) 3 Poles in Series, 40 °C 1050 A |
| Rated Operational Current DC-3 (Ie): | (110 V) 1-Pole, 40 °C 1050 A (110 V) 2 Poles in Series, 40 °C 1050 A (220 V) 3 Poles in Series, 40 °C 1050 A (600 V) 3 Poles in Series, 40 °C 1050 A |
| Rated Operational Current DC-5 (Ie): | (110 V) 1-Pole, 40 °C 1050 A (110 V) 2 Poles in Series, 40 °C 1050 A (220 V) 3 Poles in Series, 40 °C 1050 A (600 V) 3 Poles in Series, 40 °C 1050 A |
| Rated Operational Power AC-3 (Pe): | (415 V) 425 kW (440 V) 450 kW (500 V) 520 kW (690 V) 600 kW (1000 V) 400 kW (380 / 400 V) 400 kW (220 / 230 / 240 V) 220 kW |
| Rated Breaking Capacity AC-3: | 8 x Ie AC-3 |
| Rated Making Capacity AC-3: | 10 x Ie AC-3 |
| Short-Circuit Protective Devices: | gG Type Fuses 1000 A |
| Rated Short-time Withstand Current Low Voltage (Icw): | at 40 °C Ambient Temp, in Free Air, from a Cold State 10 s 6400 A at 40 °C Ambient Temp, in Free Air, from a Cold State 15 min 1300 A at 40 °C Ambient Temp, in Free Air, from a Cold State 1 min 3500 A at 40 °C Ambient Temp, in Free Air, from a Cold State 1 s 7000 A at 40 °C Ambient Temp, in Free Air, from a Cold State 30 s 4500 A |
| Maximum Breaking Capacity: | cos phi=0.45 (cos phi=0.35 for Ie > 100 A) at 440 V 7500 A cos phi=0.45 (cos phi=0.35 for Ie > 100 A) at 690 V 7000 A |
| Rated Insulation Voltage (Ui): | acc. to IEC 60947-4-1 and VDE 0110 (Gr. C) 1000 V acc. to UL/CSA 600 V |
| Rated Impulse Withstand Voltage (Uimp): | Main Circuit 8 kV |
| Maximum Electrical Switching Frequency: | (AC-1) 300 cycles per hour (AC-2 / AC-4) 60 cycles per hour (AC-3) 300 cycles per hour |
| Mechanical Durability: | 3 million |
| Maximum Mechanical Switching Frequency: | 300 cycles per hour |
| Coil Operating Limits: | (acc. to IEC 60947-4-1) 0.85 x Uc Min. … 1.1 x Uc Max. (at θ ≤ 70 °C) |
| Rated Control Circuit Voltage (Uc): | DC Operation 24 … 60 V |
| Coil Consumption: | Holding at Max. Rated Control Circuit Voltage 50 Hz 12 V·A Holding at Max. Rated Control Circuit Voltage 60 Hz 12 V·A Holding at Max. Rated Control Circuit Voltage DC 5.5 V·A Pull-in at Max. Rated Control Circuit Voltage 50 Hz 780 V·A Pull-in at Max. Rated Control Circuit Voltage 60 Hz 780 V·A Pull-in at Max. Rated Control Circuit Voltage DC 785 V·A |
| Power Loss: | at Rated Operating Conditions per Pole 50 W |
| Operate Time: | Between Coil De-energization and NC Contact Closing 50 … 70 ms Between Coil De-energization and NO Contact Opening 53 … 73 ms Between Coil Energization and NC Contact Opening 45 … 115 ms Between Coil Energization and NO Contact Closing 50 … 120 ms |
| Connecting Capacity Main Circuit: | Bar 52 mm² Rigid Al-Cable 300 mm² Rigid Cu-Cable 300 mm² |
| Connecting Capacity Auxiliary Circuit: | Flexible with Ferrule 2x 0.75 … 2.5 mm² Flexible with Insulated Ferrule 2x 0.75 … 2.5 mm² Flexible 2×0.75 … 2.5 mm² Solid 1 x 1 … 4 mm² Stranded 2 x 1 …. 4 mm² |
| Connecting Capacity: | Bar 52 mm² Rigid Al-Cable 300 mm² Rigid Cu-Cable 300 mm² |
| Degree of Protection: | acc. to IEC 60529, IEC 60947-1, EN 60529 Coil Terminals IP20 acc. to IEC 60529, IEC 60947-1, EN 60529 Main Terminals IP00 |
| Tightening Torque: | Cable Lug 45 N·m Main Circuit 45 N·m |
| Terminal Type: | Main Circuit: Bars |
| Product Name: | Block Contactor |
| Technical UL/CSA | |
| NEMA Size: | 7 |
| Horsepower Rating NEMA: | (230 V AC) Three Phase 300 Hp (460 V AC) Three Phase 600 Hp (575 V AC) Three Phase 600 Hp |
| Maximum Operating Voltage UL/CSA: | Main Circuit 1000 V |
| General Use Rating UL/CSA: | (1000 V AC) 900 A (600 V AC) 900 A |
| Horsepower Rating UL/CSA: | (200 V AC) Three Phase 250 hp (208 V AC) Three Phase 250 hp (220 … 240 V AC) Three Phase 300 hp (440 … 480 V AC) Three Phase 600 hp (550 … 600 V AC) Three Phase 700 hp |
| Full Load Amps Motor Use: | (440 … 480 V AC) Three Phase 722 A (550 … 600 V AC) Three Phase 672 A |
| Environmental | |
| Ambient Air Temperature: | Close to Contactor Fitted with Thermal O/L Relay (0.85 … 1.1 Uc) -25 … 50 °C Close to Contactor without Thermal O/L Relay (0.85 … 1.1 Uc) -40 … 70 °C Close to Contactor for Storage -40 … 70 °C |
| Maximum Operating Altitude Permissible: | Without Derating 3000 m |
| Resistance to Shock acc. to IEC 60068-2-27: | Shock Direction: A 5 g Shock Direction: B1 5 g Shock Direction: B2 5 g Shock Direction: C1 5 g Shock Direction: C2 5 g |
| Material Compliance | |
| Conflict Minerals Reporting Template (CMRT): | CMRT – Conflict Minerals Reporting Template |
| REACH Declaration: | REACH – Letter of Confirmation for block contactors, contactor relays, installation contactors, mini contactors, mini contactor relays, thermal overload relays, electronic overload relays and related accessories |
| RoHS Information: | RoHS II declaration for block contactors, installation contactors, mini contactors, mini contactor relays, thermal overload relays, electronic overload relays and related accessories |
| RoHS Status: | Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019 |
| Toxic Substances Control Act – TSCA: | Toxic Substances Control Act (TSCA) declaration for Contactors |
| WEEE B2C / B2B: | Business To Business |
| WEEE Category: | 5. Small Equipment (No External Dimension More Than 50 cm) |
| ABB EcoSolutions | |
| End Of Life Disassembling Instructions: | End-of-life instruction – AF(S)580(B)-::;AF(S)750(B)-::; AF750N7; AF1250(B)-:: |
| Environmental Product Declaration – EPD: | Environmental Product Declaration AF(S)580(F)(N), AF(S)750(F)(N), AF1250 (SE) Contactors |
| Certificates and Declarations | |
| ABS Certificate: | ABS Certificate, Contactor, AF400…AF2050 (Sweden) |
| BV Certificate: | BV Certificate, Contactor, AF400 … AF2850 |
| CB Certificate: | SE-82863 |
| CCS Certificate: | CCS Certificate, Contactor, AF116 to AF2850 (Sweden) |
| CQC Certificate: | CQC Certificate, AC Contactor, AF580-30-:-:, AF750-30-:-: , AFS580-30-:-:, AFS750-30-:-:, Made in Sweden CQC Certificate, Contactor, AF580, AF750, Made in China |
| CSA Certificate: | 306712-1 |
| Declaration of Conformity – CCC: | CCC Declaration of Conformity, AC Contactor, AF580-30-:-:, AF750-30-:-: , AFS580-30-:-:, AFS750-30-:-:, Made in Sweden CCC Declaration of Conformity, Contactor, AF580, AF750, Made in China |
| Declaration of Conformity – CE: | CE Declaration of Conformity – Contactor – AF400…AF2850 |
| Declaration of Conformity – UKCA: | UK Declaration of Conformity – Contactors >100A |
| DNV Certificate: | DNV_E-10966 |
| DNV GL Certificate: | DNV Certificate, Contactor, AF400…AF2850 |
| EAC Certificate: | 9AKK107046A8618 |
| GL Certificate: | GL_42988-02HH |
| LOVAG Certificate: | SE-0151293 |
| LR Certificate: | Lloyds register Certificate, Contactor, AF400…AF2850 |
| PRS Certificate: | PRS Certificate – AF116…AF1650 |
| RINA Certificate: | RINA Certificate, AF95, AF110, AF145, AF185, AF210, AF260, AF300, AF400, AF460, AF580, AF750, AF1250, AF1350, AF1650, AF2050, AF2650, AF116, AF140, AF146, AF190, AF205, AF265, AF305, AF370 |
| RMRS Certificate: | 9AKK107045A6978 |
| UL Certificate: | cULus Certificate, Contactor, AF580, AF750, AFS580, AFS750 |
| UL Listing Card: | UL_E36588 |
| Container Information | |
| Package Level 1 Units: | box 1 piece |
| Package Level 1 Width: | 280 mm |
| Package Level 1 Depth / Length: | 375 mm |
| Package Level 1 Height: | 310 mm |
| Package Level 1 Gross Weight: | 15 kg |
| Package Level 1 EAN: | 7320500220399 |
| External Classifications and Standards | |
| Object Classification Code: | Q |
| ETIM 7: | EC000066 – Power contactor, AC switching |
| ETIM 8: | EC000066 – Power contactor, AC switching |
| ETIM 9: | EC000066 – Power contactor, AC switching |
| eClass: | V11.0 : 27371003 |
| UNSPSC: | 39121529 |
| IDEA Granular Category Code (IGCC): | 4758 >> Iec Contactors |
| E-Number (Norway): | 4115298 |
| E-Number (Sweden): | 3228362 |