ABB AF140-40-00-12 48-130V50/60HZ-DC Contactor

General Information

Extended Product Type: AF140-40-00-12
Product ID: 1SFL447101R1200
EAN: 7320500505335
Catalog Description: AF140-40-00-12 Contactor
Long Description: The AF140-40-00-12 is a 4 pole – 690 V IEC or 600 V UL contactor with double clamp, controlling motors up to 75 kW / 400 V AC (AC-3) / and switching power circuits up to 200 A (AC-1) or 175 A UL general use. Thanks to the AF technology, the contactor has a wide control voltage range (48-130 V 50/60…Show moreHz and DC), managing large control voltage variations, reducing panel energy consumptions and ensuring distinct operations in unstable networks. Furthermore, surge protection is built-in, offering a compact solution. AF contactors have a block type design, can be easily extended with add-on auxiliary contact blocks and an additional wide range of accessories.Show less
SKU: 89ce9a498650 Categories: ,

Description

Ordering
Minimum Order Quantity: 1 piece
Customs Tariff Number: 85364900
Popular Downloads
Data Sheet, Technical Information: 1SBC100214C0202 – Main catalog Motor protection and control Manual motor starters, contactors and overload relays (PDF) – Edition 2024
Instructions and Manuals: Operating instruction, Contactor, AF(S)116, AF140, AF(S)146
CAD Dimensional Drawing: Information – 2D and 3D files for CAD systems
Dimension Diagram: Dimension Drawing. Contactor,AF116,AF140,AF146
Dimensions
Product Net Width: 120 mm
Product Net Depth / Length: 128 mm
Product Net Height: 150 mm
Product Net Weight: 2.05 kg
Technical
Number of Main Contacts NO: 4
Number of Main Contacts NC: 0
Number of Auxiliary Contacts NO: 0
Number of Auxiliary Contacts NC: 0
Number of Poles: 4P
Rated Operational Voltage: Main Circuit 690 V
Rated Frequency (f): Main Circuit 60 Hz
Conventional Free-air Thermal Current (Ith): acc. to IEC 60947-4-1, Open Contactors Θ = 40 °C 200 A
Rated Operational Current AC-1 (Ie): (690 V) 40 °C 200 A
(690 V) 60 °C 175 A
(690 V) 70 °C 160 A
Rated Operational Current AC-3 (Ie): (415 V) 55 °C 140 A
(440 V) 55 °C 140 A
(380 / 400 V) 55 °C 140 A
(220 / 230 / 240 V) 55 °C 140 A
Rated Operational Power AC-3 (Pe): (415 V) 75 kW
(440 V) 90 kW
(380 / 400 V) 75 kW
(220 / 230 / 240 V) 37 kW
Rated Breaking Capacity AC-3: 8 x Ie AC-3
Rated Making Capacity AC-3: 10 x Ie AC-3
Short-Circuit Protective Devices: gG Type Fuses 250 A
Rated Short-time Withstand Current Low Voltage (Icw): at 40 °C Ambient Temp, in Free Air, from a Cold State 10 s 1168 A
at 40 °C Ambient Temp, in Free Air, from a Cold State 15 min 200 A
at 40 °C Ambient Temp, in Free Air, from a Cold State 1 min 477 A
at 40 °C Ambient Temp, in Free Air, from a Cold State 1 s 1460 A
at 40 °C Ambient Temp, in Free Air, from a Cold State 30 s 674 A
Maximum Breaking Capacity: cos phi=0.45 (cos phi=0.35 for Ie > 100 A) at 440 V 3000 A
Rated Insulation Voltage (Ui): acc. to IEC 60947-4-1 and VDE 0110 (Gr. C) 1000 V
acc. to UL/CSA 600 V
Rated Impulse Withstand Voltage (Uimp): Main Circuit 8 kV
Maximum Electrical Switching Frequency: (AC-1) 300 cycles per hour
Mechanical Durability: 5 million
Maximum Mechanical Switching Frequency: 300 cycles per hour
Coil Operating Limits: (acc. to IEC 60947-4-1) 0.85 x Uc Min. … 1.1 x Uc Max. (at θ ≤ 70 °C)
Rated Control Circuit Voltage (Uc): 50 Hz 48 … 130 V
60 Hz 48 … 130 V
DC Operation 48 … 130 V
Coil Consumption: Holding at Max. Rated Control Circuit Voltage 50 Hz 4 V·A
Holding at Max. Rated Control Circuit Voltage 60 Hz 4 V·A
Holding at Max. Rated Control Circuit Voltage DC 2.5 W
Pull-in at Max. Rated Control Circuit Voltage 50 Hz 180 V·A
Pull-in at Max. Rated Control Circuit Voltage 60 Hz 180 V·A
Pull-in at Max. Rated Control Circuit Voltage DC 150 W
Power Loss: 18 W
at Rated Operating Conditions per Pole 18 W
Operate Time: Between Coil De-energization and NO Contact Opening 40 … 70 ms
Between Coil Energization and NO Contact Closing 20 … 55 ms
Connecting Capacity Main Circuit: Flexible 2 x 10 … 70 mm²
Rigid Cu-Cable 2 x 10 … 95 mm²
Connecting Capacity Auxiliary Circuit: Flexible with Ferrule 1x 0.75 … 2.5 mm²
Flexible with Insulated Ferrule 2x 0.75 … 2.5 mm²
Flexible 2×0.75 … 2.5 mm²
Solid 2 x 1 … 4 mm²
Stranded 2 x 1 …. 4 mm²
Degree of Protection: acc. to IEC 60529, IEC 60947-1, EN 60529 Coil Terminals IP20
acc. to IEC 60529, IEC 60947-1, EN 60529 Main Terminals IP00
Tightening Torque: Cable Lug 9 N·m
Main Circuit 8 N·m
Terminal Type: Double Clamp
Product Name: Block Contactor
Technical UL/CSA
NEMA Size: 4
Horsepower Rating NEMA: (200 V AC) Three Phase 40 Hp
(230 V AC) Three Phase 50 Hp
(460 V AC) Three Phase 100 Hp
(575 V AC) Three Phase 100 Hp
Maximum Operating Voltage UL/CSA: Main Circuit 600 V
General Use Rating UL/CSA: (600 V AC) 200 A
Horsepower Rating UL/CSA: (200 … 208 V AC) Three Phase 15 Hp
(200 V AC) Three Phase 40 hp
(208 V AC) Three Phase 40 hp
(220 … 240 V AC) Three Phase 20 Hp
(220 … 240 V AC) Three Phase 50 hp
(440 … 480 V AC) Three Phase 40 Hp
(440 … 480 V AC) Three Phase 100 hp
(550 … 600 V AC) Three Phase 50 Hp
(550 … 600 V AC) Three Phase 125 hp
Environmental
Ambient Air Temperature: Close to Contactor Fitted with Thermal O/L Relay (0.85 … 1.1 Uc) -25 … 50 °C
Close to Contactor without Thermal O/L Relay (0.85 … 1.1 Uc) -40 … 70 °C
Close to Contactor for Storage -40 … 70 °C
Maximum Operating Altitude Permissible: Without Derating 3000 m
Material Compliance
Conflict Minerals Reporting Template (CMRT): CMRT – Conflict Minerals Reporting Template
REACH Declaration: REACH – Letter of Confirmation for block contactors, contactor relays, installation contactors, mini contactors, mini contactor relays, thermal overload relays, electronic overload relays and related accessories
RoHS Information: RoHS II declaration for block contactors, installation contactors, mini contactors, mini contactor relays, thermal overload relays, electronic overload relays and related accessories
RoHS Status: Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019
Toxic Substances Control Act – TSCA: Toxic Substances Control Act (TSCA) declaration for Contactors
WEEE B2C / B2B: Business To Business
WEEE Category: 5. Small Equipment (No External Dimension More Than 50 cm)
ABB EcoSolutions
ABB EcoSolutions: Yes
ABB Site Meeting Group Waste To Landfill Target: Non-hazardous waste is sent to a landfill, where there is no alternative option available within 100km of a facility
End Of Life Disassembling Instructions: End-of-life instruction – AF(S)116(B)-::(RT) to AF(S)205(B)-::(RT)
Environmental Product Declaration – EPD: Environmental Product Declaration, AF(S)116-AF(S)146 (SE) Contactors
Improved Energy Efficiency for Customers: Product Efficiency – Product requires less energy to operate compared to similar product on market or older products from the same line
Recyclability Rate of the Product acc. to EN45555: Design for Closing Resource Loops – Standard EN45555 – 87.8 %
Sustainable Material Content in Product (wt. %): Recycled Metal – 37 %
Certificates and Declarations
ABS Certificate: ABS Approval, Contactor, AF116 … AF370 (Sweden)
BV Certificate: BV Certificate, Contactor, AF116-30 … AF370-30…AF116-40…AF370-40
CB Certificate: SEMKO_SE-77317
CQC Certificate: CQC Certificate, AC Contactor, AF116-:-:-:, AF140-:-:-:, AF146-:-:-:, AF116B-:-:-:, AF140B-:-:-:, AF146B-:-:-:, AFS116-30-:-:,AFS140-30-:-:, AFS146-30-:-:, Made in Sweden
Declaration of Conformity – CCC: CCC Declaration of Conformity, AC Contactor, AF116-:-:-:, AF140-:-:-:, AF146-:-:-:, AF116B-:-:-:, AF140B-:-:-:, AF146B-:-:-:, AFS116-30-:-:,AFS140-30-:-:, AFS146-30-:-:, Made in Sweden
Declaration of Conformity – CE: CE Declaration of Conformity – Contactor – AF116B…RT to AF370B…RT
Declaration of Conformity – UKCA: UK Declaration of Conformity – Contactors >100A
DNV GL Certificate: DNV-certificate, Contactors, AF116-30…AF370-30 and AF116-40…AF370-40
EAC Certificate: 9AKK107046A8618
KC Certificate: KC Certificate, Contactor, AF116-40…AF140-40 (Sweden)
LR Certificate: Lloyds register Certificate, Contactor, AF116-30 … AF370-30, AF116-40…AF370-40
PRS Certificate: PRS Certificate – AF116…AF1650
RINA Certificate: RINA Certificate, AF95, AF110, AF145, AF185, AF210, AF260, AF300, AF400, AF460, AF580, AF750, AF1250, AF1350, AF1650, AF2050, AF2650, AF116, AF140, AF146, AF190, AF205, AF265, AF305, AF370
RMRS Certificate: 9AKK107045A6978
UL Certificate: cULus Certificate, Contactor, AF116-40, AF140-40 (4-pole)
Container Information
Package Level 1 Units: box 1 piece
Package Level 1 Width: 147 mm
Package Level 1 Depth / Length: 197 mm
Package Level 1 Height: 155 mm
Package Level 1 Gross Weight: 2.25 kg
Package Level 1 EAN: 7320500505335
External Classifications and Standards
Object Classification Code: Q
ETIM 7: EC000066 – Power contactor, AC switching
ETIM 8: EC000066 – Power contactor, AC switching
ETIM 9: EC000066 – Power contactor, AC switching
eClass: V11.0 : 27371003
UNSPSC: 39121529
IDEA Granular Category Code (IGCC): 4758 >> Iec Contactors
E-Number (Finland): 3706084

Downloads