Description
| Ordering | |
| Minimum Order Quantity: | 1 piece |
| Popular Downloads | |
| Data Sheet, Technical Information: | 1SBC100214C0202 – Main catalog Motor protection and control Manual motor starters, contactors and overload relays (PDF) – Edition 2024 |
| Instructions and Manuals: | Installation instructions AF(C)40(B)…80(B)-40/22 Contactors, CA4, CAL4, CAT4, CC4, LDC4 Accessories |
| CAD Dimensional Drawing: | Information – 2D and 3D files for CAD systems |
| Dimensions | |
| Product Net Width: | 70 mm |
| Product Net Depth / Length: | 113.5 mm |
| Product Net Height: | 125.5 mm |
| Product Net Weight: | 1.21 kg |
| Technical | |
| Number of Main Contacts NO: | 4 |
| Number of Main Contacts NC: | 0 |
| Number of Auxiliary Contacts NO: | 0 |
| Number of Auxiliary Contacts NC: | 0 |
| Number of Poles: | 4P |
| Standards: | IEC/EN 60947-1, IEC/EN 60947-4-1, UL 60335-2-40 LZGH2 A2L, UL 60947-1, UL 60947-4-1, CSA C22.2 No. 60335-2-40 LZGH2 A2L, CSA C22.2 No. 60947-1:22, CSA C22.2 No. 60947-4-1:22 |
| Rated Operational Voltage: | Main Circuit 690 V |
| Rated Frequency (f): | Control Circuit 50 / 60 Hz Main Circuit 50 / 60 Hz |
| Conventional Free-air Thermal Current (Ith): | acc. to IEC 60947-4-1, Open Contactors Θ = 40 °C 105 A |
| Rated Operational Current AC-1 (Ie): | (690 V) 40 °C 100 A (690 V) 60 °C 80 A (690 V) 70 °C 70 A |
| Rated Operational Current AC-3 (Ie): | (415 V) 60 °C 53 A (440 V) 60 °C 53 A (500 V) 60 °C 45 A (690 V) 60 °C 35 A (380 / 400 V) 60 °C 53 A (220 / 230 / 240 V) 60 °C 53 A |
| Rated Operational Power AC-3 (Pe): | (415 V) 30 kW (440 V) 30 kW (500 V) 30 kW (690 V) 30 kW (380 / 400 V) 22 kW (220 / 230 / 240 V) 15 kW |
| Rated Short-time Withstand Current Low Voltage (Icw): | at 40 °C Ambient Temp, in Free Air, from a Cold State 10 s 600 A at 40 °C Ambient Temp, in Free Air, from a Cold State 15 min 110 A at 40 °C Ambient Temp, in Free Air, from a Cold State 1 min 250 A at 40 °C Ambient Temp, in Free Air, from a Cold State 1 s 1000 A at 40 °C Ambient Temp, in Free Air, from a Cold State 30 s 350 A |
| Maximum Breaking Capacity: | cos phi=0.45 (cos phi=0.35 for Ie > 100 A) at 440 V 950 A cos phi=0.45 (cos phi=0.35 for Ie > 100 A) at 690 V 600 A |
| Rated Insulation Voltage (Ui): | acc. to IEC 60947-4-1 690 V acc. to UL/CSA 600 V |
| Rated Impulse Withstand Voltage (Uimp): | 6 kV |
| Maximum Electrical Switching Frequency: | (AC-1) 600 cycles per hour |
| Maximum Mechanical Switching Frequency: | 3600 cycles per hour |
| Rated Control Circuit Voltage (Uc): | 50 Hz 24 … 60 V 60 Hz 24 … 60 V DC Operation 20 … 60 V |
| Coil Consumption: | Average Holding Value 50 / 60 Hz 4 V·A Average Holding Value 50 Hz 4 V·A Average Holding Value 60 Hz 4 V·A Average Holding Value DC 2 W Average Holding Value, from Warm State 2 W |
| Power Loss: | at Rated Operating Conditions AC-1 per Pole 6.3 W at Rated Operating Conditions AC-3 per Pole 1.7 W |
| Mounting on DIN Rail: | TH35-15 (35 x 15 mm Mounting Rail) acc. to IEC 60715 |
| Mounting by Screws (not supplied): | 2 x M4 or 2 x M6 screws placed diagonally |
| Connecting Capacity Main Circuit: | Flexible with Ferrule 1/2x 4 … 35 mm² Flexible with Insulated Ferrule 1/2x 4 … 35 mm² Rigid Stranded 1/2x 6 … 35 mm² |
| Connecting Capacity Control Circuit: | Flexible with Ferrule 1/2x 0.75 … 2.5 mm² Flexible with Insulated Ferrule 1x 0.75 … 2.5 mm² Flexible with Insulated Ferrule 2x 0.75 … 1.5 mm² Rigid Solid 1/2x 1 … 2.5 mm² Rigid Stranded 1/2x 1 … 2.5 mm² |
| Wire Stripping Length: | Control Circuit 10 mm Main Circuit 16 mm |
| Degree of Protection: | acc. to IEC 60529, IEC 60947-1, EN 60529 Coil Terminals IP20 acc. to IEC 60529, IEC 60947-1, EN 60529 Main Terminals IP10 |
| Recommended Screw Driver: | Pozidriv PZ |
| Tightening Torque: | Control Circuit 1.2 N·m Main Circuit 4 N·m |
| Terminal Type: | Screw Terminals |
| Product Name: | Block Contactor |
| Technical UL/CSA | |
| Maximum Operating Voltage UL/CSA: | Main Circuit 600 V |
| General Use Rating UL/CSA: | (600 V AC) 80 A |
| Connecting Capacity Main Circuit UL/CSA: | Rigid Stranded 1/2x 10-2 AWG |
| Connecting Capacity Control Circuit UL/CSA: | Rigid Solid 1/2x 18-14 AWG Rigid Stranded 1/2x 18-14 AWG |
| Tightening Torque UL/CSA: | Control Circuit 11 in·lb Main Circuit 35 in·lb |
| Full Load Amps Motor Use: | (120 V AC) Single Phase 3 A (200 … 208 V AC) Three Phase 15 A (220 … 240 V AC) Three Phase 20 A (240 V AC) Single Phase 10 A (440 … 480 V AC) Three Phase 40 A (550 … 600 V AC) Three Phase 50 A |
| Environmental | |
| Ambient Air Temperature: | Close to Contactor for Storage -60 … +80 °C Near Contactor for Operation in Free Air -40 … 70 °C |
| Climatic Withstand: | Category B according to IEC 60947-1 Annex Q |
| Maximum Operating Altitude Permissible: | Without Derating 3000 m |
| Resistance to Vibrations: | 3g Closed Position & 2g Open Position 5 … 300 Hz |
| Pollution Degree: | 3 |
| Material Compliance | |
| Conflict Minerals Reporting Template (CMRT): | CMRT – Conflict Minerals Reporting Template |
| REACH Declaration: | REACH – Letter of Confirmation for block contactors, contactor relays, installation contactors, mini contactors, mini contactor relays, thermal overload relays, electronic overload relays and related accessories |
| RoHS Information: | RoHS II declaration for block contactors, installation contactors, mini contactors, mini contactor relays, thermal overload relays, electronic overload relays and related accessories |
| RoHS Status: | Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019 |
| Toxic Substances Control Act – TSCA: | Toxic Substances Control Act (TSCA) declaration for Contactors |
| WEEE B2C / B2B: | Business To Business |
| WEEE Category: | 5. Small Equipment (No External Dimension More Than 50 cm) |
| ABB EcoSolutions | |
| ABB EcoSolutions: | Yes |
| End Of Life Disassembling Instructions: | End of life instruction AF(S)40/52/65/80/96(B)(RT) Contactors |
| Environmental Product Declaration – EPD: | Environmental Product Declaration AF40, AF52, AF65 (CN) Environmental Product Declaration AF(S)40(B), AF(S)52(B), AF(S)65(B) (FR) |
| Sustainable Material Content in Packaging (wt. %): | FSC Recycled Paper – 94.6 % |
| Sustainable Material Content in Product (wt. %): | Recycled Metal – 28.2 % |
| Certificates and Declarations | |
| A2L Certificate – UL: | 9AKK108469A4890;9AKK108469A4892 |
| ABS Certificate: | ABS Certificate, AF(S)09 to AF(S)96 contactors, NF contactor relays and CA4, CC4, CAL4, CAT4 auxiliary contact blocks, TEF4 electronic timers |
| BV Certificate: | BV_2634H36994B1 |
| CB Certificate: | CB Certificate AF(S)40(B), (S)AF52(B), AF(S)65(B) 3 and 4-pole contactors |
| CCC Certificate: | CQC Certificate, Contactor, AF:40-30-::-::, AF40-40-::-::, AF40-22-::-::, AF:52-30-::-::, AF52-40-::-::,AF:65-30-::-::, Made in France |
| CQC Certificate: | CQC Certificate, Contactor, AF:40-30-::-::, AF40-40-::-::, AF40-22-::-::, AF:52-30-::-::, AF52-40-::-::,AF:65-30-::-::, Made in France |
| Declaration of Conformity – CCC: | CCC Declaration of Conformity, Contactor, AF:40-30-::-::, AF40-40-::-::, AF40-22-::-::, AF:52-30-::-::, AF52-40-::-::,AF:65-30-::-::, Made in France |
| Declaration of Conformity – CE: | EU Declaration of Conformity AF09, AF16, AF26, AF38, AF40, AF52, AF80, 4-pole Contactors |
| Declaration of Conformity – UKCA: | UK Declaration of Conformity AF09, AF16, AF26, AF38, AF40, AF52, AF80, 4-pole Contactors |
| DNV Certificate: | DNV Certificate AF(S)09…96 3-pole & AF09…80 4-pole contactors with screw, spring, push-in terminals |
| KC Certificate: | KC Certificate AF52 4-pole Contactors |
| LR Certificate: | LRS Certificate AF(S)09..(K) … AF96 3 and 4-pole contactors and CA(L)4..(K), CAT4, CC4 auxiliary contact blocks |
| RMRS Certificate: | RMRS Certificate AF09(S)…AF38 3-pole and 4-pole, AF40..96 3-pole contactors, screw and spring terminals |
| UL Certificate: | UL-US Certificate of Compliance AF40(B)…80(B) 4-pole contactors UL-CA Certificate of Compliance AF40(B)…80(B) 4-pole contactors |
| UL Listing Card: | UL_E312527 |
| Container Information | |
| Package Level 1 Units: | box 1 piece |
| Package Level 1 Width: | 150 mm |
| Package Level 1 Depth / Length: | 150 mm |
| Package Level 1 Height: | 103 mm |
| Package Level 1 Gross Weight: | 1.32 kg |
| Package Level 1 EAN: | 3471523133617 |
| Package Level 2 Units: | box 8 piece |
| Package Level 2 Width: | 250 mm |
| Package Level 2 Depth / Length: | 300 mm |
| Package Level 2 Height: | 300 mm |
| Package Level 2 Gross Weight: | 10.56 kg |
| Package Level 3 Units: | 192 piece |
| External Classifications and Standards | |
| Object Classification Code: | Q |
| ETIM 7: | EC000066 – Power contactor, AC switching |
| ETIM 8: | EC000066 – Power contactor, AC switching |
| ETIM 9: | EC000066 – Power contactor, AC switching |
| eClass: | V11.0 : 27371003 |
| UNSPSC: | 39121529 |
| IDEA Granular Category Code (IGCC): | 4758 >> Iec Contactors |
| E-Number (Finland): | 3707260 |
| E-Number (Sweden): | 3210309 |