ABB AF52-40-00-13 100-250V50/60HZ-DC Contactor

General Information

Extended Product Type: AF52-40-00-13
Product ID: 1SBL367201R1300
EAN: 3471523133631
Catalog Description: AF52-40-00-13 100-250V50/60HZ-DC Contactor
Long Description: The AF52-40-00-13 is a 4 pole – 690 V IEC or 600 UL contactor with screw terminals, controlling motors up to 22 kW / 400 V AC (AC-3) and switching power circuits up to 100 A (AC-1) or 80 A UL general use. Thanks to the AF technology, the contactor has a wide control voltage range (100-250 V 50/60 Hz…Show moreand DC), managing large control voltage variations, reducing panel energy consumptions and ensuring distinct operations in unstable networks. Furthermore, surge protection is built-in, offering a compact solution. AF contactors have a block type design, can be easily extended with add-on auxiliary contact blocks and an additional wide range of accessories.Show less
SKU: 941a6daaee10 Categories: ,

Description

Ordering
Minimum Order Quantity: 1 piece
Popular Downloads
Data Sheet, Technical Information: 1SBC100214C0202 – Main catalog Motor protection and control Manual motor starters, contactors and overload relays (PDF) – Edition 2024
Instructions and Manuals: Installation instructions AF(C)40(B)…80(B)-40/22 Contactors, CA4, CAL4, CAT4, CC4, LDC4 Accessories
CAD Dimensional Drawing: Information – 2D and 3D files for CAD systems
Dimensions
Product Net Width: 70 mm
Product Net Depth / Length: 113.5 mm
Product Net Height: 125.5 mm
Product Net Weight: 1.16 kg
Technical
Number of Main Contacts NO: 4
Number of Main Contacts NC: 0
Number of Auxiliary Contacts NO: 0
Number of Auxiliary Contacts NC: 0
Number of Poles: 4P
Standards: IEC/EN 60947-1, IEC/EN 60947-4-1, UL 60335-2-40 LZGH2 A2L, UL 60947-1, UL 60947-4-1, CSA C22.2 No. 60335-2-40 LZGH2 A2L, CSA C22.2 No. 60947-1:22, CSA C22.2 No. 60947-4-1:22
Rated Operational Voltage: Main Circuit 690 V
Rated Frequency (f): Control Circuit 50 / 60 Hz
Main Circuit 50 / 60 Hz
Conventional Free-air Thermal Current (Ith): acc. to IEC 60947-4-1, Open Contactors Θ = 40 °C 105 A
Rated Operational Current AC-1 (Ie): (690 V) 40 °C 100 A
(690 V) 60 °C 80 A
(690 V) 70 °C 70 A
Rated Operational Current AC-3 (Ie): (415 V) 60 °C 53 A
(440 V) 60 °C 53 A
(500 V) 60 °C 45 A
(690 V) 60 °C 35 A
(380 / 400 V) 60 °C 53 A
(220 / 230 / 240 V) 60 °C 53 A
Rated Operational Power AC-3 (Pe): (415 V) 30 kW
(440 V) 30 kW
(500 V) 30 kW
(690 V) 30 kW
(380 / 400 V) 22 kW
(220 / 230 / 240 V) 15 kW
Rated Short-time Withstand Current Low Voltage (Icw): at 40 °C Ambient Temp, in Free Air, from a Cold State 10 s 600 A
at 40 °C Ambient Temp, in Free Air, from a Cold State 15 min 110 A
at 40 °C Ambient Temp, in Free Air, from a Cold State 1 min 250 A
at 40 °C Ambient Temp, in Free Air, from a Cold State 1 s 1000 A
at 40 °C Ambient Temp, in Free Air, from a Cold State 30 s 350 A
Maximum Breaking Capacity: cos phi=0.45 (cos phi=0.35 for Ie > 100 A) at 440 V 950 A
cos phi=0.45 (cos phi=0.35 for Ie > 100 A) at 690 V 600 A
Rated Insulation Voltage (Ui): acc. to IEC 60947-4-1 690 V
acc. to UL/CSA 600 V
Rated Impulse Withstand Voltage (Uimp): 6 kV
Maximum Electrical Switching Frequency: (AC-1) 600 cycles per hour
Maximum Mechanical Switching Frequency: 3600 cycles per hour
Rated Control Circuit Voltage (Uc): 50 Hz 100 … 250 V
60 Hz 100 … 250 V
DC Operation 100 … 250 V
Coil Consumption: Average Holding Value 50 / 60 Hz 4 V·A
Average Holding Value 50 Hz 4 V·A
Average Holding Value 60 Hz 4 V·A
Average Holding Value DC 2 W
Average Holding Value, from Warm State 2 W
Power Loss: at Rated Operating Conditions AC-1 per Pole 6.3 W
at Rated Operating Conditions AC-3 per Pole 1.7 W
Mounting on DIN Rail: TH35-15 (35 x 15 mm Mounting Rail) acc. to IEC 60715
Mounting by Screws (not supplied): 2 x M4 or 2 x M6 screws placed diagonally
Connecting Capacity Main Circuit: Flexible with Ferrule 1/2x 4 … 35 mm²
Flexible with Insulated Ferrule 1/2x 4 … 35 mm²
Rigid Stranded 1/2x 6 … 35 mm²
Connecting Capacity Control Circuit: Flexible with Ferrule 1/2x 0.75 … 2.5 mm²
Flexible with Insulated Ferrule 1x 0.75 … 2.5 mm²
Flexible with Insulated Ferrule 2x 0.75 … 1.5 mm²
Rigid Solid 1/2x 1 … 2.5 mm²
Rigid Stranded 1/2x 1 … 2.5 mm²
Wire Stripping Length: Control Circuit 10 mm
Main Circuit 16 mm
Degree of Protection: acc. to IEC 60529, IEC 60947-1, EN 60529 Coil Terminals IP20
acc. to IEC 60529, IEC 60947-1, EN 60529 Main Terminals IP10
Recommended Screw Driver: Pozidriv PZ
Tightening Torque: Control Circuit 1.2 N·m
Main Circuit 4 N·m
Terminal Type: Screw Terminals
Product Name: Block Contactor
Technical UL/CSA
Maximum Operating Voltage UL/CSA: Main Circuit 600 V
General Use Rating UL/CSA: (600 V AC) 80 A
Connecting Capacity Main Circuit UL/CSA: Rigid Stranded 1/2x 10-2 AWG
Connecting Capacity Control Circuit UL/CSA: Rigid Solid 1/2x 18-14 AWG
Rigid Stranded 1/2x 18-14 AWG
Tightening Torque UL/CSA: Control Circuit 11 in·lb
Main Circuit 35 in·lb
Full Load Amps Motor Use: (120 V AC) Single Phase 3 A
(200 … 208 V AC) Three Phase 15 A
(220 … 240 V AC) Three Phase 20 A
(240 V AC) Single Phase 10 A
(440 … 480 V AC) Three Phase 40 A
(550 … 600 V AC) Three Phase 50 A
Environmental
Ambient Air Temperature: Close to Contactor for Storage -60 … +80 °C
Near Contactor for Operation in Free Air -40 … 70 °C
Climatic Withstand: Category B according to IEC 60947-1 Annex Q
Maximum Operating Altitude Permissible: Without Derating 3000 m
Resistance to Vibrations: 3g Closed Position & 2g Open Position 5 … 300 Hz
Pollution Degree: 3
Material Compliance
Conflict Minerals Reporting Template (CMRT): CMRT – Conflict Minerals Reporting Template
REACH Declaration: REACH – Letter of Confirmation for block contactors, contactor relays, installation contactors, mini contactors, mini contactor relays, thermal overload relays, electronic overload relays and related accessories
RoHS Information: RoHS II declaration for block contactors, installation contactors, mini contactors, mini contactor relays, thermal overload relays, electronic overload relays and related accessories
RoHS Status: Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019
SCIP: 6eea65c8-5f94-47c5-99d5-be4670b5a8ac France (FR)
Simplified SCIP: 9be8b062-dbca-49ee-897e-9f800b4e301f Germany (DE)
595a5625-2fce-4b28-8cd9-ec6e496adb12 Norway (NO)
3b66d278-56f5-4e8b-aafc-f9da2ab6e748 Hungary (HU)
06e45964-c279-4267-ad46-b43d299fa327 Estonia (EE)
88c281b6-f549-4257-b4f5-d91d5d13b827 Greece (GR)
d5f8634c-ab38-475d-bbe1-dcb93fb0fee0 Portugal (PT)
044d79b6-9de4-4a4e-bb6a-c8aa1833cff6 Bulgaria (BG)
68a55a60-0586-498f-919d-84512d164d7d Poland (PL)
3aa67de6-8e57-4342-9d85-4e21bce99cc9 Belgium (BE)
fb45f20c-361c-4c78-889f-12591fbdc846 Germany (DE)
b128d632-d83d-4cd3-a401-bb6c37370d79 Hungary (HU)
fe6fe32e-b8be-4258-9e82-922b6630c4fa Spain (ES)
f4eccf12-935e-4f8a-bbe7-5067954b2d8c Finland (FI)
d8242696-1b79-40a0-9761-1f66152866e2 Belgium (BE)
093f7b7b-e9cb-4e6b-a798-0164f4427ebf Italy (IT)
c3eda9e0-7d8e-42e4-b43c-2e65fea6ed82 Germany (DE)
5d300b9d-2b4f-4881-b46b-cf104fc9655b Denmark (DK)
47fa390f-1033-4bf8-bf92-cbb0dade84bf Germany (DE)
16ff3c0e-52c6-4cd8-94e8-7cdbf1cb196b Croatia (HR)
d7cc5d00-24bc-41c7-86c5-70fa887fcca9 Czech Republic (CZ)
102ac3a1-dab2-4a53-b91c-82abd36840ef Poland (PL)
170b1373-1d48-4e0a-9b8e-eb4c6a3aa63f Netherlands (NL)
ba55232b-fc3f-4aed-81c4-47f3167ea6f8 Sweden (SE)
580004b1-0a7a-463e-b192-eacdb4d9b7dc Poland (PL)
93d28930-4246-4f43-b946-483b03b119e2 France (FR)
80d3df0e-6bd3-46db-bfe1-9c0bc77d4b66 Sweden (SE)
2848fad5-b957-41d5-a16f-739dea097d3b Germany (DE)
Toxic Substances Control Act – TSCA: Toxic Substances Control Act (TSCA) declaration for Contactors
WEEE B2C / B2B: Business To Business
WEEE Category: 5. Small Equipment (No External Dimension More Than 50 cm)
ABB EcoSolutions
ABB EcoSolutions: Yes
End Of Life Disassembling Instructions: End of life instruction AF(S)40/52/65/80/96(B)(RT) Contactors
Environmental Product Declaration – EPD: Environmental Product Declaration AF40, AF52, AF65 (CN)
Environmental Product Declaration AF(S)40(B), AF(S)52(B), AF(S)65(B) (FR)
Sustainable Material Content in Packaging (wt. %): FSC Recycled Paper – 94.6 %
Sustainable Material Content in Product (wt. %): Recycled Metal – 28.2 %
Certificates and Declarations
A2L Certificate – UL: 9AKK108469A4890;9AKK108469A4892
ABS Certificate: ABS Certificate, AF(S)09 to AF(S)96 contactors, NF contactor relays and CA4, CC4, CAL4, CAT4 auxiliary contact blocks, TEF4 electronic timers
BV Certificate: BV_2634H36994B1
CB Certificate: CB Certificate AF(S)40(B), (S)AF52(B), AF(S)65(B) 3 and 4-pole contactors
CCC Certificate: CQC Certificate, Contactor, AF:40-30-::-::, AF40-40-::-::, AF40-22-::-::, AF:52-30-::-::, AF52-40-::-::,AF:65-30-::-::, Made in France
CQC Certificate: CQC Certificate, Contactor, AF:40-30-::-::, AF40-40-::-::, AF40-22-::-::, AF:52-30-::-::, AF52-40-::-::,AF:65-30-::-::, Made in France
Declaration of Conformity – CCC: CCC Declaration of Conformity, Contactor, AF:40-30-::-::, AF40-40-::-::, AF40-22-::-::, AF:52-30-::-::, AF52-40-::-::,AF:65-30-::-::, Made in France
Declaration of Conformity – CE: EU Declaration of Conformity AF09, AF16, AF26, AF38, AF40, AF52, AF80, 4-pole Contactors
Declaration of Conformity – UKCA: UK Declaration of Conformity AF09, AF16, AF26, AF38, AF40, AF52, AF80, 4-pole Contactors
DNV Certificate: DNV Certificate AF(S)09…96 3-pole & AF09…80 4-pole contactors with screw, spring, push-in terminals
KC Certificate: KC Certificate AF52 4-pole Contactors
LR Certificate: LRS Certificate AF(S)09..(K) … AF96 3 and 4-pole contactors and CA(L)4..(K), CAT4, CC4 auxiliary contact blocks
RMRS Certificate: RMRS Certificate AF09(S)…AF38 3-pole and 4-pole, AF40..96 3-pole contactors, screw and spring terminals
UL Certificate: UL-US Certificate of Compliance AF40(B)…80(B) 4-pole contactors
UL-CA Certificate of Compliance AF40(B)…80(B) 4-pole contactors
UL Listing Card: UL_E312527
Container Information
Package Level 1 Units: box 1 piece
Package Level 1 Width: 150 mm
Package Level 1 Depth / Length: 150 mm
Package Level 1 Height: 103 mm
Package Level 1 Gross Weight: 1.27 kg
Package Level 1 EAN: 3471523133631
Package Level 2 Units: box 8 piece
Package Level 2 Width: 250 mm
Package Level 2 Depth / Length: 300 mm
Package Level 2 Height: 300 mm
Package Level 2 Gross Weight: 10.16 kg
Package Level 3 Units: 192 piece
External Classifications and Standards
Object Classification Code: Q
ETIM 7: EC000066 – Power contactor, AC switching
ETIM 8: EC000066 – Power contactor, AC switching
ETIM 9: EC000066 – Power contactor, AC switching
eClass: V11.0 : 27371003
UNSPSC: 39121529
IDEA Granular Category Code (IGCC): 4758 >> Iec Contactors
E-Number (Finland): 3707262
E-Number (Sweden): 3210311

Downloads