Ordering | |
Minimum Order Quantity: | 1 piece |
Customs Tariff Number: | 85364900 |
Popular Downloads | |
Data Sheet, Technical Information: | 1SBC100214C0202 – Main catalog Motor protection and control Manual motor starters, contactors and overload relays (PDF) – Edition 2024 |
Instructions and Manuals: | Installation instructions AF(C)40(B)…96(B)-30 Contactors, CA4, CAL4, CAT4, CC4, LDC4 Accessories |
CAD Dimensional Drawing: | Information – 2D and 3D files for CAD systems |
Dimensions | |
Product Net Width: | 82 mm |
Product Net Depth / Length: | 116 mm |
Product Net Height: | 125.5 mm |
Product Net Weight: | 1.26 kg |
Technical | |
Number of Main Contacts NO: | 3 |
Number of Main Contacts NC: | 0 |
Number of Auxiliary Contacts NO: | 1 |
Number of Auxiliary Contacts NC: | 1 |
Number of Poles: | 3P |
Standards: | IEC/EN 60947-1, IEC/EN 60947-4-1, UL 60335-2-40 LZGH2 A2L, UL 60947-1, UL 60947-4-1, CSA C22.2 No. 60335-2-40 LZGH2 A2L, CSA C22.2 No. 60947-1:22, CSA C22.2 No. 60947-4-1:22 |
Rated Operational Voltage: | Auxiliary Circuit 690 V Main Circuit 1000 V |
Rated Frequency (f): | Auxiliary Circuit 50 / 60 Hz Control Circuit 50 / 60 Hz Main Circuit 50 / 60 Hz |
Conventional Free-air Thermal Current (Ith): | acc. to IEC 60947-4-1, Open Contactors Θ = 40 °C 130 A acc. to IEC 60947-5-1, Θ = 40 °C 16 A |
Rated Operational Current AC-1 (Ie): | (690 V) 40 °C 130 A (690 V) 60 °C 105 A (690 V) 70 °C 90 A |
Rated Operational Current AC-3 (Ie): | (415 V) 60 °C 96 A (440 V) 60 °C 96 A (500 V) 60 °C 80 A (690 V) 60 °C 57 A (1000 V) 60 °C 30 A (380 / 400 V) 60 °C 105 A (220 / 230 / 240 V) 60 °C 105 A |
Rated Operational Current AC-3e (Ie): | (415 V) 60 °C 96 A (440 V) 60 °C 96 A (500 V) 60 °C 80 A (690 V) 60 °C 57 A (380 / 400 V) 60 °C 105 A (220 / 230 / 240 V) 60 °C 105 A |
Rated Operational Current AC-15 (Ie): | (500 V) 2 A (690 V) 2 A (24 / 127 V) 6 A (220 / 240 V) 4 A (400 / 440 V) 3 A |
Rated Operational Current DC-1 (Ie): | (110 V) 2 Poles in Series, 40 °C 130 A (110 V) 2 Poles in Series, 60 °C 105 A (110 V) 2 Poles in Series, 70 °C 90 A (110 V) 3 Poles in Series, 40 °C 130 A (110 V) 3 Poles in Series, 60 °C 105 A (110 V) 3 Poles in Series, 70 °C 90 A (220 V) 3 Poles in Series, 40 °C 125 A (220 V) 3 Poles in Series, 60 °C 105 A (220 V) 3 Poles in Series, 70 °C 90 A (72 V) 1-Pole, 40 °C 130 A (72 V) 1-Pole, 60 °C 105 A (72 V) 1-Pole, 70 °C 90 A (72 V) 2 Poles in Series, 40 °C 130 A (72 V) 2 Poles in Series, 60 °C 105 A (72 V) 2 Poles in Series, 70 °C 90 A (72 V) 3 Poles in Series, 40 °C 130 A (72 V) 3 Poles in Series, 60 °C 105 A (72 V) 3 Poles in Series, 70 °C 90 A |
Rated Operational Current DC-3 (Ie): | (110 V) 2 Poles in Series, 40 °C 130 A (110 V) 2 Poles in Series, 60 °C 105 A (110 V) 2 Poles in Series, 70 °C 90 A (110 V) 3 Poles in Series, 40 °C 130 A (110 V) 3 Poles in Series, 60 °C 105 A (110 V) 3 Poles in Series, 70 °C 90 A (220 V) 3 Poles in Series, 40 °C 130 A (220 V) 3 Poles in Series, 60 °C 105 A (220 V) 3 Poles in Series, 70 °C 90 A (72 V) 1-Pole, 40 °C 130 A (72 V) 1-Pole, 60 °C 105 A (72 V) 1-Pole, 70 °C 90 A (72 V) 2 Poles in Series, 40 °C 130 A (72 V) 2 Poles in Series, 60 °C 105 A (72 V) 2 Poles in Series, 70 °C 90 A (72 V) 3 Poles in Series, 40 °C 130 A (72 V) 3 Poles in Series, 60 °C 105 A (72 V) 3 Poles in Series, 70 °C 90 A |
Rated Operational Current DC-5 (Ie): | (110 V) 2 Poles in Series, 40 °C 130 A (110 V) 2 Poles in Series, 60 °C 105 A (110 V) 2 Poles in Series, 70 °C 90 A (110 V) 3 Poles in Series, 40 °C 130 A (110 V) 3 Poles in Series, 60 °C 105 A (110 V) 3 Poles in Series, 70 °C 90 A (220 V) 3 Poles in Series, 40 °C 130 A (220 V) 3 Poles in Series, 60 °C 105 A (220 V) 3 Poles in Series, 70 °C 90 A (72 V) 1-Pole, 40 °C 130 A (72 V) 1-Pole, 60 °C 105 A (72 V) 1-Pole, 70 °C 90 A (72 V) 2 Poles in Series, 40 °C 130 A (72 V) 2 Poles in Series, 60 °C 105 A (72 V) 2 Poles in Series, 70 °C 90 A (72 V) 3 Poles in Series, 40 °C 130 A (72 V) 3 Poles in Series, 60 °C 105 A (72 V) 3 Poles in Series, 70 °C 90 A |
Rated Operational Current DC-13 (Ie): | (24 V) 6 A / 144 W (48 V) 2.8 A / 134 W (72 V) 1 A / 72 W (110 V) 0.55 A / 60 W (125 V) 0.55 A / 69 W (220 V) 0.27 A / 60 W (250 V) 0.27 A / 68 W (400 V) 0.15 A / 60 W (500 V) 0.13 A / 65 W (600 V) 0.1 A / 60 W |
Rated Operational Power AC-3 (Pe): | (415 V) 55 kW (440 V) 55 kW (500 V) 55 kW (690 V) 55 kW (1000 V) 40 kW (380 / 400 V) 45 kW (380 / 400 V) 55 kW (220 / 230 / 240 V) 25 kW (220 / 230 / 240 V) 30 kW |
Rated Operational Power AC-3e (Pe): | (415 V) 55 kW (440 V) 55 kW (500 V) 55 kW (690 V) 55 kW (380 / 400 V) 45 kW (380 / 400 V) 55 kW (220 / 230 / 240 V) 25 kW (220 / 230 / 240 V) 30 kW |
Rated Short-time Withstand Current Low Voltage (Icw): | at 40 °C Ambient Temp, in Free Air, from a Cold State 10 s 840 A at 40 °C Ambient Temp, in Free Air, from a Cold State 15 min 140 A at 40 °C Ambient Temp, in Free Air, from a Cold State 1 min 300 A at 40 °C Ambient Temp, in Free Air, from a Cold State 1 s 1200 A at 40 °C Ambient Temp, in Free Air, from a Cold State 30 s 450 A for 0.1 s 140 A for 1 s 100 A |
Maximum Breaking Capacity: | cos phi=0.45 (cos phi=0.35 for Ie > 100 A) at 440 V 1150 A cos phi=0.45 (cos phi=0.35 for Ie > 100 A) at 690 V 750 A |
Rated Insulation Voltage (Ui): | acc. to IEC 60947-4-1 1000 V acc. to IEC 60947-5-1 690 V acc. to UL/CSA 600 V |
Rated Impulse Withstand Voltage (Uimp): | 8 kV |
Maximum Electrical Switching Frequency: | (AC-1) 600 cycles per hour (AC-15) 1200 cycles per hour (AC-2 / AC-4) 150 cycles per hour (AC-3) 1200 cycles per hour (DC-13) 900 cycles per hour |
Maximum Mechanical Switching Frequency: | 3600 cycles per hour |
Rated Control Circuit Voltage (Uc): | 50 Hz 24 … 60 V 60 Hz 24 … 60 V DC Operation 20 … 60 V |
Coil Consumption: | Average Holding Value 50 / 60 Hz 4 V·A Average Holding Value 50 Hz 4 V·A Average Holding Value 60 Hz 4 V·A Average Holding Value DC 2 W Average Holding Value, from Warm State 2 W |
Power Loss: | at 6 A per Pole 0.1 W at Rated Operating Conditions AC-1 per Pole 8.2 W at Rated Operating Conditions AC-3 per Pole 4.5 W |
Operate Time: | Between Coil De-energization and NC Contact Closing 19 … 105 ms Between Coil De-energization and NO Contact Opening 17 … 100 ms Between Coil Energization and NC Contact Opening 38 … 95 ms Between Coil Energization and NO Contact Closing 42 … 100 ms |
Mounting on DIN Rail: | TH35-15 (35 x 15 mm Mounting Rail) acc. to IEC 60715 |
Mounting by Screws (not supplied): | 2 x M4 or 2 x M6 screws placed diagonally |
Connecting Capacity Main Circuit: | Flexible with Ferrule 1/2x 6 … 50 mm² Flexible with Insulated Ferrule 1/2x 6 … 50 mm² Rigid Stranded 1x 6 … 70 mm² Rigid Stranded 2x 6 … 50 mm² |
Connecting Capacity Auxiliary Circuit: | Flexible with Ferrule 1/2x 0.75 … 2.5 mm² Flexible with Insulated Ferrule 2x 0.75 … 1.5 mm² Flexible with Insulated Ferrule 1x 0.75 … 2.5 mm² Rigid 1/2x 1 … 2.5 mm² |
Connecting Capacity Control Circuit: | Flexible with Ferrule 1/2x 0.75 … 2.5 mm² Flexible with Insulated Ferrule 1x 0.75 … 2.5 mm² Flexible with Insulated Ferrule 2x 0.75 … 1.5 mm² Rigid 1/2x 1 … 2.5 mm² |
Wire Stripping Length: | Auxiliary Circuit 10 mm Control Circuit 10 mm Main Circuit 17 mm |
Degree of Protection: | acc. to IEC 60529, IEC 60947-1, EN 60529 Auxiliary Terminals IP20 acc. to IEC 60529, IEC 60947-1, EN 60529 Coil Terminals IP20 acc. to IEC 60529, IEC 60947-1, EN 60529 Main Terminals IP10 |
Recommended Screw Driver: | Pozidriv PZ |
Tightening Torque: | Auxiliary Circuit 1.2 N·m Control Circuit 1.2 N·m Main Circuit 6 N·m |
Terminal Type: | Screw Terminals |
Product Name: | Block Contactor |
Technical UL/CSA | |
Maximum Operating Voltage UL/CSA: | Main Circuit 600 V |
General Use Rating UL/CSA: | (600 V AC) 115 A |
Horsepower Rating UL/CSA: | (120 V AC) Single Phase 7-1/2 hp (200 … 208 V AC) Three Phase 30 hp (220 … 240 V AC) Three Phase 40 hp (240 V AC) Single Phase 20 hp (440 … 480 V AC) Three Phase 75 hp (550 … 600 V AC) Three Phase 75 hp |
Connecting Capacity Main Circuit UL/CSA: | Rigid Stranded 1/2x 6-1 AWG |
Tightening Torque UL/CSA: | Auxiliary Circuit 11 in·lb Control Circuit 11 in·lb Main Circuit 53 in·lb |
Full Load Amps Motor Use: | (120 V AC) Single Phase 80 A (200 … 208 V AC) Three Phase 92 A (220 … 240 V AC) Three Phase 80 A (240 V AC) Single Phase 88 A (440 … 480 V AC) Three Phase 77 A (550 … 600 V AC) Three Phase 77 A |
Environmental | |
Ambient Air Temperature: | Close to Contactor Fitted with Thermal O/L Relay -40 … 70 °C Close to Contactor without Thermal O/L Relay -40 … 70 °C Close to Contactor for Storage -60 … +80 °C |
Climatic Withstand: | Category B according to IEC 60947-1 Annex Q |
Maximum Operating Altitude Permissible: | Without Derating 3000 m |
Resistance to Shock acc. to IEC 60068-2-27: | Closed, Shock Direction: A 25 g Closed, Shock Direction: B1 25 g Closed, Shock Direction: B2 15 g Closed, Shock Direction: C1 25 g Closed, Shock Direction: C2 25 g Open, Shock Direction: B1 5 g |
Resistance to Vibrations: | 3g Closed Position & 3g Open Position 5 … 300 Hz |
Pollution Degree: | 3 |
Material Compliance | |
Conflict Minerals Reporting Template (CMRT): | CMRT – Conflict Minerals Reporting Template |
REACH Declaration: | REACH – Letter of Confirmation for block contactors, contactor relays, installation contactors, mini contactors, mini contactor relays, thermal overload relays, electronic overload relays and related accessories |
RoHS Information: | RoHS II declaration for block contactors, installation contactors, mini contactors, mini contactor relays, thermal overload relays, electronic overload relays and related accessories |
RoHS Status: | Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019 |
Toxic Substances Control Act – TSCA: | Toxic Substances Control Act (TSCA) declaration for Contactors |
WEEE B2C / B2B: | Business To Business |
WEEE Category: | 5. Small Equipment (No External Dimension More Than 50 cm) |
ABB EcoSolutions | |
ABB EcoSolutions: | Yes |
End Of Life Disassembling Instructions: | End of life instruction AF(S)40/52/65/80/96(B)(RT) Contactors |
Environmental Product Declaration – EPD: | Environmental Product Declaration AF80, AF96 (CN) Contactors Environmental Product Declaration AF(S)80(B), AF(S)96(B) (FR) |
Sustainable Material Content in Packaging (wt. %): | FSC Recycled Paper – 94.6 % |
Sustainable Material Content in Product (wt. %): | Recycled Metal – 28.2 % |
Certificates and Declarations | |
A2L Certificate – UL: | 9AKK108469A4890;9AKK108469A4892 |
ABS Certificate: | ABS Certificate, AF(S)09 to AF(S)96 contactors, NF contactor relays and CA4, CC4, CAL4, CAT4 auxiliary contact blocks, TEF4 electronic timers |
BV Certificate: | BV_2634H36994B1 |
CB Certificate: | CB Certificate AF(S)80(B), AF(S)96(B) 3 and 4-pole contactors |
CCC Certificate: | CQC Certificate, AC Contactor, AF(S):80-30-::-::, AF80-40-::-::, AF80-22-::-::, AF(S)96-30-::-::, Made in France |
Declaration of Conformity – CCC: | CCC Declaration of Conformity, AC Contactor, AF:80-30-::-::, AF80-40-::-::, AF80-22-::-::, AF:96-30-::-::, Made in France |
Declaration of Conformity – CE: | EU Declaration of Conformity AF09… AF96-30-.., AF09…38(Z)-30..K 3-pole Contactors |
Declaration of Conformity – UKCA: | UK Declaration of Conformity AF09… AF96-30-.., AF09…38(Z)-30..K 3-pole Contactors |
DNV Certificate: | DNV Certificate AF(S)09…96 3-pole & AF09…80 4-pole contactors with screw, spring, push-in terminals |
KC Certificate: | KC Certificate AF80, AF96 3-pole Contactors |
LR Certificate: | LRS Certificate AF(S)09..(K) … AF96 3 and 4-pole contactors and CA(L)4..(K), CAT4, CC4 auxiliary contact blocks |
RINA Certificate: | Rina Certificate for AF09…AF96 contactors, NF contactor relays and accessories, screw and spring terminals |
RMRS Certificate: | RMRS Certificate AF(S)09(S)…AF(S)38 3-pole and 4-pole, AF(S)40..96 3-pole contactors with screw, push-in and spring terminals |
UL Certificate: | UL-US-L312527-1141-10303102-9 UL-CA-L312527-4141-10303102-9 |
UL Listing Card: | UL_E312527 |
Container Information | |
Package Level 1 Units: | box 1 piece |
Package Level 1 Width: | 150 mm |
Package Level 1 Depth / Length: | 150 mm |
Package Level 1 Height: | 103 mm |
Package Level 1 Gross Weight: | 1.38 kg |
Package Level 1 EAN: | 3471523133310 |
Package Level 2 Units: | box 8 piece |
Package Level 2 Width: | 250 mm |
Package Level 2 Depth / Length: | 300 mm |
Package Level 2 Height: | 300 mm |
Package Level 2 Gross Weight: | 11.04 kg |
Package Level 3 Units: | 192 piece |
External Classifications and Standards | |
Object Classification Code: | Q |
ETIM 7: | EC000066 – Power contactor, AC switching |
ETIM 8: | EC000066 – Power contactor, AC switching |
ETIM 9: | EC000066 – Power contactor, AC switching |
eClass: | V11.0 : 27371003 |
UNSPSC: | 39121529 |
IDEA Granular Category Code (IGCC): | 4758 >> Iec Contactors |
E-Number (Finland): | 3707140 |