ABB UA110-30-00RA 110V 50Hz / 110-120V 60Hz

General Information

Extended Product Type: UA110-30-00RA-84
Product ID: 1SFL451024R8400
EAN: 7320500260555
Catalog Description: UA110-30-00RA 110V 50Hz Contactor
Long Description: A 3-phase Contactor suitable for Capacitor switching application. Maximum permissible peak current 100 times the nominal RMS current. Operated with a control voltage, versions from 24…….690 V
SKU: b780e4159193 Categories: ,

Description

Ordering
Minimum Order Quantity: 1 piece
Customs Tariff Number: 85364900
Popular Downloads
Data Sheet, Technical Information: 1SBC100214C0202 – Main catalog Motor protection and control Manual motor starters, contactors and overload relays (PDF) – Edition 2024
Instructions and Manuals: Contactors A95, A110, UA95, UA110, AF95, AF110, AE95, AE110, TAE95, TAE110
CAD Dimensional Drawing: Information – 2D and 3D files for CAD systems
Dimensions
Product Net Width: 90 mm
Product Net Depth / Length: 155.6 mm
Product Net Height: 170 mm
Product Net Weight: 1.8 kg
Technical
Number of Main Contacts NO: 3
Number of Main Contacts NC: 0
Number of Auxiliary Contacts NO: 0
Number of Auxiliary Contacts NC: 0
Number of Poles: 3P
Rated Operational Voltage: Main Circuit 1000 V
Rated Frequency (f): Main Circuit 50 Hz
Conventional Free-air Thermal Current (Ith): acc. to IEC 60947-4-1, Open Contactors Θ = 40 °C 160 A
Rated Operational Current AC-1 (Ie): (690 V) 40 °C 160 A
(690 V) 55 °C 145 A
(690 V) 60 °C 145 A
(690 V) 70 °C 130 A
Rated Operational Current AC-3 (Ie): (415 V) 55 °C 110 A
(440 V) 55 °C 100 A
(500 V) 55 °C 100 A
(690 V) 55 °C 82 A
(1000 V) 55 °C 30 A
(380 / 400 V) 55 °C 110 A
(220 / 230 / 240 V) 55 °C 110 A
Rated Operational Power AC-6b (Pe): (230 / 240 V) 40 °C, 50 / 60 Hz 45 kvar
(230 / 240 V) 55 °C, 50 / 60 Hz 40 kvar
(230 / 240 V) 70 °C, 50 / 60 Hz 35 kvar
(400 / 415 V) 40 °C, 50 / 60 Hz 80 kvar
(400 / 415 V) 70 °C, 50 / 60 Hz 60 kvar
(400 / 415 V) 55 °C, 50 / 60 Hz 70 kvar
(440 V) 40 °C, 50 / 60 Hz 85 kvar
(440 V) 55 °C, 50 / 60 Hz 75 kvar
(440 V) 70 °C, 50 / 60 Hz 70 kvar
(500 / 550 V), 40 °C, 50 / 60 Hz 95 kvar
(500 / 550 V) 55 °C, 50 / 60 Hz 82 kvar
(500 / 550 V) 70 °C, 50 / 60 Hz 78 kvar
(690 V) 40 °C, 50 / 60 Hz 130 kvar
(690 V) 55 °C, 50 / 60 Hz 110 kvar
(690 V) 70 °C, 50 / 60 Hz 100 kvar
Rated Breaking Capacity AC-3: 8 x Ie AC-3
Rated Making Capacity AC-3: 10 x Ie AC-3
Maximum Breaking Capacity: cos phi=0.45 (cos phi=0.35 for Ie > 100 A) at 440 V 1160 A
cos phi=0.45 (cos phi=0.35 for Ie > 100 A) at 690 V 800 A
Rated Insulation Voltage (Ui): acc. to IEC 60947-4-1 and VDE 0110 (Gr. C) 1000 V
acc. to UL/CSA 600 V
Rated Impulse Withstand Voltage (Uimp): Main Circuit 8 kV
Maximum Electrical Switching Frequency: (AC-1) 300 cycles per hour
(AC-2 / AC-4) 150 cycles per hour
(AC-3) 300 cycles per hour
Mechanical Durability: 10 million
Maximum Mechanical Switching Frequency: 3600 cycles per hour
Coil Operating Limits: (acc. to IEC 60947-4-1) 0.85 x Uc Min. … 1.1 x Uc Max. (at θ ≤ 70 °C)
Rated Control Circuit Voltage (Uc): 50 Hz 110 V
60 Hz 110 … 120 V
Coil Consumption: Holding at Max. Rated Control Circuit Voltage 50 Hz 22 V·A
Holding at Max. Rated Control Circuit Voltage 60 Hz 26 V·A
Pull-in at Max. Rated Control Circuit Voltage 50 Hz 350 V·A
Pull-in at Max. Rated Control Circuit Voltage 60 Hz 450 V·A
Power Loss: at Rated Operating Conditions per Pole 7.5 W
Operate Time: Between Coil De-energization and NC Contact Closing 7 … 15 ms
Between Coil Energization and NO Contact Closing 10 … 25 ms
Connecting Capacity Main Circuit: Bar 30 mm²
Flexible with Cable End 2 x 6 … 35 mm²
Rigid 1 x 10 … 95 mm²
Connecting Capacity Auxiliary Circuit: Flexible with Ferrule 1x 0.75 … 2.5 mm²
Flexible with Insulated Ferrule 2x 0.75 … 2.5 mm²
Flexible 2×0.75 … 2.5 mm²
Solid 2 x 1 … 4 mm²
Stranded 2 x 1 …. 4 mm²
Connecting Capacity: Bar 30 mm²
Flexible with Cable End 1 x 10 … 70 mm²
Rigid 1 x 10 … 95 mm²
Degree of Protection: acc. to IEC 60529, IEC 60947-1, EN 60529 Coil Terminals IP20
acc. to IEC 60529, IEC 60947-1, EN 60529 Main Terminals IP10
Connecting Terminals (delivered in open position) Main Poles: M8 hexagon socket screw with single connector
Tightening Torque: Main Circuit 8 N·m
Terminal Type: Cable Clamp
Product Name: Block Contactor
Technical UL/CSA
Maximum Operating Voltage UL/CSA: Main Circuit 600 V
Environmental
Ambient Air Temperature: Close to Contactor Fitted with Thermal O/L Relay (0.85 … 1.1 Uc) -25 … 50 °C
Close to Contactor without Thermal O/L Relay (0.85 … 1.1 Uc) -40 … 70 °C
Close to Contactor for Storage -60 … +80 °C
Maximum Operating Altitude Permissible: Without Derating 3000 m
Resistance to Shock acc. to IEC 60068-2-27: Half-sine Pulse for 11 ms, No Change in Contact Position, Open, Shock Direction: A 20 g
Half-sine Pulse for 11 ms, No Change in Contact Position, Closed, Shock Direction: A 20 g
Half-sine Pulse for 11 ms, No Change in Contact Position, Closed, Shock Direction: B1 15 g
Half-sine Pulse for 11 ms, No Change in Contact Position, Closed, Shock Direction: C1 20 g
Half-sine Pulse for 11 ms, No Change in Contact Position, Closed, Shock Direction: C2 20 g
Half-sine Pulse for 11 ms, No Change in Contact Position, Open, Shock Direction: B1 5 g
Half-sine Pulse for 11 ms, No Change in Contact Position, Open, Shock Direction: B2 15 g
Half-sine Pulse for 11 ms, No Change in Contact Position, Open, Shock Direction: C1 20 g
Half-sine Pulse for 11 ms, No Change in Contact Position, Open, Shock Direction: C2 20 g
Material Compliance
Conflict Minerals Reporting Template (CMRT): CMRT – Conflict Minerals Reporting Template
REACH Declaration: REACH – Letter of Confirmation for block contactors, contactor relays, installation contactors, mini contactors, mini contactor relays, thermal overload relays, electronic overload relays and related accessories
RoHS Information: RoHS II declaration for block contactors, installation contactors, mini contactors, mini contactor relays, thermal overload relays, electronic overload relays and related accessories
RoHS Status: Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019
Toxic Substances Control Act – TSCA: Toxic Substances Control Act (TSCA) declaration for Contactors
WEEE B2C / B2B: Business To Business
WEEE Category: 5. Small Equipment (No External Dimension More Than 50 cm)
Certificates and Declarations
CB Certificate: CB Certificate UA95(RA),UA110(RA) contactors
cULus Certificate: cULus Certificate, Contactor, A95…A110, AX95…AX150
Declaration of Conformity – CE: CE Declaration of Conformity – Contactor – A(F)95…A(F)300, AM110…AM300, UA95…UA110, (T)AE95….(T)AE110
Declaration of Conformity – UKCA: UK Declaration of Conformity – Contactors >100A
Container Information
Package Level 1 Units: box 1 piece
Package Level 1 Width: 170 mm
Package Level 1 Depth / Length: 140 mm
Package Level 1 Height: 170 mm
Package Level 1 Gross Weight: 2 kg
Package Level 1 EAN: 7320500260555
External Classifications and Standards
Object Classification Code: Q
ETIM 7: EC001079 – Capacitor contactor
ETIM 8: EC001079 – Capacitor contactor
ETIM 9: EC001079 – Capacitor contactor
eClass: V11.0 : 27371006
UNSPSC: 39121529
IDEA Granular Category Code (IGCC): 4756 >> Capacitor magnet contactor

Downloads