Description
Ordering | |
Minimum Order Quantity: | 1 piece |
Customs Tariff Number: | 85365080 |
Popular Downloads | |
Data Sheet, Technical Information: | 1SBC100214C0202 |
Instructions and Manuals: | 2CDC102047M6801 |
CAD Dimensional Drawing: | 2CDC001079B0201 |
Dimension Diagram: | GJL1200436F0001 |
Dimensions | |
Product Net Width: | 52.5 mm |
Product Net Height: | 57.5 mm |
Product Net Depth / Length: | 46.7 mm |
Product Net Weight: | 0.175 kg |
Technical | |
Number of Poles: | 3 |
Mini Contactor Type: | Mini Contactor |
Rated Operational Voltage: | Auxiliary Circuit 690 V AC Auxiliary Circuit 250 V DC Main Circuit 690 V AC Main Circuit 220 V DC |
Rated Frequency (f): | Control Circuit 400 Hz Control Circuit 50 Hz Control Circuit 60 Hz Main Circuit 60 Hz Main Circuit 50 Hz Main Circuit DC |
Rated Impulse Withstand Voltage (Uimp): | Auxiliary Circuit 6 kV Main Circuit 6 kV |
Rated Insulation Voltage (Ui): | 690 V acc. to UL/CSA 600 V |
Number of Main Contacts NC: | 0 |
Number of Main Contacts NO: | 3 |
Rated Operational Current AC-1 (Ie): | (220 / 240 V) 40 °C 20 A (220 / 240 V) 55 °C 16 A (380 / 440 V) 40 °C 20 A (380 / 440 V) 55 °C 16 A (690 V) 40 °C 6 A (690 V) 55 °C 6 A |
Rated Operational Power AC-3 (Pe): | (230 V) Three Phase 3 kW (400 V) Three Phase 5.5 kW (500 V) Three Phase 5.5 kW (690 V) Three Phase, NO 3 kW |
Rated Short-time Withstand Current Low Voltage (Icw): | at 40 °C Ambient Temp, in Free Air, from a Cold State 10 s 96 A |
Number of Auxiliary Contacts NC: | 1 |
Number of Auxiliary Contacts NO: | 0 |
Rated Operational Current AC-15 (Ie): | (24 V) 4 A (120 V) 4 A (500 V) 2 A (220 / 240 V) 4 A (380 / 400 V) 3 A |
Rated Operational Current DC-13 (Ie): | (24 V) 2.5 A (110 V) 0.7 A (220 / 240 V) 0.4 A |
Conventional Free-air Thermal Current (Ith): | Main Circuit 20 A |
Rated Control Circuit Voltage (Uc): | 380 … 415 V AC |
Coil Operating Limits: | (acc. to IEC 60947-4-1) for AC supply 0.85 … 1.1 x Uc (at θ ‰¤ 55 °C) |
Degree of Protection: | Auxiliary Circuit Terminals IP20 Control Circuit Terminals IP20 Main Circuit Terminals IP20 |
Mechanical Durability: | 10000000 cycle |
Minimum Switching Capacity: | Auxiliary Circuit 17 V Auxiliary Circuit 5 mA |
Maximum Electrical Switching Frequency: | (AC-1) 300 cycles per hour (AC-15) 600 cycles per hour (AC-3) 600 cycles per hour (DC-1) 600 cycles per hour (DC-13) 600 cycles per hour (DC-3) 600 cycles per hour |
Connecting Capacity Main Circuit: | Flexible with Ferrule 1/2x 1 … 2.5 mm² Flexible with Insulated Ferrule 1/2x 1 … 2.5 mm² Flexible 1/2x 1 … 2.5 mm² Rigid 1/2x 1 … 4 mm² |
Connecting Capacity Auxiliary Circuit: | Flexible with Ferrule 1/2x 1 … 2.5 mm² Flexible with Insulated Ferrule 1/2x 1 … 2.5 mm² Flexible 1/2x 1 … 2.5 mm² Rigid 1/2x 1 … 4 mm² |
Connecting Capacity Control Circuit: | Flexible with Ferrule 1/2x 1 … 2.5 mm² Flexible with Insulated Ferrule 1/2x 1 … 2.5 mm² Flexible 1/2x 1 … 2.5 mm² Rigid 1/2x 1 … 4 mm² |
Wire Stripping Length: | Auxiliary Circuit 9 mm Main Circuit 9 mm |
Tightening Torque: | Auxiliary Circuit 0.8 … 1.1 N·m Control Circuit 0.8 … 1.1 N·m Main Circuit 0.8 … 1.1 N·m |
Recommended Screw Driver: | M3 Pozidriv 1 |
Mounting on DIN Rail: | TH35-15 (35 x 15 mm Mounting Rail) acc. to IEC 60715 TH35-7.5 (35 x 7.5 mm Mounting Rail) acc. to IEC 60715 |
Power Loss: | at Rated Operating Conditions AC-1 per Pole 1.4 W |
Standards: | IEC/EN 60947-1 IEC/EN 60947-4-1 IEC/EN 60947-5-1 UL 60947-1 UL 60947-4-1 IEC 60335-2-40 A2L |
Technical UL/CSA | |
Maximum Operating Voltage UL/CSA: | Main Circuit 600 V AC |
Full Load Amps Motor Use: | (115 V AC) Single Phase 13.8 A (200 V AC) Three Phase 7.8 A (220 … 240 V AC) Three Phase 9.6 A (230 V AC) Single Phase 10 A (440 … 480 V AC) Three Phase 7.6 A (550 … 600 V AC) Three Phase 6.1 A |
Horsepower Rating UL/CSA: | (115 V AC) Single Phase 0.75 Hp (200 V AC) Three Phase 2 Hp (220 … 240 V AC) Three Phase 3 Hp (230 V AC) Single Phase 1.5 Hp (440 … 480 V AC) Three Phase 5 Hp (550 … 600 V AC) Three Phase 5 Hp |
General Use Rating UL/CSA: | (600 V AC) 16 A |
Contact Rating UL/CSA: | A600 |
Connecting Capacity Main Circuit UL/CSA: | Stranded 1/2x 22-10 AWG |
Connecting Capacity Auxiliary Circuit UL/CSA: | Stranded 1/2x 22-10 AWG |
Tightening Torque UL/CSA: | Auxiliary Circuit 7 in·lb Control Circuit 7 in·lb Main Circuit 7 in·lb |
Environmental | |
Ambient Air Temperature: | Operation -25 … +55 °C Storage -40 … +80 °C |
Maximum Operating Altitude Permissible: | 2000 m |
Resistance to Shock acc. to IEC 60068-2-27: | 11 ms Pulse 15g |
Resistance to Vibrations: | 5g 5 … 150 Hz |
Material Compliance | |
Conflict Minerals Reporting Template (CMRT): | 9AKK108467A5658 |
REACH Declaration: | 2CMT2021-006202 |
RoHS Information: | 2CMT2021-006277 |
RoHS Status: | Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019 |
Toxic Substances Control Act – TSCA: | 2CMT2023-006525 |
WEEE B2C / B2B: | Business To Business |
WEEE Category: | 5. Small Equipment (No External Dimension More Than 50 cm) |
Certificates and Declarations | |
A2L Certificate €“ IEC: | 1SAA938000-4601 |
BV Certificate: | 1SAA920000-0204 |
CB Certificate: | 1SAA938000-2002 |
CQC Certificate: | CQC2003010304064033 |
Declaration of Conformity – CCC: | 2020980304001854 |
Declaration of Conformity – CE: | 1SAD101100-3101 |
Declaration of Conformity – UKCA: | 1SAD201100-3101 |
DNV GL Certificate: | 1SAA938000-0306 |
EAC Certificate: | 1SAA920000-2702 |
KC Certificate: | 1SAA938000-1501 |
LR Certificate: | 1SAA938000-0504 |
RMRS Certificate: | 1SAA938000-0704 |
UL Certificate: | E191658-19881208 |
Container Information | |
Package Level 1 Units: | box 10 piece |
Package Level 1 Width: | 115 mm |
Package Level 1 Height: | 54 mm |
Package Level 1 Depth / Length: | 280 mm |
Package Level 1 Gross Weight: | 1.82 kg |
Package Level 1 EAN: | 4013614416620 |
Classifications | |
Object Classification Code: | Q |
ETIM 4: | EC000066 – Magnet contactor, AC-switching |
ETIM 5: | EC000066 – Magnet contactor, AC-switching |
ETIM 6: | EC000066 – Power contactor, AC switching |
ETIM 7: | EC000066 – Power contactor, AC switching |
ETIM 8: | EC000066 – Power contactor, AC switching |
eClass: | V11.0 : 27371003 |
UNSPSC: | 39121529 |
E-Number (Sweden): | 3210687 |
IDEA Granular Category Code (IGCC): | 4761 >> Magnet contactor, AC-switching |