ABB BC6-30-01-F-2.4-51 Mini Contactor 17 … 32 V DC – 3 NO – 0 NC – Flat-Pin Connections

General Information

Extended Product Type: BC6-30-01-F-2.4-51
Product ID: GJL1213003R5011
EAN: 4013614053221
Catalog Description: BC6-30-01-F-2.4-51 Mini Contactor 17 … 32 V DC – 3 NO – 0 NC – Flat-Pin Connections
Long Description: The BC6-30-01-F mini contactor is a compact 3 pole contactor with 1 auxiliary contact and flat pin connector. They are ideally suited for applications where reliability is a must and space is at a premium. Mini contactors are used in residential buldings, commercial buildings and industrial applications for the control of single or three-phase loads up to 4 kW (AC-3) and 20 A (AC-1) or switching of control signals. Due to the low coil consumption, this device can be directly controlled by a PLC. Further features are the noiseless and hum-free coil, a switch position indication and the integrated possibility for rail or wall mounting.
SKU: 8164f6f7a3ec Categories: ,

Description

Ordering
Minimum Order Quantity: 1 piece
Customs Tariff Number: 85365080
Popular Downloads
Data Sheet, Technical Information: 1SBC100214C0202
Instructions and Manuals: 2CDC102047M6801
CAD Dimensional Drawing: 2CDC001079B0201
Dimension Diagram: GJL1200437F0001
Dimensions
Product Net Width: 52.5 mm
Product Net Height: 57.5 mm
Product Net Depth / Length: 46.7 mm
Product Net Weight: 0.17 kg
Technical
Number of Poles: 3
Mini Contactor Type: Interface Mini Contactor
Rated Operational Voltage: Auxiliary Circuit 690 V AC
Auxiliary Circuit 250 V DC
Main Circuit 690 V AC
Main Circuit 220 V DC
Rated Frequency (f): Control Circuit DC
Main Circuit 60 Hz
Main Circuit 50 Hz
Main Circuit DC
Rated Impulse Withstand Voltage (Uimp): Auxiliary Circuit 6 kV
Main Circuit 6 kV
Rated Insulation Voltage (Ui): 690 V
acc. to UL/CSA 600 V
Number of Main Contacts NC: 0
Number of Main Contacts NO: 3
Rated Operational Current AC-1 (Ie): (220 / 240 V) 40 °C 20 A
(220 / 240 V) 55 °C 16 A
(380 / 440 V) 40 °C 20 A
(380 / 440 V) 55 °C 16 A
(690 V) 40 °C 6 A
(690 V) 55 °C 6 A
Rated Operational Power AC-3 (Pe): (230 V) Three Phase 2.2 kW
(400 V) Three Phase 4 kW
(500 V) Three Phase 4 kW
(690 V) Three Phase, NO 3 kW
Rated Short-time Withstand Current Low Voltage (Icw): at 40 °C Ambient Temp, in Free Air, from a Cold State 10 s 64 A
Number of Auxiliary Contacts NC: 1
Number of Auxiliary Contacts NO: 0
Rated Operational Current AC-15 (Ie): (24 V) 4 A
(120 V) 4 A
(500 V) 2 A
(220 / 240 V) 4 A
(380 / 400 V) 3 A
Rated Operational Current DC-13 (Ie): (24 V) 2.5 A
(110 V) 0.7 A
(220 / 240 V) 0.4 A
Conventional Free-air Thermal Current (Ith): Main Circuit 20 A
Rated Control Circuit Voltage (Uc): 17 … 32 V DC
Coil Operating Limits: (acc. to IEC 60947-4-1) for DC supply Uc Min. … Uc Max. (at θ ‰¤ 55 °C)
Degree of Protection: Auxiliary Circuit Terminals IP20
Control Circuit Terminals IP20
Main Circuit Terminals IP20
Mechanical Durability: 10000000 cycle
Minimum Switching Capacity: Auxiliary Circuit 17 V
Auxiliary Circuit 5 mA
Maximum Electrical Switching Frequency: (AC-1) 300 cycles per hour
(AC-15) 600 cycles per hour
(AC-3) 600 cycles per hour
(DC-1) 600 cycles per hour
(DC-13) 600 cycles per hour
(DC-3) 600 cycles per hour
Mounting on DIN Rail: TH35-15 (35 x 15 mm Mounting Rail) acc. to IEC 60715
TH35-7.5 (35 x 7.5 mm Mounting Rail) acc. to IEC 60715
Power Loss: at Rated Operating Conditions AC-1 per Pole 1 W
Standards: IEC/EN 60947-1
IEC/EN 60947-4-1
IEC/EN 60947-5-1
UL 60947-1
UL 60947-4-1
IEC 60335-2-40 A2L
Remarks: No CA6 or CAF6 mountable
Technical UL/CSA
Maximum Operating Voltage UL/CSA: Main Circuit 600 V AC
Full Load Amps Motor Use: (115 V AC) Single Phase 5.8 A
(200 V AC) Three Phase 4.8 A
(220 … 240 V AC) Three Phase 6.8 A
(230 V AC) Single Phase 4.9 A
(440 … 480 V AC) Three Phase 4.8 A
(550 … 600 V AC) Three Phase 1.7 A
Horsepower Rating UL/CSA: (115 V AC) Single Phase 0.25 Hp
(200 V AC) Three Phase 1 Hp
(220 … 240 V AC) Three Phase 2 Hp
(230 V AC) Single Phase 0.5 Hp
(440 … 480 V AC) Three Phase 3 Hp
(550 … 600 V AC) Three Phase 1 Hp
General Use Rating UL/CSA: (300 V AC) 12 A
Contact Rating UL/CSA: A600
Environmental
Ambient Air Temperature: Operation -20 … +55 °C
Storage -40 … +80 °C
Maximum Operating Altitude Permissible: 2000 m
Resistance to Shock acc. to IEC 60068-2-27: 11 ms Pulse 15g
Resistance to Vibrations: 5g 5 … 150 Hz
Material Compliance
Conflict Minerals Reporting Template (CMRT): 9AKK108467A5658
REACH Declaration: 2CMT2021-006202
RoHS Information: 2CMT2021-006277
RoHS Status: Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019
Toxic Substances Control Act – TSCA: 2CMT2023-006525
WEEE B2C / B2B: Business To Business
WEEE Category: 5. Small Equipment (No External Dimension More Than 50 cm)
Certificates and Declarations
A2L Certificate €“ IEC: 1SAA938000-4601
BV Certificate: 1SAA920000-0204
CB Certificate: 1SAA938000-2002
CQC Certificate: CQC2003010304064033
cURus Certificate: cUL_E191658
Declaration of Conformity – CCC: 2020980304001854
Declaration of Conformity – CE: 1SAD101100-3101
Declaration of Conformity – UKCA: 1SAD201100-3101
DNV GL Certificate: 1SAA938000-0306
EAC Certificate: 1SAA920000-2702
KC Certificate: 1SAA938000-1501
LR Certificate: 1SAA938000-0504
RMRS Certificate: 1SAA938000-0704
Container Information
Package Level 1 Units: box 10 piece
Package Level 1 Width: 115 mm
Package Level 1 Height: 54 mm
Package Level 1 Depth / Length: 280 mm
Package Level 1 Gross Weight: 1.77 kg
Package Level 1 EAN: 4013614414961
Classifications
Object Classification Code: Q
ETIM 4: EC000066 – Magnet contactor, AC-switching
ETIM 5: EC000066 – Magnet contactor, AC-switching
ETIM 6: EC000066 – Power contactor, AC switching
ETIM 7: EC000066 – Power contactor, AC switching
ETIM 8: EC000066 – Power contactor, AC switching
eClass: V11.0 : 27371003
UNSPSC: 39121529

Downloads

Certificate Datasheet