| Dimensions |
| Ürün Net Genişliği: |
96.2 mm |
| Ürün Net Yüksekliği: |
57.5 mm |
| Ürün Net Derinlik / Uzunluk: |
46.7 mm |
| Ürün Net Ağırlığı: |
0.355 kg |
| Technical |
| Kutup Sayısı: |
3P |
| Nominal Çalışma Gerilimi: |
Auxiliary Circuit 690 V AC | Auxiliary Circuit 250 V DC | Main Circuit 690 V AC | Main Circuit 220 V DC |
| Nominal Frekans (f): |
Control Circuit 400 Hz | Control Circuit 50 Hz | Control Circuit 60 Hz | Main Circuit 60 Hz | Main Circuit 50 Hz | Main Circuit DC |
| Rated Impulse Withstand Voltage (Uimp): |
Main Circuit 6 kV |
| Rated Insulation Voltage (Ui): |
690 V | acc. to UL/CSA 600 V |
| Number of Main Contacts NC: |
0 |
| Number of Main Contacts NO: |
3 |
| Rated Operational Current AC-1 (Ie): |
(220 / 240 V) 40 °C 20 A | (220 / 240 V) 55 °C 16 A | (380 / 440 V) 40 °C 20 A | (380 / 440 V) 55 °C 16 A | (690 V) 40 °C 6 A | (690 V) 55 °C 6 A |
| Rated Operational Power AC-3 (Pe): |
(230 V) Three Phase 2.2 kW | (400 V) Three Phase 4 kW | (500 V) Three Phase 4 kW | (690 V) Three Phase, NO 3 kW |
| Rated Short-time Withstand Current Low Voltage (Icw): |
at 40 °C Ambient Temp, in Free Air, from a Cold State 10 s 64 A |
| Number of Auxiliary Contacts NC: |
1 |
| Number of Auxiliary Contacts NO: |
0 |
| Rated Operational Current AC-15 (Ie): |
(440 V AC) 3 A | (24 V) 4 A | (120 V) 4 A | (240 V) 4 A | (500 V) 2 A | (380 / 400 V) 3 A |
| Rated Operational Current DC-13 (Ie): |
(24 V) 2.5 A | (110 V) 0.7 A | (220 / 240 V) 0.4 A |
| Conventional Free-air Thermal Current (Ith): |
Main Circuit 20 A |
| Rated Control Circuit Voltage (Uc): |
380 … 415 V AC |
| Coil Operating Limits: |
(acc. to IEC 60947-4-1) for AC supply 0.85 … 1.1 x Uc (at θ ≤ 55 °C) | (acc. to IEC 60947-4-1) for DC supply 0.85 … 1.1 x Uc (at θ ≤ 55 °C) |
| Koruma Derecesi: |
Auxiliary Circuit Terminals IP20 | Control Circuit Terminals IP20 | Main Circuit Terminals IP20 |
| Pollution Degree: |
3 |
| Mechanical Durability: |
10000000 cycle |
| Minimum Switching Capacity: |
Auxiliary Circuit 17 V | Auxiliary Circuit 5 mA |
| Maximum Electrical Switching Frequency: |
(AC-1) 300 cycles per hour | (AC-15) 600 cycles per hour | (AC-3) 600 cycles per hour | (DC-1) 600 cycles per hour | (DC-13) 600 cycles per hour | (DC-3) 600 cycles per hour |
| Connecting Capacity Main Circuit: |
Flexible with Ferrule 1/2x 1 … 2.5 mm² | Flexible with Insulated Ferrule 1/2x 1 … 2.5 mm² | Flexible 1/2x 1 … 2.5 mm² | Rigid 1/2x 1 … 4 mm² |
| Connecting Capacity Auxiliary Circuit: |
Flexible with Ferrule 1/2x 1 … 2.5 mm² | Flexible with Insulated Ferrule 1/2x 1 … 2.5 mm² | Flexible 1/2x 1 … 2.5 mm² | Rigid 1/2x 1 … 4 mm² |
| Connecting Capacity Control Circuit: |
Flexible with Ferrule 1/2x 1 … 2.5 mm² | Flexible with Insulated Ferrule 1/2x 1 … 2.5 mm² | Flexible 1/2x 1 … 2.5 mm² | Rigid 1/2x 1 … 4 mm² |
| Wire Stripping Length: |
Auxiliary Circuit 9 mm | Main Circuit 9 mm |
| Sıkma Torku: |
Control Circuit 0.8 … 1.1 N·m | Main Circuit 0.8 … 1.1 N·m |
| Recommended Screw Driver: |
M3 | Pozidriv 1 |
| DIN Rayına Montaj: |
TH35-15 (35 x 15 mm Mounting Rail) acc. to IEC 60715 | TH35-7.5 (35 x 7.5 mm Mounting Rail) acc. to IEC 60715 |
| Power Loss: |
at Rated Operating Conditions AC-1 per Pole 1 W |
| Standartlar: |
IEC/EN 60947-1 | IEC/EN 60947-4-1 | IEC/EN 60947-5-1 | UL 60947-1 | UL 60947-4-1 | IEC 60335-2-40 A2L |
| Technical UL/CSA |
| Maximum Operating Voltage UL/CSA: |
Main Circuit 600 V AC |
| Full Load Amps Motor Use: |
(115 V AC) Single Phase 5.8 A | (200 V AC) Three Phase 4.8 A | (220 … 240 V AC) Three Phase 6.8 A | (230 V AC) Single Phase 4.9 A | (440 … 480 V AC) Three Phase 4.8 A | (550 … 600 V AC) Three Phase 1.7 A |
| Beygir Gücü Anma UL/CSA: |
(115 V AC) Single Phase 0.25 Hp | (200 V AC) Three Phase 1 Hp | (220 … 240 V AC) Three Phase 2 Hp | (230 V AC) Single Phase 0.5 Hp | (440 … 480 V AC) Three Phase 3 Hp | (550 … 600 V AC) Three Phase 1 Hp |
| General Use Rating UL/CSA: |
(300 V AC) 12 A |
| Contact Rating UL/CSA: |
A600 |
| Connecting Capacity Main Circuit UL/CSA: |
Stranded 1/2x 22-10 AWG |
| Connecting Capacity Auxiliary Circuit UL/CSA: |
Stranded 1/2x 22-10 AWG |
| Tightening Torque UL/CSA: |
Auxiliary Circuit 7 in·lb | Control Circuit 7 in·lb | Main Circuit 7 in·lb |
| Environmental |
| Ortam Hava Sıcaklığı: |
Operation -20 … +55 °C | Storage -40 … +80 °C |
| İzin Verilen Maksimum Çalışma Rakımı: |
2000 m |
| IEC 60068-2-27’ye göre Şoka Karşı Direnç: |
11 ms Pulse 15g |
| Resistance to Vibrations: |
5g 5 … 150 Hz |
| Material Compliance |
| Conflict Minerals Reporting Template (CMRT): |
CMRT – Conflict Minerals Reporting Template |
| REACH Declaration: |
REACH – Letter of Confirmation for block contactors, contactor relays, installation contactors, mini contactors, mini contactor relays, thermal overload relays, electronic overload relays and related accessories |
| RoHS Bilgileri: |
RoHS II declaration for block contactors, installation contactors, mini contactors, mini contactor relays, thermal overload relays, electronic overload relays and related accessories |
| RoHS Durumu: |
Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019 |
| Toxic Substances Control Act – TSCA: |
Toxic Substances Control Act (TSCA) declaration for Contactors |
| AEEE B2C / B2B: |
Business To Business |
| AEEE Kategorisi: |
5. Small Equipment (No External Dimension More Than 50 cm) |
| ABB EcoSolutions |
| Environmental Product Declaration – EPD: |
Environmental Product Declaration PEP VB(C)7, VB(C)7 |
| Certificates and Declarations |
| A2L Certificate – IEC: |
A2L Certificate – B6-, B7-, K6- series, CA6, CAF6 – Mini Contactor |
| CB Certificate: |
CB Certificate – B6, BC6, VB6, VBC6, B7, BC7, VB7, VBC7 – Mini Contactor |
| CQC Certificate: |
CQC Certificate, AC Contactor, B6,BC6,B7,BC7,VB6,VBC6,VB7,VBC7, Made in Germany |
| Declaration of Conformity – CCC: |
CCC Declaration of Conformity, AC Contactor, B6,BC6,B7,BC7,VB6,VBC6,VB7,VBC7, Made in Germany |
| Uygunluk Beyanı – CE: |
EU Declaration of Conformity – B6, B7, K6, VB6, VB7, TBC7, TKC6 – Mini Contactor |
| Declaration of Conformity – UKCA: |
UK Declaration of Conformity – B6, B7, K6, VB6, VB7, TBC7, TKC6 – Mini Contactor |
| DNV GL Certificate: |
DNV Certificate – B6, B7 – Mini Contactor |
| EAC Certificate: |
EAC Certificate – B6, BC6, B6S, VB6,B7, BC7, B7D, B7S, VB7, TBC7, ESB24, EN24, ESB40, EN40, ESB63 – Contactors |
| KC Certificate: |
KC Certificate – B6, B7 |
| RMRS Sertifikası: |
RMRS Certificate – B6, BC6, B7, BC7, VB6, VBC6, VB7, VBC7 – Mini Contactor |
| UL Sertifikası: |
UL Certificate of Compliance – B6, B7 – Mini Contactor |
| Container Information |
| Paket Seviye 1 Birimler: |
box 5 piece |
| Paket Düzey 1 Genişlik: |
115 mm |
| Paket Seviye 1 Yükseklik: |
54 mm |
| Paket Seviye 1 Derinlik / Uzunluk: |
280 mm |
| Paket Seviye 1 Brüt Ağırlık: |
1.845 kg |
| Paket Düzey 1 EAN: |
4013614413773 |
| Classifications |
| Nesne Sınıflandırma Kodu: |
Q |
| ETIM 4: |
EC000066 – Magnet contactor, AC-switching |
| ETIM 5: |
EC000010 – Starter combination |
| ETIM 6: |
EC000010 – Combination of contactors |
| ETIM 7: |
EC000010 – Combination of contactors |
| ETIM 8: |
EC000010 – Combination of contactors |
| eSınıf: |
V11.0 : 27371009 |
| UNSPSC: |
39121529 |