Description
| ABB EcoSolutions | |
| ABB EcoSolutions: | Yes |
| Circular Value | |
| Circular Design Principles Recyclability Rate: | Design for Closing Resource Loops – Standard EN45555 – 55.9 % |
| End of Life Instructions: | 9AKK108468A2347 |
| Group Waste to Landfill Target: | UL 2799 Zero Waste To Landfill Validation available |
| Eco Transparency | |
| Environmental Product Declaration – EPD: | 9AKK108468A1890 9AKK108468A7793 |
| Environmental | |
| Environmental Information: | 9AKK108467A6707 |
| Material Compliance | |
| REACH Declaration: | 9AKK108466A1425 |
| RoHS Information: | 9AKK108466A1424 |
| RoHS Status: | Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019 |
| Conflict Minerals Reporting Template (CMRT): | 9AKK108467A5658 |
| Toxic Substances Control Act – TSCA: | 9AKK108467A8326 |
| SCIP: | 9965ca99-affa-4173-b6ec-86c5b94f7e15 Italy (IT) |
| Simplified SCIP: | 0baf7834-5c1e-4ab6-92f8-fe1c0c18d111 Germany (DE) 690bbaca-e914-49b1-b061-fadc8cb41754 Netherlands (NL) 1d9c93da-ce2a-496b-963a-5aa10a5952ea Netherlands (NL) faccd3ac-7bd6-452b-b339-f3e8650b7ed7 Germany (DE) 3971316a-abb7-4fb7-a3a4-b645aa241259 Denmark (DK) adf816cc-8afa-408f-b37f-84d38645b9ce Germany (DE) f57e9c1b-e394-43c6-92b6-24992fec4513 Croatia (HR) a23327a4-9935-4203-a9d5-741ba39df896 Czech Republic (CZ) b8b0676f-7b3e-4d5c-aa3c-7b6ebfe5bc3e Netherlands (NL) 678300f8-ecd0-4b74-8804-18f219da3ae0 Netherlands (NL) 2d166b04-bfde-406d-ae1b-a2d4f9a45c1f Estonia (EE) 769c0bf8-bb50-4b05-90d1-f148493e2e93 Greece (GR) c222885d-c4e3-48f8-aa94-67f29ec03c2e Portugal (PT) 0fa0c29c-f77e-4742-bd29-9f67a5dd58e7 Bulgaria (BG) 3a1ec757-f5bc-4fe2-a796-b80d5848b865 Sweden (SE) 3380a59b-f15a-4f8b-8fe2-54d228c70377 Poland (PL) 25e84eae-96f0-42ce-9d7d-9dfb5f5ce2a5 France (FR) dafbc307-d434-4abc-8c03-c64d3fc1c333 Sweden (SE) 3b414454-d89f-4090-bb59-470a3c7330ea Germany (DE) 59695450-664d-4372-9510-6f5c4ac5ad03 Germany (DE) 35ec2353-58cd-472a-b909-85aa064a6204 Spain (ES) 95a1642c-9a73-4d2e-8a1b-c20ad5fc8a6c Netherlands (NL) 5ec14cea-f544-4faa-ab16-fd3819a27732 Poland (PL) ca56bfe2-177d-4ed2-a416-d34db5ca5989 Poland (PL) 37ce67d3-3a1a-4ca0-b8ae-7bf5eec07bd9 Finland (FI) 3f937e08-97bb-4c73-ac98-fbbab57d1a84 Norway (NO) b394e0ce-ed58-41d4-9e52-9fc27c75e4e8 France (FR) |
| Ordering | |
| Order Code US and Canada: | XT1CE3100AFF000XXX |
| E-Number (Finland): | 3638777 |
| EAN: | 8015644012915 |
| Minimum Order Quantity: | 1 piece |
| Customs Tariff Number: | 85362090 |
| Dimensions | |
| Product Net Width: | 76.2 mm |
| Product Net Height: | 130 mm |
| Product Net Depth / Length: | 70 mm |
| Product Net Weight: | 1.1 kg |
| Container Information | |
| Package Level 1 Units: | box 1 piece |
| Package Level 1 Width: | 128 mm |
| Package Level 1 Height: | 135 mm |
| Package Level 1 Depth / Length: | 143 mm |
| Package Level 1 Gross Weight: | 1.136 kg |
| Package Level 1 EAN: | 8015644012915 |
| Additional Information | |
| Circuit Breaker Type to be Associated: | Power Distribution |
| Product Main Type: | SACE Tmax XT |
| Product Name: | Moulded Case Circuit Breaker |
| Product Type: | Automatic Circuit Breaker |
| Version: | F |
| CAD Dimensional Drawing: | 1SDH001295R0008 |
| Technical | |
| Connecting Capacity Main Circuit: | Busbar 45.5 … 80 mm² |
| Current Type: | AC/DC |
| Electrical Durability: | 120 cycles per hour 8000 cycle |
| Mechanical Durability: | 240 cycles per hour 25000 cycle |
| Number of Poles: | 3 |
| Opening Time: | CB with SOR 15 ms CB with UVR 15 ms |
| Order Multiple: | 1 piece |
| Power Loss: | at Rated Operating Conditions per Pole 7 W |
| Rated Current (In): | 100 A |
| Rated Frequency (f): | 50 / 60 Hz |
| Rated Impulse Withstand Voltage (Uimp): | 8 kV |
| Rated Instantaneous Short-Circuit Current Setting (Ii): | 1000 A |
| Rated Insulation Voltage (Ui): | 800 V |
| Rated Operational Voltage: | 690 V AC 500 V DC |
| Rated Service Short-Circuit Breaking Capacity (Ics): | (220 V AC) 40 kA (230 V AC) 40 kA (240 V AC) 40 kA (380 V AC) 25 kA (415 V AC) 25 kA (440 V AC) 12.5 kA (500 V AC) 9 kA (525 V AC) 8 kA (690 V AC) 4 kA (250 V DC) 2 Poles in Series 25 kA (500 V DC) 3 Poles in Series 25 kA |
| Rated Ultimate Short-Circuit Breaking Capacity (Icu): | (220 V AC) 40 kA (230 V AC) 40 kA (240 V AC) 40 kA (380 V AC) 25 kA (415 V AC) 25 kA (440 V AC) 25 kA (500 V AC) 18 kA (525 V AC) 8 kA (690 V AC) 4 kA (250 V DC) 2 Poles in Series 25 kA (500 V DC) 3 Poles in Series 25 kA |
| Rated Uninterrupted Current (Iu): | 160 A |
| Rated Voltage (Ur): | 690 V |
| Recommended Screw Driver: | Main Circuit M6 |
| Release: | TMD |
| Release Type: | TM |
| Setting Range: | 70…100 A |
| Short-Circuit Performance Level: | C |
| Standards: | IEC60947-2 |
| Sub-type: | XT1 |
| Terminal Connection Type: | Front |
| Terminal Type: | Bolt |
| Tightening Torque: | 6 N·m |
| Certificates and Declarations | |
| ATEX Certificate: | No certification needed |
| Data Sheet, Technical Information: | 1SDC210100D0206 1SDC210099D0206 |
| Declaration of Conformity – CE: | 9AKK106713A5532 |
| GL Certificate: | 1SDL000163R0103 |
| LR Certificate: | 1SDL000163R0100 |
| UL Certificate: | No certification needed |
| VDE Certificate: | No certification needed |
| Dimension Diagram: | 1SDH000719R0100 |
| Mechanical Drawings: | 1SDH000719R0100 |
| Wiring Diagram: | 1SDM000068R0001 |
| Instructions and Manuals: | 1SDH000719R0001 |
| Classifications | |
| ETIM 8: | EC000228 – Power circuit-breaker for trafo/generator/installation protection |
| ETIM 9: | EC000228 – Power circuit-breaker for trafo/generator/installation protection |
| Object Classification Code: | Q |
| UNSPSC: | 39120000 |
| WEEE Category: | 5. Small Equipment (No External Dimension More Than 50 cm) |
| eClass: | V11.1 : 27370409 |