Description
| ABB EcoSolutions | |
| ABB EcoSolutions: | Yes |
| Circular Value | |
| Circular Design Principles Recyclability Rate: | Design for Closing Resource Loops – Standard EN45555 – 55.9 % |
| End of Life Instructions: | 9AKK108468A2347 |
| Group Waste to Landfill Target: | UL 2799 Zero Waste To Landfill Validation available |
| Eco Transparency | |
| Environmental Product Declaration – EPD: | 9AKK108468A1890 9AKK108468A7793 |
| Environmental | |
| Environmental Information: | 9AKK108467A6707 |
| Material Compliance | |
| REACH Declaration: | 9AKK108466A1425 |
| RoHS Information: | 9AKK108466A1424 |
| RoHS Status: | Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019 |
| Conflict Minerals Reporting Template (CMRT): | 9AKK108467A5658 |
| Toxic Substances Control Act – TSCA: | 9AKK108467A8326 |
| SCIP: | 8a91ff6a-ad35-4fb5-a92a-df6404a582cb Italy (IT) |
| Simplified SCIP: | ff22bf26-0f34-41ea-99ef-86eed6814bc5 Germany (DE) 52ef1d57-7ac3-4b6f-a7e4-e82a028ffb83 Netherlands (NL) 74d485f3-103e-4d7a-8443-1f7ad4022261 Netherlands (NL) f4830c59-0293-41c0-b6c6-bbc224ef389e Germany (DE) 75045930-dcf8-4bdf-a8a6-b1d7536722b0 Denmark (DK) 00d5e05b-73de-4ffd-ada4-75fe59753d1b Germany (DE) a3bb56c5-c825-461f-b74a-af460f0a46b3 Croatia (HR) 511b521b-ee85-4c5d-bc0a-7a79e53ee659 Czech Republic (CZ) 6c056f27-91fa-4473-854f-037e49936562 Netherlands (NL) 4019c24c-8691-4202-9180-e5d03adce627 Netherlands (NL) 48db9e10-b526-4ac0-aae6-d10ceea229d1 Estonia (EE) ba95b5e4-99d5-4eea-b2c9-cb155dd74fa9 Greece (GR) c445fb07-7d15-41b6-a68d-cdb076abe0f1 Portugal (PT) 2bbe0591-3502-4ecc-b98b-6a391f7c3659 Bulgaria (BG) eb299f83-c903-4a3c-b98c-1d1fc6bbcadb Sweden (SE) 6abe2cd0-f062-4d83-9004-c331378e8e51 Poland (PL) e62cb378-2733-4350-aa9c-3b6ed41c578f France (FR) 30e1b010-9328-4a58-8902-080379a87c23 Sweden (SE) be0d0faf-5974-449f-b370-495cba09cb01 Germany (DE) 9140d5d7-7c67-405b-bf7e-5475de634beb Germany (DE) 23f70161-83b5-42b7-b046-4553eb6db904 Spain (ES) 7cce477e-45c8-445e-9a44-47829e0653e7 Netherlands (NL) d5142b24-b2c5-442e-92f1-34be6bf004b6 Poland (PL) 0da3aafb-d5a7-44a0-866d-3774ab59123e Poland (PL) 9d65d086-3f78-4165-b15a-c20f5c9a033b Finland (FI) 167b4a8a-f6f6-4ac1-b303-632a0bd3431b Norway (NO) 3b58e72f-8f59-4998-b549-8ee112e84c38 France (FR) |
| Ordering | |
| Order Code US and Canada: | XT1CE3040AFF000XXX |
| E-Number (Finland): | 3638775 |
| EAN: | 8015644012175 |
| Minimum Order Quantity: | 1 piece |
| Customs Tariff Number: | 85362090 |
| Dimensions | |
| Product Net Width: | 76.2 mm |
| Product Net Height: | 130 mm |
| Product Net Depth / Length: | 70 mm |
| Product Net Weight: | 1.1 kg |
| Container Information | |
| Package Level 1 Units: | box 1 piece |
| Package Level 1 Width: | 128 mm |
| Package Level 1 Height: | 135 mm |
| Package Level 1 Depth / Length: | 143 mm |
| Package Level 1 Gross Weight: | 1.12 kg |
| Package Level 1 EAN: | 8015644012175 |
| Additional Information | |
| Circuit Breaker Type to be Associated: | Power Distribution |
| Product Main Type: | SACE Tmax XT |
| Product Name: | Moulded Case Circuit Breaker |
| Product Type: | Automatic Circuit Breaker |
| Version: | F |
| CAD Dimensional Drawing: | 1SDH001295R0008 |
| Technical | |
| Connecting Capacity Main Circuit: | Busbar 45.5 … 80 mm² |
| Current Type: | AC/DC |
| Electrical Durability: | 120 cycles per hour 8000 cycle |
| Mechanical Durability: | 240 cycles per hour 25000 cycle |
| Number of Poles: | 3 |
| Opening Time: | CB with SOR 15 ms CB with UVR 15 ms |
| Order Multiple: | 1 piece |
| Power Loss: | at Rated Operating Conditions per Pole 2.6 W |
| Rated Current (In): | 40 A |
| Rated Frequency (f): | 50 / 60 Hz |
| Rated Impulse Withstand Voltage (Uimp): | 8 kV |
| Rated Instantaneous Short-Circuit Current Setting (Ii): | 450 A |
| Rated Insulation Voltage (Ui): | 800 V |
| Rated Operational Voltage: | 690 V AC 500 V DC |
| Rated Service Short-Circuit Breaking Capacity (Ics): | (220 V AC) 40 kA (230 V AC) 40 kA (240 V AC) 40 kA (380 V AC) 25 kA (415 V AC) 25 kA (440 V AC) 12.5 kA (500 V AC) 9 kA (525 V AC) 8 kA (690 V AC) 4 kA (250 V DC) 2 Poles in Series 25 kA (500 V DC) 3 Poles in Series 25 kA |
| Rated Ultimate Short-Circuit Breaking Capacity (Icu): | (220 V AC) 40 kA (230 V AC) 40 kA (240 V AC) 40 kA (380 V AC) 25 kA (415 V AC) 25 kA (440 V AC) 25 kA (500 V AC) 18 kA (525 V AC) 8 kA (690 V AC) 4 kA (250 V DC) 2 Poles in Series 25 kA (500 V DC) 3 Poles in Series 25 kA |
| Rated Uninterrupted Current (Iu): | 160 A |
| Rated Voltage (Ur): | 690 V |
| Recommended Screw Driver: | Main Circuit M6 |
| Release: | TMD |
| Release Type: | TM |
| Setting Range: | 28…40 A |
| Short-Circuit Performance Level: | C |
| Standards: | IEC60947-2 |
| Sub-type: | XT1 |
| Terminal Connection Type: | Front |
| Terminal Type: | Bolt |
| Tightening Torque: | 6 N·m |
| Certificates and Declarations | |
| ATEX Certificate: | No certification needed |
| Data Sheet, Technical Information: | 1SDC210100D0206 1SDC210099D0206 |
| Declaration of Conformity – CE: | 9AKK106713A5532 |
| GL Certificate: | 1SDL000163R0103 |
| LR Certificate: | 1SDL000163R0100 |
| UL Certificate: | No certification needed |
| VDE Certificate: | No certification needed |
| Dimension Diagram: | 1SDH000719R0100 |
| Mechanical Drawings: | 1SDH000719R0100 |
| Wiring Diagram: | 1SDM000068R0001 |
| Instructions and Manuals: | 1SDH000719R0001 |
| Classifications | |
| ETIM 8: | EC000228 – Power circuit-breaker for trafo/generator/installation protection |
| ETIM 9: | EC000228 – Power circuit-breaker for trafo/generator/installation protection |
| Object Classification Code: | Q |
| UNSPSC: | 39120000 |
| WEEE Category: | 5. Small Equipment (No External Dimension More Than 50 cm) |
| eClass: | V11.1 : 27370409 |