| ABB EcoSolutions | |
| ABB EcoSolutions: | Yes |
| Circular Value | |
| Circular Design Principles Recyclability Rate: | Design for Closing Resource Loops – Standard EN45555 – 55.9 % |
| End of Life Instructions: | 9AKK108468A2347 |
| Group Waste to Landfill Target: | UL 2799 Zero Waste To Landfill Validation available |
| Eco Transparency | |
| Environmental Product Declaration – EPD: | 9AKK108468A1890 9AKK108468A7793 |
| Environmental | |
| Environmental Information: | 9AKK108467A6707 |
| Material Compliance | |
| REACH Declaration: | 9AKK108466A1425 |
| RoHS Information: | 9AKK108466A1424 |
| RoHS Status: | Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019 |
| Conflict Minerals Reporting Template (CMRT): | 9AKK108467A5658 |
| Toxic Substances Control Act – TSCA: | 9AKK108467A8326 |
| SCIP: | 62bbce4d-080f-4d86-9d81-b900472c629b Italy (IT) |
| Simplified SCIP: | 479f51fc-294e-4dd6-895e-e829ac0b81e1 Poland (PL) 55b895cf-afa9-4baa-9ab8-1a4e51392550 France (FR) 2ff5a69b-4b7b-4aa0-aaca-580fc33c244a Sweden (SE) c6d4ab2c-2876-4862-a074-95b19ec7a5db Germany (DE) 0564b919-5fdc-4fac-83de-b868b1cf479a Hungary (HU) 30e03275-97e9-43fd-950a-c41477e4f724 Hungary (HU) 3f2635c8-8b68-4411-83d9-38c9ab429218 Germany (DE) b059d5cc-c10c-470b-b91a-8c5fba296910 Poland (PL) 352d50a8-6362-4006-aab7-149019f3a151 Netherlands (NL) ddd923fd-da41-4ae8-91dc-fc97e42eee32 Bulgaria (BG) 9afe4ace-6b6c-49ee-9880-5a365d758903 Belgium (BE) 752d4914-a434-422a-bf45-6467cc38fa93 Spain (ES) a1bdc34a-9ba6-4c5a-8124-e25737c8623e Sweden (SE) 59c45024-6b55-426e-939d-feef3baa0f33 Poland (PL) 76b7bfaf-8556-461f-9862-8cef9d327ecc Norway (NO) 99ecf823-5fdb-4e14-abf2-810261830484 Finland (FI) 7385ef91-2bd9-48a2-8c37-7dd4b14991c9 Belgium (BE) d34e8069-d92d-4d9f-bce5-dfbd55f31e6d Germany (DE) f93d3bb5-6874-4bfb-bc53-7426f177f77d Greece (GR) 264b5eaa-e9ff-4830-b97e-bc7991ec2f8c Portugal (PT) abf903d0-ee30-4afb-bf25-aff4181635e9 Germany (DE) 6ac49de9-8f8e-476d-816d-1483a6ffa760 Croatia (HR) 0acc9fa6-ca0e-4ffb-b2ca-63b2beae6d3f Czech Republic (CZ) 3e3ac273-7275-4ca1-b62e-88cce695e24b Germany (DE) 34880d7b-26c8-439a-b0c3-541a658baddc Estonia (EE) eb832ab9-ab8e-4a4f-8384-e601ee2473be Denmark (DK) |
| Ordering | |
| Order Code US and Canada: | XT1CE3080AFF000XXX |
| E-Number (Finland): | 3638627 |
| EAN: | 8015644695200 |
| Minimum Order Quantity: | 1 piece |
| Customs Tariff Number: | 85362090 |
| Dimensions | |
| Product Net Width: | 76.2 mm |
| Product Net Height: | 130 mm |
| Product Net Depth / Length: | 70 mm |
| Product Net Weight: | 1.1 kg |
| Container Information | |
| Package Level 1 Units: | box 1 piece |
| Package Level 1 Width: | 128 mm |
| Package Level 1 Height: | 135 mm |
| Package Level 1 Depth / Length: | 143 mm |
| Package Level 1 Gross Weight: | 1.133 kg |
| Package Level 1 EAN: | 8015644695200 |
| Additional Information | |
| Circuit Breaker Type to be Associated: | Power Distribution |
| Product Main Type: | SACE Tmax XT |
| Product Name: | Moulded Case Circuit Breaker |
| Product Type: | Automatic Circuit Breaker |
| Version: | F |
| CAD Dimensional Drawing: | 1SDH001295R0008 |
| Technical | |
| Connecting Capacity Main Circuit: | Busbar 45.5 … 80 mm² |
| Current Type: | AC/DC |
| Electrical Durability: | 120 cycles per hour 8000 cycle |
| Mechanical Durability: | 240 cycles per hour 25000 cycle |
| Number of Poles: | 3 |
| Opening Time: | CB with SOR 15 ms CB with UVR 15 ms |
| Order Multiple: | 1 piece |
| Power Loss: | at Rated Operating Conditions per Pole 4.8 W |
| Rated Current (In): | 80 A |
| Rated Frequency (f): | 50 / 60 Hz |
| Rated Impulse Withstand Voltage (Uimp): | 8 kV |
| Rated Instantaneous Short-Circuit Current Setting (Ii): | 800 A |
| Rated Insulation Voltage (Ui): | 800 V |
| Rated Operational Voltage: | 690 V AC 500 V DC |
| Rated Service Short-Circuit Breaking Capacity (Ics): | (220 V AC) 40 kA (230 V AC) 40 kA (240 V AC) 40 kA (380 V AC) 25 kA (415 V AC) 25 kA (440 V AC) 12.5 kA (500 V AC) 9 kA (525 V AC) 8 kA (690 V AC) 4 kA (250 V DC) 2 Poles in Series 25 kA (500 V DC) 3 Poles in Series 25 kA |
| Rated Ultimate Short-Circuit Breaking Capacity (Icu): | (220 V AC) 40 kA (230 V AC) 40 kA (240 V AC) 40 kA (380 V AC) 25 kA (415 V AC) 25 kA (440 V AC) 25 kA (500 V AC) 18 kA (525 V AC) 8 kA (690 V AC) 4 kA (250 V DC) 2 Poles in Series 25 kA (500 V DC) 3 Poles in Series 25 kA |
| Rated Uninterrupted Current (Iu): | 160 A |
| Rated Voltage (Ur): | 690 V |
| Recommended Screw Driver: | Main Circuit M6 |
| Release: | TMD |
| Release Type: | TM |
| Setting Range: | 56…80 A |
| Short-Circuit Performance Level: | C |
| Standards: | IEC60947-2 |
| Sub-type: | XT1 |
| Terminal Connection Type: | Front |
| Terminal Type: | Bolt |
| Tightening Torque: | 6 N·m |
| Certificates and Declarations | |
| ATEX Certificate: | No certification needed |
| Data Sheet, Technical Information: | 1SDC210100D0206 1SDC210099D0206 |
| Declaration of Conformity – CE: | 9AKK106713A5532 |
| GL Certificate: | 1SDL000163R0103 |
| LR Certificate: | 1SDL000163R0100 |
| UL Certificate: | No certification needed |
| VDE Certificate: | No certification needed |
| Dimension Diagram: | 1SDH000719R0100 |
| Mechanical Drawings: | 1SDH000719R0100 |
| Wiring Diagram: | 1SDM000068R0001 |
| Instructions and Manuals: | 1SDH000719R0001 |
| Classifications | |
| ETIM 8: | EC000228 – Power circuit-breaker for trafo/generator/installation protection |
| ETIM 9: | EC000228 – Power circuit-breaker for trafo/generator/installation protection |
| Object Classification Code: | Q |
| UNSPSC: | 39120000 |
| WEEE Category: | 5. Small Equipment (No External Dimension More Than 50 cm) |
| eClass: | V11.1 : 27370409 |