ABB XT1N 160 TMD 40-450 4p F F

General Information

Extended Product Type: XT1N 160 TMD 40-450 4p F F
Product ID: 1SDA067420R1
EAN: 8015644013141
Catalog Description: XT1N 160 TMD 40-450 4p F F
Long Description: C.BREAKER TMAX XT1N 160 FIXED FOUR-POLE WITH FRONT TERMINALS AND THERMOMAGNETIC RELEASE TMD R 40-450 A

Description

ABB EcoSolutions
ABB EcoSolutions: Yes
Circular Value
Circular Design Principles Recyclability Rate: Design for Closing Resource Loops – Standard EN45555 – 55.9 %
End of Life Instructions: 9AKK108468A2347
Group Waste to Landfill Target: UL 2799 Zero Waste To Landfill Validation available
Eco Transparency
Environmental Product Declaration – EPD: 9AKK108468A1890
9AKK108468A7793
Environmental
Environmental Information: 9AKK108467A6707
Material Compliance
REACH Declaration: 9AKK108466A1425
RoHS Information: 9AKK108466A1424
RoHS Status: Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019
Conflict Minerals Reporting Template (CMRT): 9AKK108467A5658
Toxic Substances Control Act – TSCA: 9AKK108467A8326
SCIP: bb45f1da-8cc1-46d6-83b6-a1b3baf6ac67 Italy (IT)
Simplified SCIP: 06a16227-9a23-4383-a0e5-7b7175dca117 Belgium (BE)
e56b0d92-46c4-4721-970f-3af3b889864e Spain (ES)
0fc7925a-dcc0-4543-9d65-15d0e9522adb France (FR)
6d3efead-2c74-4337-8835-080e289b47a4 Germany (DE)
d23204a9-469f-4a2e-a9c1-81106c28d8cd Czech Republic (CZ)
dd717899-506f-4f7c-8d96-b08a31f29bda Croatia (HR)
95ca9790-495b-479b-8d24-2348be24b5cc Germany (DE)
fefd45ff-5354-4cb5-9ee8-8fd8e9e845e6 Denmark (DK)
a8c86710-5d69-43e7-953c-796232bdbcd1 Germany (DE)
624a7f18-ebf7-436d-88ca-75a07a63c7ab Sweden (SE)
586a90a7-18f8-455d-98a8-f4e432b26fe3 Poland (PL)
8e60a9c0-db05-4620-8a18-6ab9d9a3be1e Estonia (EE)
3c533264-addc-44ac-8251-fb304cb503b6 Greece (GR)
95a52950-6026-4eaf-a420-63e651313792 Belgium (BE)
f9c309e9-d281-4301-879a-417a66bdbd5c Germany (DE)
1ac3a81d-e4cc-451d-946f-5bce449aa7cf France (FR)
2612acbc-c08b-4c40-9ed5-59287e2be748 Poland (PL)
fe69ad38-e8e0-47bc-a9b7-3c53b49672ae Hungary (HU)
82760656-0550-4b3a-84bc-25a3f98b5c9e Portugal (PT)
bbd1646d-d373-4851-bb91-b2ff51bf9de0 Germany (DE)
b0598f26-f85c-4e4d-97cf-1274950ae30b Sweden (SE)
cf070818-0ede-42d5-b70a-9bb9b0e27a41 Netherlands (NL)
5d2d773d-1c51-4406-8052-2af850322ac6 Norway (NO)
baba48c7-474d-4919-9638-cff3a8cb00cc Hungary (HU)
7268b0d5-b5bf-4500-b2ef-13fc5aea72b8 Finland (FI)
8a4bcb19-74bc-4cb1-bd90-b1a712ead71c Bulgaria (BG)
843937e6-dbd9-4007-acff-baf15d2b4c44 Poland (PL)
Ordering
Order Code US and Canada: XT1NE4040AFF000XXX
E-Number (Finland): 3640540
EAN: 8015644013141
Minimum Order Quantity: 1 piece
Customs Tariff Number: 85362090
Dimensions
Product Net Width: 101.6 mm
Product Net Height: 130 mm
Product Net Depth / Length: 70 mm
Product Net Weight: 1.4 kg
Container Information
Package Level 1 Units: box 1 piece
Package Level 1 Width: 128 mm
Package Level 1 Height: 135 mm
Package Level 1 Depth / Length: 143 mm
Package Level 1 Gross Weight: 1.43 kg
Package Level 1 EAN: 8015644013141
Additional Information
Circuit Breaker Type to be Associated: Power Distribution
Product Main Type: SACE Tmax XT
Product Name: Moulded Case Circuit Breaker
Product Type: Automatic Circuit Breaker
Version: F
CAD Dimensional Drawing: 1SDH001295R0080
Technical
Connecting Capacity Main Circuit: Busbar 45.5 … 80 mm²
Current Type: AC/DC
Electrical Durability: 120 cycles per hour
8000 cycle
Mechanical Durability: 240 cycles per hour
25000 cycle
Number of Poles: 4
Opening Time: CB with SOR 15 ms
CB with UVR 15 ms
Order Multiple: 1 piece
Power Loss: at Rated Operating Conditions per Pole 2.6 W
Rated Current (In): 40 A
Rated Frequency (f): 50 / 60 Hz
Rated Impulse Withstand Voltage (Uimp): 8 kV
Rated Instantaneous Short-Circuit Current Setting (Ii): 450 A
Rated Insulation Voltage (Ui): 800 V
Rated Operational Voltage: 690 V AC
500 V DC
Rated Service Short-Circuit Breaking Capacity (Ics): (220 V AC) 50 kA
(230 V AC) 50 kA
(240 V AC) 50 kA
(380 V AC) 36 kA
(415 V AC) 36 kA
(440 V AC) 18 kA
(500 V AC) 15 kA
(525 V AC) 11 kA
(690 V AC) 5 kA
(250 V DC) 2 Poles in Series 36 kA
(500 V DC) 3 Poles in Series 36 kA
Rated Ultimate Short-Circuit Breaking Capacity (Icu): (220 V AC) 65 kA
(230 V AC) 65 kA
(240 V AC) 65 kA
(380 V AC) 36 kA
(415 V AC) 36 kA
(440 V AC) 36 kA
(500 V AC) 30 kA
(525 V AC) 22 kA
(690 V AC) 6 kA
(250 V DC) 2 Poles in Series 36 kA
(500 V DC) 3 Poles in Series 36 kA
Rated Uninterrupted Current (Iu): 160 A
Rated Voltage (Ur): 690 V
Recommended Screw Driver: Main Circuit M6
Release: TMD
Release Type: TM
Setting Range: 28…40 A
Short-Circuit Performance Level: N
Standards: IEC60947-2
Sub-type: XT1
Terminal Connection Type: Front
Terminal Type: Bolt
Tightening Torque: 6 N·m
Certificates and Declarations
ATEX Certificate: No certification needed
Data Sheet, Technical Information: 1SDC210100D0206
1SDC210099D0206
Declaration of Conformity – CE: 9AKK106713A5532
GL Certificate: 1SDL000163R0103
LR Certificate: 1SDL000163R0100
UL Certificate: No certification needed
VDE Certificate: No certification needed
Dimension Diagram: 1SDH000719R0100
Mechanical Drawings: 1SDH000719R0100
Wiring Diagram: 1SDM000068R0001
Instructions and Manuals: 1SDH000719R0001
Classifications
ETIM 8: EC000228 – Power circuit-breaker for trafo/generator/installation protection
ETIM 9: EC000228 – Power circuit-breaker for trafo/generator/installation protection
Object Classification Code: Q
UNSPSC: 39120000
WEEE Category: 5. Small Equipment (No External Dimension More Than 50 cm)
eClass: V11.1 : 27370409

Downloads

Datasheet