Description
| ABB EcoSolutions | |
| ABB EcoSolutions: | Yes |
| Circular Value | |
| Circular Design Principles Recyclability Rate: | Design for Closing Resource Loops – Standard EN45555 – 55.9 % |
| End of Life Instructions: | 9AKK108468A2347 |
| Group Waste to Landfill Target: | UL 2799 Zero Waste To Landfill Validation available |
| Eco Transparency | |
| Environmental Product Declaration – EPD: | 9AKK108468A1890 9AKK108468A7793 |
| Environmental | |
| Environmental Information: | 9AKK108467A6707 |
| Material Compliance | |
| REACH Declaration: | 9AKK108466A1425 |
| RoHS Information: | 9AKK108466A1424 |
| RoHS Status: | Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019 |
| Conflict Minerals Reporting Template (CMRT): | 9AKK108467A5658 |
| Toxic Substances Control Act – TSCA: | 9AKK108467A8326 |
| SCIP: | 065d76dc-4866-4238-a2d1-09fa42dd2cb5 Italy (IT) |
| Simplified SCIP: | 607d8d60-0432-4779-831c-4f1cb587e313 Hungary (HU) a36a9d8e-cba2-455a-8adb-f44f4669a25e Finland (FI) c8b5f88e-4d8a-406b-a3d3-5badce908e68 Denmark (DK) cb4a7fb7-1f02-45bf-9367-5c4fe290cdea France (FR) 8dc3f902-f0b6-48ba-bae5-a49cce8d8462 Belgium (BE) b72fb2b8-bf54-4eef-872b-88cbcdf30a5f Spain (ES) 87f04c8e-0af0-4cb8-bd8a-ab459a84d5f6 Germany (DE) b9953d49-c7d2-42e5-b710-f9ef62f4b854 Czech Republic (CZ) 4963115d-b548-4ad5-9631-12086f5f7e35 Germany (DE) e8f1d9f5-91c7-4768-b5e9-b474e4b3fb95 Sweden (SE) 260dacaa-90cb-47b4-baf1-2c2cc1a64e36 Germany (DE) c73e3a3a-bd80-489c-a70e-0f469c898ccb Croatia (HR) c5d8b5ba-2087-4ce8-b656-93fbaa27321b Germany (DE) 17c3b421-ef43-4005-8a15-b5bf16edeb46 Portugal (PT) 5a1bc370-26fe-4ffa-b478-e6248af0bd28 Poland (PL) 625f19c9-b05f-436b-b11f-abe5355adc76 Hungary (HU) 439f4bd8-4fa2-4ff4-b975-4912a8501d15 Norway (NO) 2c15a82b-b14e-47d0-87ed-85e76da4d129 Bulgaria (BG) 9b94776b-9a9c-436a-aab7-676f7c12eb05 Poland (PL) 01dffaa7-71b7-4701-97dc-50013b1174a0 France (FR) 03d4a0ba-21d9-44bb-88d4-e1bb315ff13f Greece (GR) 13433f2a-a7e3-4970-a905-90c47ef541c0 Germany (DE) 9bde9240-c090-427e-aeb9-7f2e6ead1b43 Netherlands (NL) 002c0ab8-38e1-4cce-9a7c-4969801dfc6c Sweden (SE) 06d4c4c6-4286-4c66-b3ff-835ae8c09f17 Estonia (EE) d4131551-72e6-40c6-a5f0-1d87c7aec611 Belgium (BE) e973c807-6821-4c1f-8fc6-1e3ea32313e1 Poland (PL) |
| Ordering | |
| Order Code US and Canada: | XT1NE3020AFF000XXX |
| E-Number (Finland): | 3640532 |
| EAN: | 8015644873462 |
| Minimum Order Quantity: | 1 piece |
| Customs Tariff Number: | 85362090 |
| Dimensions | |
| Product Net Width: | 76.2 mm |
| Product Net Height: | 130 mm |
| Product Net Depth / Length: | 70 mm |
| Product Net Weight: | 1 kg |
| Container Information | |
| Package Level 1 Units: | box 1 piece |
| Package Level 1 Width: | 128 mm |
| Package Level 1 Height: | 135 mm |
| Package Level 1 Depth / Length: | 143 mm |
| Package Level 1 Gross Weight: | 1.1 kg |
| Package Level 1 EAN: | 8015644873462 |
| Additional Information | |
| Circuit Breaker Type to be Associated: | Power Distribution |
| Product Main Type: | SACE Tmax XT |
| Product Name: | Moulded Case Circuit Breaker |
| Product Type: | Automatic Circuit Breaker |
| Version: | F |
| CAD Dimensional Drawing: | 1SDH001295R0008 |
| Technical | |
| Current Type: | AC/DC |
| Electrical Durability: | 120 cycles per hour 8000 cycle |
| Mechanical Durability: | 240 cycles per hour 25000 cycle |
| Number of Poles: | 3 |
| Opening Time: | CB with SOR 15 ms CB with UVR 15 ms |
| Order Multiple: | 1 piece |
| Rated Current (In): | 20 A |
| Rated Impulse Withstand Voltage (Uimp): | 8 kV |
| Rated Instantaneous Short-Circuit Current Setting (Ii): | 450 A |
| Rated Insulation Voltage (Ui): | 800 V |
| Rated Operational Voltage: | 690 V AC 500 V DC |
| Rated Service Short-Circuit Breaking Capacity (Ics): | (220 V AC) 50 kA (230 V AC) 50 kA (240 V AC) 50 kA (380 V AC) 36 kA (415 V AC) 36 kA (440 V AC) 18 kA (500 V AC) 15 kA (525 V AC) 11 kA (690 V AC) 5 kA (250 V DC) 2 Poles in Series 36 kA (500 V DC) 3 Poles in Series 36 kA |
| Rated Ultimate Short-Circuit Breaking Capacity (Icu): | (220 V AC) 65 kA (230 V AC) 65 kA (240 V AC) 65 kA (380 V AC) 36 kA (415 V AC) 36 kA (440 V AC) 36 kA (500 V AC) 30 kA (525 V AC) 22 kA (690 V AC) 6 kA (250 V DC) 2 Poles in Series 36 kA (500 V DC) 3 Poles in Series 36 kA |
| Rated Uninterrupted Current (Iu): | 160 A |
| Rated Voltage (Ur): | 690 V |
| Release: | TMF |
| Release Type: | TM |
| Setting Range: | 20 A |
| Short-Circuit Performance Level: | N |
| Standards: | IEC60947-2 |
| Sub-type: | XT1 |
| Terminal Connection Type: | Front |
| Certificates and Declarations | |
| Data Sheet, Technical Information: | 1SDC210100D0206 1SDC210099D0206 |
| Declaration of Conformity – CE: | 9AKK106713A5532 |
| Mechanical Drawings: | 1SDH000719R0100 |
| Wiring Diagram: | 1SDM000068R0001 |
| Instructions and Manuals: | 1SDH000719R0001 |
| Classifications | |
| ETIM 8: | EC000228 – Power circuit-breaker for trafo/generator/installation protection |
| ETIM 9: | EC000228 – Power circuit-breaker for trafo/generator/installation protection |
| WEEE Category: | 5. Small Equipment (No External Dimension More Than 50 cm) |
| eClass: | V11.1 : 27370409 |