Description
| ABB EcoSolutions | |
| ABB EcoSolutions: | Yes |
| Circular Value | |
| Circular Design Principles Recyclability Rate: | Design for Closing Resource Loops – Standard EN45555 – 55.70 % |
| End of Life Instructions: | 9AKK108468A2348 |
| Group Waste to Landfill Target: | UL 2799 Zero Waste To Landfill Validation available |
| Eco Transparency | |
| Environmental Product Declaration – EPD: | 9AKK108469A1856 9AKK108468A1891 |
| Environmental | |
| Environmental Information: | 9AKK108467A6707 |
| Material Compliance | |
| REACH Declaration: | 9AKK108466A1425 |
| RoHS Information: | 9AKK108466A1424 |
| RoHS Status: | Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019 |
| Conflict Minerals Reporting Template (CMRT): | 9AKK108467A5658 |
| Toxic Substances Control Act – TSCA: | 9AKK108467A8326 |
| SCIP: | cfc84dde-e61a-4e38-b07f-5da4036ea9a4 Italy (IT) |
| Simplified SCIP: | 60f3a5ce-a473-4456-911e-ac0a2deb4152 Germany (DE) 1b2e7963-dfa1-45d9-8b2a-1b6c5172378c Norway (NO) 588d33f0-5dfd-4182-b24c-36b94e148703 Finland (FI) 0e17691f-b006-45f2-be24-b655b0b8b097 Netherlands (NL) b63bc7d2-c6c0-49d3-8715-65f45ea937b8 Germany (DE) 8c45bec7-2fcc-414a-bdd3-dcde1acdd39e Denmark (DK) 943b1b2a-c881-4828-ae9a-22285d4da212 Netherlands (NL) ec4c3592-cc19-486b-8a7e-361979719560 Netherlands (NL) 2b42ea61-971f-4447-815c-868e808a63ba Estonia (EE) a64fd534-cdf4-4cbd-90c7-a143c153246b Greece (GR) 3c0b8a52-0cae-4561-a3a3-7d51b13a9475 Portugal (PT) e5352635-40ab-4bf9-a257-998d8f2d269e Germany (DE) 7386e9a4-136b-42a6-be67-482534d5c84b Croatia (HR) 3d07411e-b413-40da-9418-b392c93f18ed Czech Republic (CZ) 371c7095-86b9-4941-b118-3f9133d596ff Poland (PL) 0ff16924-d336-4759-a47e-afc804c32099 Germany (DE) 76299180-5c14-4f42-b82b-73c785ad9452 Germany (DE) ef2cfb62-d9aa-4d30-92d2-589ab8a12a7e France (FR) e8206767-1d0c-483e-96b0-8a65ccf203ea Netherlands (NL) e1342d0e-8629-4bca-bd3d-0380a997960c Spain (ES) 3044fef1-e5d7-4162-b7bf-6a52a29f8b38 Netherlands (NL) 3f0c10fe-2ed4-4969-86dc-272c9282ea75 Bulgaria (BG) d742ac5a-846e-4722-9020-c02906324ba3 Sweden (SE) fc541581-da0a-4833-877d-70aee274cfc8 Poland (PL) 64835302-4bcd-4d88-8e7a-cf1fc265821c France (FR) 355b4542-96dd-4173-b98c-0dfdd78d83d4 Sweden (SE) bcda9fcf-6239-4554-b97a-c77ffb6efa4d Poland (PL) |
| Ordering | |
| Order Code US and Canada: | XT2HE3025AFF000XXX |
| E-Number (Finland): | 3638600 |
| EAN: | 8015644014926 |
| Minimum Order Quantity: | 1 piece |
| Customs Tariff Number: | 85362090 |
| Dimensions | |
| Product Net Width: | 90 mm |
| Product Net Height: | 130 mm |
| Product Net Depth / Length: | 82.5 mm |
| Product Net Weight: | 1.1 kg |
| Container Information | |
| Package Level 1 Units: | box 1 piece |
| Package Level 1 Width: | 131 mm |
| Package Level 1 Height: | 212 mm |
| Package Level 1 Depth / Length: | 147 mm |
| Package Level 1 Gross Weight: | 1.2 kg |
| Package Level 1 EAN: | 8015644014926 |
| Additional Information | |
| Circuit Breaker Type to be Associated: | Power Distribution |
| Product Main Type: | SACE Tmax XT |
| Product Name: | Moulded Case Circuit Breaker |
| Product Type: | Automatic Circuit Breaker |
| Version: | F |
| CAD Dimensional Drawing: | 1SDH002230A1001 |
| Technical | |
| Connecting Capacity Main Circuit: | Busbar 32.5..100 mm² |
| Current Type: | AC/DC |
| Electrical Durability: | 120 cycles per hour 8000 cycle |
| Mechanical Durability: | 240 cycles per hour 25000 cycle |
| Number of Poles: | 3 |
| Opening Time: | CB with SOR 15 ms CB with UVR 15 ms |
| Order Multiple: | 1 piece |
| Power Loss: | at Rated Operating Conditions per Pole 2 W |
| Rated Current (In): | 25 A |
| Rated Frequency (f): | 50 / 60 Hz |
| Rated Impulse Withstand Voltage (Uimp): | 8 kV |
| Rated Instantaneous Short-Circuit Current Setting (Ii): | 300 A |
| Rated Insulation Voltage (Ui): | 1000 V |
| Rated Operational Voltage: | 690 V AC 500 V DC |
| Rated Service Short-Circuit Breaking Capacity (Ics): | (220 V AC) 100 kA (230 V AC) 100 kA (240 V AC) 100 kA (380 V AC) 70 kA (415 V AC) 70 kA (440 V AC) 65 kA (500 V AC) 50 kA (525 V AC) 30 kA (690 V AC) 15 kA (250 V DC) 2 Poles in Series 70 kA (500 V DC) 3 Poles in Series 70 kA |
| Rated Ultimate Short-Circuit Breaking Capacity (Icu): | (220 V AC) 100 kA (230 V AC) 100 kA (240 V AC) 100 kA (380 V AC) 70 kA (415 V AC) 70 kA (440 V AC) 65 kA (500 V AC) 50 kA (525 V AC) 30 kA (690 V AC) 15 kA (250 V DC) 2 Poles in Series 70 kA (500 V DC) 3 Poles in Series 70 kA |
| Rated Uninterrupted Current (Iu): | 160 A |
| Rated Voltage (Ur): | 690 V |
| Recommended Screw Driver: | Main Circuit M6 |
| Release: | TMD |
| Release Type: | TM |
| Setting Range: | 17.5…25 A |
| Short-Circuit Performance Level: | H |
| Standards: | IEC60947-2 |
| Sub-type: | XT2 |
| Terminal Connection Type: | Front |
| Terminal Type: | Bolt |
| Tightening Torque: | 6 N·m |
| Certificates and Declarations | |
| ATEX Certificate: | No certification needed |
| Data Sheet, Technical Information: | 1SDC210100D0206 1SDC210099D0206 |
| Declaration of Conformity – CE: | 9AKK106713A5901 |
| GL Certificate: | 1SDL000163R0093 |
| LR Certificate: | 1SDL000163R0100 |
| UL Certificate: | No certification needed |
| VDE Certificate: | No certification needed |
| Dimension Diagram: | 1SDH000721R0100 |
| Mechanical Drawings: | 1SDH000721R0100 |
| Wiring Diagram: | 1SDM000068R0001 |
| Instructions and Manuals: | 1SDH000721R0001 |
| Classifications | |
| ETIM 8: | EC000228 – Power circuit-breaker for trafo/generator/installation protection |
| ETIM 9: | EC000228 – Power circuit-breaker for trafo/generator/installation protection |
| Object Classification Code: | Q |
| UNSPSC: | 39120000 |
| WEEE Category: | 5. Small Equipment (No External Dimension More Than 50 cm) |
| eClass: | V11.1 : 27370409 |