Description
| ABB EcoSolutions | |
| ABB EcoSolutions: | Yes |
| Circular Value | |
| Circular Design Principles Recyclability Rate: | Design for Closing Resource Loops – Standard EN45555 – 55.70 % |
| End of Life Instructions: | 9AKK108468A2348 |
| Group Waste to Landfill Target: | UL 2799 Zero Waste To Landfill Validation available |
| Eco Transparency | |
| Environmental Product Declaration – EPD: | 9AKK108469A1856 9AKK108468A1891 |
| Environmental | |
| Environmental Information: | 9AKK108467A6707 |
| Material Compliance | |
| REACH Declaration: | 9AKK108466A1425 |
| RoHS Information: | 9AKK108466A1424 |
| RoHS Status: | Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019 |
| Conflict Minerals Reporting Template (CMRT): | 9AKK108467A5658 |
| Toxic Substances Control Act – TSCA: | 9AKK108467A8326 |
| SCIP: | ce23f4ae-35ba-49ba-8bcb-1af092fb2c20 Italy (IT) |
| Simplified SCIP: | 2b5eaa92-205a-40b9-bca7-7e52401ac428 France (FR) 23e1caf1-645d-4011-b1bd-567a512901dc Spain (ES) ee5b4bb6-f1fb-4651-a746-778bd2eeb374 Hungary (HU) 8776e078-a8b0-432d-b5bd-b8361a90fe23 Belgium (BE) cafa272f-e73a-473a-8f7f-dc8cd63278f4 Germany (DE) ea8a9633-732a-4fd2-b78c-da111d5b6bbe Czech Republic (CZ) c2ab4b42-18f9-4042-9282-9aae651f22d8 Sweden (SE) 542b5cb7-04e5-4e34-854d-6157c44a31e7 Portugal (PT) 75364400-521b-471c-b1ac-4ffbb6824e70 Denmark (DK) 6239c29b-966e-45a7-b632-beaf0e63c84b Germany (DE) 733b23bd-e75a-4f1a-873a-95c5313bc5b4 Germany (DE) 043c41c4-6240-457e-b330-9093b5fd26c3 Croatia (HR) f60ba0b2-b2ed-48f3-a498-9c2b23430b2b Germany (DE) 1db306bb-beec-4694-aea5-39a6e0bbf82d Norway (NO) 8801ee98-b3a8-4b58-9e4b-67a12206e7ed Netherlands (NL) 095641cf-77ae-4600-bb35-87c96dbe5444 Sweden (SE) aa6fb5a3-0908-467d-a472-03f2f23ade01 Bulgaria (BG) be054cbb-d051-46bf-940d-3051d79d0240 Poland (PL) 19359a19-6b7b-405d-af0d-45756d0b1630 Poland (PL) f31eb2c5-8f6a-4af3-9a27-89b88358c8de Hungary (HU) bee6c10f-1483-4f75-829a-a9a816a20ec9 Poland (PL) c778cea7-8f44-48f5-be7d-61a151c865bf Finland (FI) 633608f6-ccb8-48c3-808c-c45159d9ab2c Estonia (EE) 891d9794-1b6c-40b5-8af5-b35b1da4af6a Belgium (BE) 5a5a49df-463d-4317-9073-0b0d161b6222 Germany (DE) 8d288905-05d5-4fdb-90ba-9570c71f0ab6 Greece (GR) 1bfc0c02-fab0-49b1-8a3c-dfe1a09a50c6 France (FR) |
| Ordering | |
| Order Code US and Canada: | XT2SE3032AFF000XXX |
| E-Number (Finland): | 3638611 |
| EAN: | 8015644014490 |
| Minimum Order Quantity: | 1 piece |
| Customs Tariff Number: | 85362090 |
| Dimensions | |
| Product Net Width: | 90 mm |
| Product Net Height: | 130 mm |
| Product Net Depth / Length: | 82.5 mm |
| Product Net Weight: | 1.4 kg |
| Container Information | |
| Package Level 1 Units: | box 1 piece |
| Package Level 1 Width: | 130 mm |
| Package Level 1 Height: | 208 mm |
| Package Level 1 Depth / Length: | 145 mm |
| Package Level 1 Gross Weight: | 1.664 kg |
| Package Level 1 EAN: | 8015644014490 |
| Additional Information | |
| Circuit Breaker Type to be Associated: | Power Distribution |
| Product Main Type: | SACE Tmax XT |
| Product Name: | Moulded Case Circuit Breaker |
| Product Type: | Automatic Circuit Breaker |
| Version: | F |
| CAD Dimensional Drawing: | 1SDH002230A1001 |
| Technical | |
| Connecting Capacity Main Circuit: | Busbar 32.5..100 mm² |
| Current Type: | AC/DC |
| Electrical Durability: | 120 cycles per hour 8000 cycle |
| Mechanical Durability: | 240 cycles per hour 25000 cycle |
| Number of Poles: | 3 |
| Opening Time: | CB with SOR 15 ms CB with UVR 15 ms |
| Order Multiple: | 1 piece |
| Power Loss: | at Rated Operating Conditions per Pole 2.57 W |
| Rated Current (In): | 32 A |
| Rated Frequency (f): | 50 / 60 Hz |
| Rated Impulse Withstand Voltage (Uimp): | 8 kV |
| Rated Instantaneous Short-Circuit Current Setting (Ii): | 320 A |
| Rated Insulation Voltage (Ui): | 1000 V |
| Rated Operational Voltage: | 690 V AC 500 V DC |
| Rated Service Short-Circuit Breaking Capacity (Ics): | (220 V AC) 85 kA (230 V AC) 85 kA (240 V AC) 85 kA (380 V AC) 50 kA (415 V AC) 50 kA (440 V AC) 50 kA (500 V AC) 36 kA (525 V AC) 25 kA (690 V AC) 12 kA (250 V DC) 2 Poles in Series 50 kA (500 V DC) 3 Poles in Series 50 kA |
| Rated Ultimate Short-Circuit Breaking Capacity (Icu): | (220 V AC) 85 kA (230 V AC) 85 kA (240 V AC) 85 kA (380 V AC) 50 kA (415 V AC) 50 kA (440 V AC) 50 kA (500 V AC) 36 kA (525 V AC) 25 kA (690 V AC) 12 kA (250 V DC) 2 Poles in Series 50 kA (500 V DC) 3 Poles in Series 50 kA |
| Rated Uninterrupted Current (Iu): | 160 A |
| Rated Voltage (Ur): | 690 V |
| Recommended Screw Driver: | Main Circuit M6 |
| Release: | TMD |
| Release Type: | TM |
| Setting Range: | 22.4…32 A |
| Short-Circuit Performance Level: | S |
| Standards: | IEC60947-2 |
| Sub-type: | XT2 |
| Terminal Connection Type: | Front |
| Terminal Type: | Bolt |
| Tightening Torque: | 6 N·m |
| Certificates and Declarations | |
| ATEX Certificate: | No certification needed |
| Data Sheet, Technical Information: | 1SDC210100D0206 1SDC210099D0206 |
| Declaration of Conformity – CE: | 9AKK106713A5901 |
| GL Certificate: | 1SDL000163R0093 |
| LR Certificate: | 1SDL000163R0100 |
| UL Certificate: | No certification needed |
| VDE Certificate: | No certification needed |
| Dimension Diagram: | 1SDH000721R0100 |
| Mechanical Drawings: | 1SDH000721R0100 |
| Wiring Diagram: | 1SDM000068R0001 |
| Instructions and Manuals: | 1SDH000721R0001 |
| Classifications | |
| ETIM 8: | EC000228 – Power circuit-breaker for trafo/generator/installation protection |
| ETIM 9: | EC000228 – Power circuit-breaker for trafo/generator/installation protection |
| Object Classification Code: | Q |
| UNSPSC: | 39120000 |
| WEEE Category: | 5. Small Equipment (No External Dimension More Than 50 cm) |
| eClass: | V11.1 : 27370409 |