Description
| Ordering | |
| Minimum Order Quantity: | 1 piece |
| Customs Tariff Number: | 85364900 |
| Popular Downloads | |
| Instructions and Manuals: | 2CDC106080M6802 |
| Instructions and Manuals (Part 2): | 1SAC200017M0002 |
| Time-Current Characteristic Curve: | 1SAZ300501F0005 |
| Dimension Diagram: | 1SAZ300403F0001 |
| Dimensions | |
| Product Net Width: | 78 mm |
| Product Net Height: | 97 mm |
| Product Net Depth / Length: | 111 mm |
| Product Net Weight: | 0.365 kg |
| Technical | |
| Setting Range: | 45 … 63 A |
| Rated Operational Voltage: | Auxiliary Circuit 440 V DC Auxiliary Circuit 500 V AC Main Circuit 690 V AC Main Circuit 440 V DC |
| Rated Operational Current (Ie): | 63 A |
| Rated Frequency (f): | Auxiliary Circuit 50 Hz Auxiliary Circuit 60 Hz Auxiliary Circuit DC Main Circuit 60 Hz Main Circuit 50 Hz Main Circuit DC |
| Rated Impulse Withstand Voltage (Uimp): | Auxiliary Circuit 6 kV Main Circuit 6 kV |
| Rated Insulation Voltage (Ui): | 690 V |
| Number of Poles: | 3 |
| Number of Auxiliary Contacts NC: | 1 |
| Number of Auxiliary Contacts NO: | 1 |
| Number of Protected Poles: | 3 |
| Conventional Free-air Thermal Current (Ith): | Auxiliary Circuit NC 5 A Auxiliary Circuit NO 5 A |
| Rated Operational Current AC-15 (Ie): | (120 V) NC 3 A (120 V) NO 1.5 A (240 V) NC 3 A (240 V) NO 1.2 A (400 V) NC 0.75 A (400 V) NO 0.37 A (440 V) NC 0.75 A (440 V) NO 0.37 A (500 V) NC 0.3 A (500 V) NO 0.25 A |
| Rated Operational Current DC-13 (Ie): | (125 V) NC 0.25 A (125 V) NO 0.25 A (24 V) NC 1.25 A (24 V) NO 1.25 A (250 V) NC 0.12 A (250 V) NO 0.04 A (60 V) NC 0.25 A (60 V) NO 0.25 A |
| Degree of Protection: | IP20 Housing IP20 Main Circuit Terminals IP10 |
| Pollution Degree: | 3 |
| Connecting Capacity Auxiliary Circuit: | Flexible with Ferrule 1/2x 0.75 … 2.5 mm² Flexible 1/2x 0.75 … 2.5 mm² Rigid 1/2x 0.75 … 4 mm² |
| Connecting Capacity Main Circuit: | Flexible with Ferrule 1x 2.5 … 25 mm² Flexible with Ferrule 2x 2.5 … 10 mm² Rigid 1x 2.5 … 25 mm² Rigid 2x 2.5 … 16 mm² |
| Tightening Torque: | Auxiliary Circuit 1 … 1.3 N·m Main Circuit 4.5 N·m |
| Wire Stripping Length: | Auxiliary Circuit 9 mm Main Circuit 14 mm |
| Recommended Screw Driver: | Auxiliary Circuit Pozidriv 1 Main Circuit Pozidriv 2 |
| Mounting Position: | any |
| Power Loss: | at Rated Operating Conditions per Pole 1.9 … 3.8 W |
| Suitable For: | A95 A110 AE95 AE110 |
| Standards: | IEC/EN 60947-1 IEC/EN 60947-4-1 IEC/EN 60947-5-1 UL 60947-1 UL 60947-4-1 |
| Technical UL/CSA | |
| Maximum Operating Voltage UL/CSA: | Main Circuit 600 V AC |
| Contact Rating UL/CSA: | (NC:) B600 (NO:) C600 |
| Connecting Capacity Main Circuit UL/CSA: | Flexible 1/2x 8-1 AWG Stranded 1/2x 8-1 AWG |
| Connecting Capacity Auxiliary Circuit UL/CSA: | Flexible 1/2x 18-14 AWG Stranded 1/2x 18-14 AWG |
| Tightening Torque UL/CSA: | Auxiliary Circuit 12 in·lb Main Circuit 40 in·lb |
| Environmental | |
| Ambient Air Temperature: | Operation -25 … +55 °C Operation Compensated -25 … +55 °C Storage -40 … +70 °C |
| Ambient Air Temperature Compensation: | Yes |
| Maximum Operating Altitude Permissible: | 2000 m |
| Resistance to Shock acc. to IEC 60068-2-27: | 11 ms Pulse 12g 25g 2 shocks 13 ms |
| Resistance to Vibrations: | 20 Cycles with Load 0.8 In: 5g 5 … 150 … 5 Hz |
| RoHS Status: | Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019 |
| Toxic Substances Control Act – TSCA: | 2CMT2023-006525 |
| Material Compliance | |
| REACH Declaration: | 2CMT2021-006202 |
| RoHS Information: | 2CMT2021-006277 |
| RoHS Status: | Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019 |
| Toxic Substances Control Act – TSCA: | 2CMT2023-006525 |
| WEEE B2C / B2B: | Business To Business |
| WEEE Category: | 5. Small Equipment (No External Dimension More Than 50 cm) |
| Certificates and Declarations | |
| ABS Certificate: | 1SAA941000-0102 |
| BV Certificate: | 1SAA941000-0201 |
| CB Certificate: | 1SAA941017-2001 |
| CQC Certificate: | CQC2016010309922938 |
| Declaration of Conformity – CCC: | 2020980304001323 |
| Declaration of Conformity – CE: | 1SAD101100-3509 |
| Declaration of Conformity – UKCA: | 1SAD201100-3509 |
| DNV Certificate: | 1SAA941000-0304 |
| DNV GL Certificate: | 1SAA941000-0304 |
| EAC Certificate: | 1SAA941002-2702 |
| GL Certificate: | 1SAA941000-0304 |
| LR Certificate: | 1SAA941000-0504 |
| RMRS Certificate: | 1SAA941000-0704 |
| UL Certificate: | E48139-19960918 |
| Container Information | |
| Package Level 1 Units: | 1 piece |
| Package Level 1 Width: | 105 mm |
| Package Level 1 Height: | 90 mm |
| Package Level 1 Depth / Length: | 125 mm |
| Package Level 1 Gross Weight: | 0.405 kg |
| Package Level 1 EAN: | 4013614216770 |
| Package Level 2 Units: | 16 piece |
| Package Level 2 Width: | 280 mm |
| Package Level 2 Height: | 210 mm |
| Package Level 2 Depth / Length: | 395 mm |
| Package Level 2 Gross Weight: | 8.786 kg |
| Package Level 2 EAN: | 4013614494024 |
| Classifications | |
| Object Classification Code: | F |
| ETIM 4: | EC000106 – Thermal overload relay |
| ETIM 5: | EC000106 – Thermal overload relay |
| ETIM 6: | EC000106 – Thermal overload relay |
| ETIM 7: | EC000106 – Thermal overload relay |
| ETIM 8: | EC000106 – Thermal overload relay |
| eClass: | V11.0 : 27371501 |
| UNSPSC: | 39122330 |
| IDEA Granular Category Code (IGCC): | 5366 >> Thermal overload relay |
| E-Number (Finland): | 3709353 |