ABB E16DU-18.9 Electronic Overload Relay 5.7 … 18.9 A

General Information

Extended Product Type: E16DU-18.9
Product ID: 1SAX111001R1105
EAN: 4013614395260
Catalog Description: E16DU-18.9 Electronic Overload Relay 5.7 … 18.9 A
Long Description: The E16DU-18.9 is an self-supplied electronic overload relay, which means no extra external supply is needed. It offers reliable and fast protection for motors in the event of overload or phase failure. Easy to use like a thermal overload relay and compatible with standard motor applications, the electronic overload relay is convincing, above all, due to its wide setting range, high accuracy, high operational temperature range and the possibility to select a trip class (10E, 20E, 30E). Further features are the temperature compensation, trip contact (NC), signal contact (NO), automatic- or manual reset selectable, trip-free mechanism, STOP- and Test function and a trip indication. The overload relays are connected directly to the contactors. Single mounting kits are available as accessory.

Description

Ordering
Minimum Order Quantity: 1 piece
Customs Tariff Number: 85364900
Popular Downloads
Instructions and Manuals: 2CDC107019M5502
Instructions and Manuals (Part 2): 1SAC200017M0002
Time-Current Characteristic Curve: 1SAX100502F0002
1SAX100508F0001
CAD Dimensional Drawing: 2CDC001079B0201
Dimension Diagram: 1SAX100402F0001
1SAX100401F0001
Dimensions
Product Net Width: 44.4 mm
Product Net Height: 74.6 mm
Product Net Depth / Length: 57 mm
Product Net Weight: 0.15 kg
Technical
Setting Range: 5.7 … 18.9 A
Rated Operational Voltage: Auxiliary Circuit 600 V AC/DC
Main Circuit 690 V AC
Rated Operational Current (Ie): 18.9 A
Rated Frequency (f): Auxiliary Circuit 50 Hz
Auxiliary Circuit 60 Hz
Auxiliary Circuit DC
Main Circuit 50 Hz
Main Circuit 60 Hz
Rated Impulse Withstand Voltage (Uimp): Auxiliary Circuit 6 kV
Main Circuit 6 kV
Rated Insulation Voltage (Ui): 690 V
Number of Poles: 3
Number of Auxiliary Contacts NC: 1
Number of Auxiliary Contacts NO: 1
Number of Protected Poles: 3
Conventional Free-air Thermal Current (Ith): Auxiliary Circuit NC 6 A
Auxiliary Circuit NO 6 A
Rated Operational Current AC-15 (Ie): (240 V) NC 3 A
(240 V) NO 3 A
(400 V) NC 1.1 A
(400 V) NO 1.1 A
(500 V) NC 0.72 A
(500 V) NO 0.72 A
Rated Operational Current DC-13 (Ie): (125 V) NC 0.55 A
(125 V) NO 0.5 A
(24 V) NC 1.5 A
(24 V) NO 1.5 A
(250 V) NC 0.27 A
(250 V) NO 0.27 A
(60 V) NC 0.55 A
(60 V) NO 0.55 A
Degree of Protection: IP20
Pollution Degree: 3
Connecting Capacity Auxiliary Circuit: Flexible with Ferrule 1/2x 0.75 … 2.5 mm²
Flexible with Insulated Ferrule 1/2x 0.75 … 2.5 mm²
Flexible 1/2x 0.75 … 2.5 mm²
Rigid 1/2x 1 … 4 mm²
Connecting Capacity Main Circuit: Flexible with Ferrule 1/2x 0.75 … 2.5 mm²
Flexible with Insulated Ferrule 1/2x 0.75 … 2.5 mm²
Flexible 1/2x 0.75 … 2.5 mm²
Rigid 1/2x 1 … 4 mm²
Tightening Torque: Auxiliary Circuit 0.8 … 1.2 N·m
Main Circuit 0.8 … 1.5 N·m
Wire Stripping Length: Auxiliary Circuit 9 mm
Main Circuit 9 mm
Recommended Screw Driver: Auxiliary Circuit Pozidriv 2
Main Circuit Pozidriv 2
Mounting Position: 1 … 6
Power Loss: at Rated Operating Conditions per Pole 0.028 … 0.304 W
Suitable For: B6
B7
BC6
BC7
A09
A12
A16
AL09
AL12
AL16
VB6
VB7
VBC6
VBC7
Standards: IEC/EN 60947-1
IEC/EN 60947-4-1
IEC/EN 60947-5-1
UL 60947-1
UL 60947-4-1
Technical UL/CSA
Maximum Operating Voltage UL/CSA: Main Circuit 600 V AC
Contact Rating UL/CSA: B600
Q300
Connecting Capacity Main Circuit UL/CSA: Flexible 1/2x 16-10 AWG
Stranded 1/2x 16-10 AWG
Connecting Capacity Auxiliary Circuit UL/CSA: Flexible 1/2x 16-10 AWG
Stranded 1/2x 16-10 AWG
Tightening Torque UL/CSA: Auxiliary Circuit 7 in·lb
Main Circuit 7 in·lb
Environmental
Ambient Air Temperature: Operation -25 … +70 °C
Operation Compensated -25 … +70 °C
Storage -50 … +85 °C
Ambient Air Temperature Compensation: Yes
Maximum Operating Altitude Permissible: 2000 m
Resistance to Shock acc. to IEC 60068-2-27: 11 ms Pulse 15g
Resistance to Vibrations: 5g 3 … 150 Hz
RoHS Status: Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019
Toxic Substances Control Act – TSCA: 2CMT2023-006525
Material Compliance
Conflict Minerals Reporting Template (CMRT): 9AKK108467A5658
REACH Declaration: 2CMT2021-006202
RoHS Information: 2CMT2021-006277
RoHS Status: Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019
Toxic Substances Control Act – TSCA: 2CMT2023-006525
WEEE B2C / B2B: Business To Business
WEEE Category: 5. Small Equipment (No External Dimension More Than 50 cm)
Certificates and Declarations
CB Certificate: 1SAA964002-2002
CQC Certificate: CQC2008010309289447
Declaration of Conformity – CCC: 2020980309000285
Declaration of Conformity – CE: 1SAD101100-3602
Declaration of Conformity – UKCA: 1SAD201100-3602
EAC Certificate: 1SAA941003-2701
RMRS Certificate: 1SAA964000-0703
UL Certificate: E48139-19990512
Container Information
Package Level 1 Units: box 1 piece
Package Level 1 Width: 65 mm
Package Level 1 Height: 46 mm
Package Level 1 Depth / Length: 76.5 mm
Package Level 1 Gross Weight: 0.17 kg
Package Level 1 EAN: 4013614395260
Package Level 2 Units: 100 piece
Package Level 2 Width: 340 mm
Package Level 2 Height: 314 mm
Package Level 2 Depth / Length: 245 mm
Package Level 2 Gross Weight: 17.563 kg
Classifications
Object Classification Code: F
ETIM 4: EC001080 – Electronic overload relay
ETIM 5: EC001080 – Electronic overload relay
ETIM 6: EC001080 – Electronic overload relay
ETIM 7: EC001080 – Electronic overload relay
ETIM 8: EC001080 – Electronic overload relay
eClass: V11.0 : 27371502
UNSPSC: 39122330
IDEA Granular Category Code (IGCC): 5365 >> Electronic overload relay
E-Number (Finland): 3709394
E-Number (Sweden): 3228764

Downloads

Certificate Datasheet