Description
| ABB EcoSolutions | |
| ABB EcoSolutions: | Yes |
| Circular Value | |
| Circular Design Principles Recyclability Rate: | Design for Closing Resource Loops – Standard EN45555 – 55.9 % |
| End of Life Instructions: | 9AKK108468A2347 |
| Group Waste to Landfill Target: | UL 2799 Zero Waste To Landfill Validation available |
| Eco Transparency | |
| Environmental Product Declaration – EPD: | 9AKK108468A1890 9AKK108468A7793 |
| Environmental | |
| Environmental Information: | 9AKK108467A6707 |
| Material Compliance | |
| REACH Declaration: | 9AKK108466A1425 |
| RoHS Information: | 9AKK108466A1424 |
| RoHS Status: | Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019 |
| Conflict Minerals Reporting Template (CMRT): | 9AKK108467A5658 |
| Toxic Substances Control Act – TSCA: | 9AKK108467A8326 |
| SCIP: | 8cb3ed1b-4dd2-4c55-a8f6-faabe7c2b9ad Italy (IT) |
| Simplified SCIP: | 7f55227d-81b0-426c-b95d-87c224a5525b Spain (ES) f02605f6-fb0e-4e86-98af-0814a8d0ba70 Hungary (HU) d0ab3184-a0e7-41a0-9c0f-b2936d10155f Belgium (BE) 83abee8b-5b8f-4dae-9018-3f08f8109dfe Germany (DE) c49eab37-57f8-4b6e-84c4-ef9413dd28c2 Denmark (DK) 0b417151-96f3-4697-b26c-15be68f6f56b Sweden (SE) a733aefb-7fc4-4b91-aaf8-0cfa9038a88d Croatia (HR) c70822c6-3b77-41dc-9438-f29d72d6261c Germany (DE) 35f94476-ae3c-4f8f-a673-1e1004524daf Germany (DE) c55964cb-9eba-4808-98b2-9558a3643a72 Czech Republic (CZ) e4c49f80-81bb-456a-9545-3af28943ceae France (FR) 57858120-58a5-4f82-8b27-7242054e05d8 Poland (PL) 21eb8b7f-fbd0-44f2-afbe-65f5b5470087 Finland (FI) a656bff7-6b0a-4bcb-9873-06bcc001c424 Netherlands (NL) 85de621d-acc3-4fb3-852b-4537b886822d Norway (NO) e422f81e-d870-43eb-af88-077488e3c5bc Sweden (SE) 56123d5f-2c84-40b7-8116-79fa14e412d7 Bulgaria (BG) 1e925491-bad4-4cda-8f75-8d0f91c758c8 Portugal (PT) dd28347b-5e19-4326-831a-d3757956d536 Germany (DE) 7b88bc6a-b066-4793-9f9d-993f2163e806 Poland (PL) 0cc592fd-cdbe-4e10-aa1d-7efffb9d65e6 Germany (DE) b29ab876-8a3d-4ccc-9943-c92002afdb31 France (FR) 8ac237d2-0f40-437a-9c46-6cd5a1142107 Greece (GR) 06173978-d35f-4fd9-ad70-2c549716b779 Poland (PL) c1baa18a-7f83-4a85-9554-4483bebe4720 Hungary (HU) ba8fae24-e97e-45ec-a566-c60a2adc74b4 Estonia (EE) af8d3bdb-26fb-4075-847f-2b2d365fc2f8 Belgium (BE) |
| Ordering | |
| Order Code US and Canada: | XT1BE4025AFF000XXX |
| E-Number (Finland): | 3640505 |
| EAN: | 8015644007195 |
| Minimum Order Quantity: | 1 piece |
| Customs Tariff Number: | 85362090 |
| Dimensions | |
| Product Net Width: | 101.6 mm |
| Product Net Height: | 130 mm |
| Product Net Depth / Length: | 70 mm |
| Product Net Weight: | 1.4 kg |
| Container Information | |
| Package Level 1 Units: | box 1 piece |
| Package Level 1 Width: | 128 mm |
| Package Level 1 Height: | 135 mm |
| Package Level 1 Depth / Length: | 143 mm |
| Package Level 1 Gross Weight: | 1.424 kg |
| Package Level 1 EAN: | 8015644007195 |
| Additional Information | |
| Circuit Breaker Type to be Associated: | Power Distribution |
| Product Main Type: | SACE Tmax XT |
| Product Name: | Moulded Case Circuit Breaker |
| Product Type: | Automatic Circuit Breaker |
| Version: | F |
| CAD Dimensional Drawing: | 1SDH001295R0080 |
| Technical | |
| Connecting Capacity Main Circuit: | Busbar 45.5 … 80 mm² |
| Current Type: | AC/DC |
| Electrical Durability: | 120 cycles per hour 8000 cycle |
| Mechanical Durability: | 240 cycles per hour 25000 cycle |
| Number of Poles: | 4 |
| Opening Time: | CB with SOR 15 ms CB with UVR 15 ms |
| Order Multiple: | 1 piece |
| Power Loss: | at Rated Operating Conditions per Pole 2 W |
| Rated Current (In): | 25 A |
| Rated Frequency (f): | 50 / 60 Hz |
| Rated Impulse Withstand Voltage (Uimp): | 8 kV |
| Rated Instantaneous Short-Circuit Current Setting (Ii): | 450 A |
| Rated Insulation Voltage (Ui): | 800 V |
| Rated Operational Voltage: | 690 V AC 500 V DC |
| Rated Service Short-Circuit Breaking Capacity (Ics): | (220 V AC) 25 kA (230 V AC) 25 kA (240 V AC) 25 kA (380 V AC) 18 kA (415 V AC) 18 kA (440 V AC) 11.25 kA (500 V AC) 8 kA (525 V AC) 6 kA (690 V AC) 3 kA (250 V DC) 2 Poles in Series 18 kA (500 V DC) 3 Poles in Series 18 kA |
| Rated Ultimate Short-Circuit Breaking Capacity (Icu): | (220 V AC) 25 kA (230 V AC) 25 kA (240 V AC) 25 kA (380 V AC) 18 kA (415 V AC) 18 kA (440 V AC) 15 kA (500 V AC) 8 kA (525 V AC) 6 kA (690 V AC) 3 kA (250 V DC) 2 Poles in Series 18 kA (500 V DC) 3 Poles in Series 18 kA |
| Rated Uninterrupted Current (Iu): | 160 A |
| Rated Voltage (Ur): | 690 V |
| Recommended Screw Driver: | Main Circuit M6 |
| Release: | TMD |
| Release Type: | TM |
| Setting Range: | 17.5…25 A |
| Short-Circuit Performance Level: | B |
| Standards: | IEC60947-2 |
| Sub-type: | XT1 |
| Terminal Connection Type: | Front |
| Terminal Type: | Bolt |
| Tightening Torque: | 6 N·m |
| Certificates and Declarations | |
| ATEX Certificate: | No certification needed |
| Data Sheet, Technical Information: | 1SDC210100D0206 1SDC210099D0206 |
| Declaration of Conformity – CE: | 9AKK106713A5532 |
| GL Certificate: | 1SDL000163R0103 |
| LR Certificate: | 1SDL000163R0100 |
| UL Certificate: | No certification needed |
| VDE Certificate: | No certification needed |
| Dimension Diagram: | 1SDH000719R0100 |
| Mechanical Drawings: | 1SDH000719R0100 |
| Wiring Diagram: | 1SDM000068R0001 |
| Instructions and Manuals: | 1SDH000719R0001 |
| Classifications | |
| ETIM 8: | EC000228 – Power circuit-breaker for trafo/generator/installation protection |
| ETIM 9: | EC000228 – Power circuit-breaker for trafo/generator/installation protection |
| Object Classification Code: | Q |
| WEEE Category: | 5. Small Equipment (No External Dimension More Than 50 cm) |
| eClass: | V11.1 : 27370409 |