Description
| ABB EcoSolutions | |
| ABB EcoSolutions: | Yes |
| Circular Value | |
| Circular Design Principles Recyclability Rate: | Design for Closing Resource Loops – Standard EN45555 – 56.3 % |
| End of Life Instructions: | 9AKK108468A2351 |
| Group Waste to Landfill Target: | UL 2799 Zero Waste To Landfill Validation available |
| Eco Transparency | |
| Environmental Product Declaration – EPD: | 9AKK108469A1857 9AKK108468A1892 |
| Environmental | |
| Environmental Information: | 9AKK108467A6707 |
| Material Compliance | |
| REACH Declaration: | 9AKK108466A1425 |
| RoHS Information: | 9AKK108466A1424 |
| RoHS Status: | Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019 |
| Conflict Minerals Reporting Template (CMRT): | 9AKK108467A5658 |
| Toxic Substances Control Act – TSCA: | 9AKK108467A8326 |
| SCIP: | 825ef000-86ef-4390-b3bc-469b4df74414 Italy (IT) |
| Simplified SCIP: | d099b132-2ee3-4495-9251-a4214d0153e2 Germany (DE) cb69cc10-63ba-41bc-bda5-6e03afef0b0c France (FR) 40eb3dde-d3b2-406a-84b2-4e1f63035e08 Spain (ES) 34a4dc9f-1eec-432d-bc69-a23d9b967e02 Netherlands (NL) 7f78b6a1-9f5e-437f-bf87-938e43fbc68c Poland (PL) 7d306bbd-549c-4034-bcdc-f032dbe79dad Norway (NO) 94c56379-8fca-4a40-90da-227859ef3b3a Finland (FI) 467ed015-eaf9-4cfa-9c3c-9fbb93438f8a Sweden (SE) 8449ca87-1e19-4f50-9bdb-a73a181dbfb5 Germany (DE) efb9a579-3068-4246-ade0-55e6c2d93a1d Germany (DE) 1311aed6-b2fb-436a-94b9-58f9aabe78bc France (FR) 8a7e9128-6d32-46a7-a085-4c8ad467a9da Netherlands (NL) 435ee1cf-a647-4d14-917f-a92c18664a63 Netherlands (NL) 06d32ce4-2192-4b66-b435-1b8a3dffcde2 Germany (DE) a75d22c6-706c-4b95-a7c7-17d7a6b8ea5f Denmark (DK) 9fa63426-af62-4435-aeb2-89f997a7bc0d Germany (DE) 41ae1071-0864-43fe-9d1a-e4fee3be8061 Croatia (HR) 51202b64-a5f6-4add-b57d-ea00954dc5e4 Czech Republic (CZ) 34501fec-5f8a-40b3-83a7-964289f7d735 Poland (PL) 297c4a69-cd7e-4b69-b7ee-2d691192115e Netherlands (NL) d57b5d6d-2a78-44ba-8573-d248d355190e Netherlands (NL) 436a73af-7a7d-4e9e-ada8-2355988c26b0 Estonia (EE) 6afcc577-c53f-43c1-9b38-3e1bdb07daf4 Greece (GR) c32813d1-7891-418b-8719-4944cb65073a Portugal (PT) 7f5fce92-caf0-4896-b0c7-ac8ce1387064 Bulgaria (BG) c55d0677-9be7-446d-96e9-b3a3d55d77ea Sweden (SE) cf43b9fd-9c06-4093-b7e0-3c1c15e5b763 Poland (PL) |
| Ordering | |
| Order Code US and Canada: | XT4NE4250BFF000XXX |
| EAN: | 8015644695927 |
| Minimum Order Quantity: | 1 piece |
| Customs Tariff Number: | 85362090 |
| Dimensions | |
| Product Net Width: | 140 mm |
| Product Net Height: | 160 mm |
| Product Net Depth / Length: | 82.5 mm |
| Product Net Weight: | 2.872 kg |
| Container Information | |
| Package Level 1 Units: | box 1 piece |
| Package Level 1 Width: | 151 mm |
| Package Level 1 Height: | 214 mm |
| Package Level 1 Depth / Length: | 171 mm |
| Package Level 1 Gross Weight: | 3.023 kg |
| Package Level 1 EAN: | 8015644695927 |
| Additional Information | |
| Circuit Breaker Type to be Associated: | Power Distribution |
| Product Main Type: | SACE Tmax XT |
| Product Name: | Moulded Case Circuit Breaker |
| Product Type: | Automatic Circuit Breaker |
| Version: | F |
| CAD Dimensional Drawing: | 1SDH001295R0677 |
| Technical | |
| Connecting Capacity Main Circuit: | Busbar 85..200 mm² |
| Current Type: | AC/DC |
| Electrical Durability: | 120 cycles per hour 8000 cycle |
| Mechanical Durability: | 240 cycles per hour 25000 cycle |
| Number of Poles: | 4 |
| Opening Time: | CB with SOR 15 ms CB with UVR 15 ms |
| Order Multiple: | 1 piece |
| Power Loss: | at Rated Operating Conditions per Pole 16.44 W |
| Rated Current (In): | 250 A |
| Rated Frequency (f): | 50 / 60 Hz |
| Rated Impulse Withstand Voltage (Uimp): | 8 kV |
| Rated Instantaneous Short-Circuit Current Setting (Ii): | 1250€¦2500 A |
| Rated Insulation Voltage (Ui): | 1000 V |
| Rated Operational Voltage: | 690 V AC 750 V DC |
| Rated Service Short-Circuit Breaking Capacity (Ics): | (220 V AC) 65 kA (230 V AC) 65 kA (240 V AC) 65 kA (380 V AC) 36 kA (415 V AC) 36 kA (440 V AC) 36 kA (500 V AC) 30 kA (525 V AC) 20 kA (690 V AC) 10 kA (250 V DC) 2 Poles in Series 36 kA (500 V DC) 2 Poles in Series 36 kA (500 V DC) 3 Poles in Series 36 kA |
| Rated Ultimate Short-Circuit Breaking Capacity (Icu): | (220 V AC) 65 kA (230 V AC) 65 kA (240 V AC) 65 kA (380 V AC) 36 kA (415 V AC) 36 kA (440 V AC) 36 kA (500 V AC) 30 kA (525 V AC) 20 kA (690 V AC) 10 kA (250 V DC) 2 Poles in Series 36 kA (500 V DC) 2 Poles in Series 36 kA (500 V DC) 3 Poles in Series 36 kA |
| Rated Uninterrupted Current (Iu): | 250 A |
| Rated Voltage (Ur): | 690 V |
| Recommended Screw Driver: | Main Circuit M8 |
| Release: | TMA |
| Release Type: | TM |
| Setting Range: | 175…250 A |
| Short-Circuit Performance Level: | N |
| Standards: | IEC60947-2 |
| Sub-type: | XT4 |
| Terminal Connection Type: | Front |
| Terminal Type: | Bolt |
| Tightening Torque: | 8 N·m |
| Certificates and Declarations | |
| ATEX Certificate: | No certification needed |
| Data Sheet, Technical Information: | 1SDC210100D0206 1SDC210099D0206 |
| Declaration of Conformity – CE: | 9AKK106713A5529 |
| GL Certificate: | 1SDL000163R0095 |
| LR Certificate: | 1SDL000163R0100 |
| UL Certificate: | No certification needed |
| VDE Certificate: | No certification needed |
| Dimension Diagram: | 1SDH000722R0100 |
| Mechanical Drawings: | 1SDH000722R0100 |
| Wiring Diagram: | 1SDM000068R0001 |
| Instructions and Manuals: | 1SDH000722R0001 |
| Classifications | |
| ETIM 8: | EC000228 – Power circuit-breaker for trafo/generator/installation protection |
| ETIM 9: | EC000228 – Power circuit-breaker for trafo/generator/installation protection |
| Object Classification Code: | Q |
| UNSPSC: | 39120000 |
| WEEE Category: | 5. Small Equipment (No External Dimension More Than 50 cm) |
| eClass: | V11.1 : 27370409 |