Description
| ABB EcoSolutions | |
| ABB EcoSolutions: | Yes |
| EcoSolutions Profile: | 9AKK108469A3796 |
| Circular Value | |
| Circular Design Principles Recyclability Rate: | Design for Closing Resource Loops – Standard EN45555 – 87.8 % |
| Offered with Extended Lifetime: | Product Durability |
| End of Life Instructions: | 9AKK108468A3132 |
| Eco Transparency | |
| Environmental Product Declaration – EPD: | 9AKK108467A7832 |
| Technical | |
| Standards: | IEC/EN 60898-1 IEC/EN 60947-2 UL 1077 |
| Tripping Characteristic: | C |
| Rated Operational Voltage: | acc. to IEC 60898-1 400 V AC acc. to IEC 60898-1 400 V acc. to IEC 60947-2 440 V AC |
| Operational Voltage: | Maximum (Incl. Tolerance) 440 V AC Minimum 12 V AC Minimum 12 V DC |
| Rated Insulation Voltage (Ui): | acc. to IEC/EN 60664-1 440 V |
| Rated Impulse Withstand Voltage (Uimp): | 4 kV at 2000 m 5 kV at Sea Level 6.2 kV |
| Dielectric Test Voltage: | 50/60 Hz, 1 min: 2 kV |
| Input Voltage Type: | AC/DC |
| Rated Current (In): | 40 A |
| Rated Short-Circuit Capacity: | (AC) 6 kA (DC) 6 kA (400 V AC) 6 kA (400 V) 6 kA |
| Rated Ultimate Short-Circuit Breaking Capacity (Icu): | (230 V AC) 20 kA (400 V AC) 10 kA (440 V AC) 10 kA (230 V) 20 kA (400 V) 10 kA |
| Rated Conditional Short-Circuit Current (Inc): | (230 V) 20 kA (400 V) 20 kA |
| Rated Service Short-Circuit Breaking Capacity (Ics): | (230 V AC) 15 kA (400 V AC) 7.5 kA (440 V AC) 7.5 kA |
| Frequency (f): | 50 Hz |
| Rated Frequency (f): | 50 / 60 Hz |
| Power Loss: | 19.2 W at Rated Operating Conditions per Pole 4.8 W |
| Power Supply Connection: | Arbitrary |
| Contact Position Indication: | Red ON / Green OFF |
| Energy Limiting Class: | 3 |
| Electrical Endurance: | 10000 AC cycle |
| Mechanical Endurance: | 20000 cycle |
| Number of Protected Poles: | 4 |
| Number of Poles: | 4 |
| Overvoltage Category: | III |
| Tightening Torque: | 2.8 N·m |
| Mounting Type: | DIN-Rail |
| Screw Terminal Type: | Failsafe Bi-directional Cylinder-lift Terminal |
| Actuator Marking: | I / O |
| Actuator Material: | Insulation Group II, Black, Sealable |
| Housing Material: | Insulation Group II, RAL 7035 |
| Mounting on DIN Rail: | TH35-15 (35 x 15 mm Mounting Rail) acc. to IEC 60715 TH35-7.5 (35 x 7.5 mm Mounting Rail) acc. to IEC 60715 |
| Mounting Position: | any |
| Recommended Screw Driver: | Pozidriv 2 |
| Accessories Available: | Yes |
| Connecting Capacity: | Busbar 10 / 10 mm² Flexible with Ferrule 0.75 … 25 mm² Flexible 0.75 … 25 mm² Rigid 0.75 … 35 mm² Rigid 0.75 … 35 mm² Stranded 0.75 … 35 mm² |
| Installation Size: | acc. to DIN 43880 1 |
| Wire Stripping Length: | 12.5 mm |
| Terminal Type: | Screw Terminals |
| Material Compliance | |
| RoHS Information: | 2CDK403001D0607 |
| RoHS Status: | Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019 |
| RoHS Date: | 0335 |
| REACH Declaration: | 9AKK108468A9644 |
| REACH Information: | True – contains substances > 0.1 mass percentage |
| REACH Date: | 20231212 |
| Conflict Minerals Reporting Template (CMRT): | 9AKK108468A3363 |
| Environmental | |
| Ambient Air Temperature: | Operation -25 … +55 °C Storage -40 … +70 °C |
| Reference Ambient Air Temperature: | 30 °C |
| Degree of Protection: | IP20 IP40 Enclosure with Cover IP40 |
| Pollution Degree: | 3 |
| Environmental Conditions: | 28 cycles with 55 °C / 90-96 % and 25 °C / 95-100 % |
| Resistance to Vibrations: | 20 Cycles with Load 0.8 In: 5g 5 … 150 … 5 Hz |
| Resistance to Shock acc. to IEC 60068-2-27: | 25g 2 shocks 13 ms |
| Technical UL/CSA | |
| Maximum Operating Voltage UL/CSA: | 110 V DC 480Y/277 V AC |
| Interrupting Rating acc. to UL1077: | (277 V AC) 6 kA (480Y / 277 V AC) 6 kA (60 V DC) 10 kA (240 V) 10 kA |
| Connecting Capacity UL/CSA: | Busbar 18-8 AWG Conductor 18-4 AWG |
| Tightening Torque UL/CSA: | 18 in·lb |
| Dimensions | |
| Width in Number of Modular Spacings: | 4.0 |
| Product Net Width: | 70 mm |
| Product Net Height: | 88 mm |
| Product Net Depth / Length: | 69 mm |
| Product Net Weight: | 0.5 kg |
| Pole Net Weight: | 0.125 kg |
| Built-In Depth (t2): | 69 mm |
| Dimension Diagram: | 2CDC022007F0010 |
| Ordering | |
| Package Level 1 Units: | carton 1 piece |
| Package Level 1 Gross Weight: | 0.51 kg |
| E-Number (Finland): | 3211045 |
| Certificates and Declarations | |
| Certification Agency: | EN IEC UL |
| Declaration of Conformity – CE: | 2CDK403001D0607 |
| Declaration of Conformity – UKCA: | 9AKK108467A5053 |
| I²t Characteristic: | 9AKK107992A5102 |
| Installation | |
| Instructions and Manuals: | 2CDS207104P0002 |
| Popular Downloads | |
| Data Sheet, Technical Information: | 9AKK107991A8329 |
| I²t Characteristic: | 9AKK107992A5102 |
| Classifications | |
| ETIM 8: | EC000042 – Miniature circuit breaker (MCB) |
| ETIM 9: | EC000042 – Miniature circuit breaker (MCB) |
| WEEE Category: | 5. Small Equipment (No External Dimension More Than 50 cm) |
| WEEE B2C / B2B: | Business To Business |
| CN8: | 8536 20 10 |
| UNSPSC: | 39121603 |
| eClass: | V11.0 : 27141901 |
| IDEA Granular Category Code (IGCC): | 4897 >> Miniature circuit breakers |
| Object Classification Code: | F |