ABB A3S 400 TMF 320-3200 4p F F InN=100%In

General Information

Extended Product Type: A3S 400 TMF 320-3200 4p F F InN=100%In
Product ID: 1SDA066570R1
EAN: 8015644004828
Catalog Description: A3S 400 TMF 320-3200 4p F F InN=100%In
Long Description: C.BREAKER FORMULA A3S 400 FIXED FOUR-POLE WITH FRONT TERMINALS AND THERMOMAGNETIC RELEASE TMF R 320-3200 A FULLY RATED NEUTRAL

Description

Environmental
Environmental Information: 1SDL000185R001
9AKK108467A6707
Material Compliance
REACH Declaration: 9AKK108466A1425
RoHS Information: 9AKK108466A1424
RoHS Status: Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019
Conflict Minerals Reporting Template (CMRT): 9AKK108467A5658
Toxic Substances Control Act – TSCA: 9AKK108467A8326
Ordering
EAN: 8015644004828
Minimum Order Quantity: 1 piece
Customs Tariff Number: 85362090
Dimensions
Product Net Width: 186 mm
Product Net Height: 205 mm
Product Net Depth / Length: 103.5 mm
Product Net Weight: 6.4 kg
Container Information
Package Level 1 Units: 1 piece
Package Level 1 Width: 286 mm
Package Level 1 Height: 228 mm
Package Level 1 Depth / Length: 244 mm
Package Level 1 Gross Weight: 6.5 kg
Package Level 1 EAN: 8015644004828
Additional Information
Product Main Type: SACE FORMULA
Product Name: Moulded Case Circuit Breaker
Product Type: Automatic Circuit Breaker
Version: F
Technical
Electrical Durability: 2000 cycle
Mechanical Durability: 5000 cycle
Number of Poles: 4
Opening Time: CB with SOR 15 ms
CB with UVR ‰¤25 ms
Power Loss: at Rated Operating Conditions per Pole 13.6 W
Rated Current (In): Main Circuit 320 A
Rated Impulse Withstand Voltage (Uimp): 6 kV
Rated Insulation Voltage (Ui): 690 V
Rated Operational Voltage: 550 V AC
250 V DC
Rated Service Short-Circuit Breaking Capacity (Ics): (240 V AC) 50 kA
(380 V AC) 25 kA
(415 V AC) 25 kA
(440 V AC) 25 kA
(480 V AC) 17.5 kA
(500 V AC) 12.5 kA
(250 V DC) 2 Poles in Series 25 kA
Rated Ultimate Short-Circuit Breaking Capacity (Icu): (240 V AC) 100 kA
(380 V AC) 50 kA
(415 V AC) 50 kA
(440 V AC) 50 kA
(480 V AC) 35 kA
(500 V AC) 25 kA
(250 V DC) 2 Poles in Series 50 kA
Rated Uninterrupted Current (Iu): 400 A
Release: TMF
Release Type: TM
Short-Circuit Performance Level: S
Standards: IEC
Sub-type: A3
Terminal Connection Type: Front
Certificates and Declarations
Data Sheet, Technical Information: 1SDC210032D0204
Declaration of Conformity – CE: 9AKK106713A5517
Wiring Diagram: 1SDM000079R0001
Instructions and Manuals: 1SDH000747R0001
Classifications
ETIM 8: EC000228 – Power circuit-breaker for trafo/generator/installation protection
ETIM 9: EC000228 – Power circuit-breaker for trafo/generator/installation protection
Object Classification Code: Q
WEEE Category: 5. Small Equipment (No External Dimension More Than 50 cm)
eClass: V11.1 : 27370409

Downloads