Description
Environmental | |
Environmental Information: | 1SDL000185R001 9AKK108467A6707 |
Material Compliance | |
REACH Declaration: | 9AKK108466A1425 |
RoHS Information: | 9AKK108466A1424 |
RoHS Status: | Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019 |
Conflict Minerals Reporting Template (CMRT): | 9AKK108467A5658 |
Toxic Substances Control Act – TSCA: | 9AKK108467A8326 |
Ordering | |
EAN: | 8015644004828 |
Minimum Order Quantity: | 1 piece |
Customs Tariff Number: | 85362090 |
Dimensions | |
Product Net Width: | 186 mm |
Product Net Height: | 205 mm |
Product Net Depth / Length: | 103.5 mm |
Product Net Weight: | 6.4 kg |
Container Information | |
Package Level 1 Units: | 1 piece |
Package Level 1 Width: | 286 mm |
Package Level 1 Height: | 228 mm |
Package Level 1 Depth / Length: | 244 mm |
Package Level 1 Gross Weight: | 6.5 kg |
Package Level 1 EAN: | 8015644004828 |
Additional Information | |
Product Main Type: | SACE FORMULA |
Product Name: | Moulded Case Circuit Breaker |
Product Type: | Automatic Circuit Breaker |
Version: | F |
Technical | |
Electrical Durability: | 2000 cycle |
Mechanical Durability: | 5000 cycle |
Number of Poles: | 4 |
Opening Time: | CB with SOR 15 ms CB with UVR ‰¤25 ms |
Power Loss: | at Rated Operating Conditions per Pole 13.6 W |
Rated Current (In): | Main Circuit 320 A |
Rated Impulse Withstand Voltage (Uimp): | 6 kV |
Rated Insulation Voltage (Ui): | 690 V |
Rated Operational Voltage: | 550 V AC 250 V DC |
Rated Service Short-Circuit Breaking Capacity (Ics): | (240 V AC) 50 kA (380 V AC) 25 kA (415 V AC) 25 kA (440 V AC) 25 kA (480 V AC) 17.5 kA (500 V AC) 12.5 kA (250 V DC) 2 Poles in Series 25 kA |
Rated Ultimate Short-Circuit Breaking Capacity (Icu): | (240 V AC) 100 kA (380 V AC) 50 kA (415 V AC) 50 kA (440 V AC) 50 kA (480 V AC) 35 kA (500 V AC) 25 kA (250 V DC) 2 Poles in Series 50 kA |
Rated Uninterrupted Current (Iu): | 400 A |
Release: | TMF |
Release Type: | TM |
Short-Circuit Performance Level: | S |
Standards: | IEC |
Sub-type: | A3 |
Terminal Connection Type: | Front |
Certificates and Declarations | |
Data Sheet, Technical Information: | 1SDC210032D0204 |
Declaration of Conformity – CE: | 9AKK106713A5517 |
Wiring Diagram: | 1SDM000079R0001 |
Instructions and Manuals: | 1SDH000747R0001 |
Classifications | |
ETIM 8: | EC000228 – Power circuit-breaker for trafo/generator/installation protection |
ETIM 9: | EC000228 – Power circuit-breaker for trafo/generator/installation protection |
Object Classification Code: | Q |
WEEE Category: | 5. Small Equipment (No External Dimension More Than 50 cm) |
eClass: | V11.1 : 27370409 |