Description
ABB EcoSolutions | |
ABB EcoSolutions: | Yes |
Circular Value | |
Circular Design Principles Recyclability Rate: | Design for Closing Resource Loops – Standard EN45555 – 55.9 % |
End of Life Instructions: | 9AKK108468A2347 |
Group Waste to Landfill Target: | UL 2799 Zero Waste To Landfill Validation available |
Eco Transparency | |
Environmental Product Declaration – EPD: | 9AKK108468A1890 9AKK108468A7793 |
Environmental | |
Environmental Information: | 9AKK108467A6707 |
Material Compliance | |
REACH Declaration: | 9AKK108466A1425 |
RoHS Information: | 9AKK108466A1424 |
RoHS Status: | Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019 |
Conflict Minerals Reporting Template (CMRT): | 9AKK108467A5658 |
Toxic Substances Control Act – TSCA: | 9AKK108467A8326 |
SCIP: | f73e4266-0af4-4cef-b9b3-260c00a910f9 Italy (IT) |
Simplified SCIP: | 7aac2671-b6b8-4dcf-aa1e-3f4dba5449be Germany (DE) 06390208-d394-410e-9842-b8f1aa84ad09 Poland (PL) ce31830e-4feb-4262-8ac1-c0a505cbd58c Norway (NO) 43aad17a-9e80-44f3-9db3-9d6d35642925 Finland (FI) e181dcff-17e3-4829-8167-be0ead9f9f4f Netherlands (NL) 7515b418-fb55-4766-95e2-4323a6ecd612 Germany (DE) 45a6cb81-5081-41fe-a071-5cf38b8adf65 Denmark (DK) ff639201-5b12-440f-821d-3a6c4ce2953c Germany (DE) f913e764-1c76-4c93-9fc0-2a0875805dc8 Croatia (HR) dc0ff913-83d0-4f15-babc-7a856a1b3255 Czech Republic (CZ) b020eaeb-cf23-445c-95a4-4f103ce43fa5 Poland (PL) fa9663ae-4d74-4267-a4b0-fcfc539c2914 Netherlands (NL) a409c160-db3e-4860-adba-1d89501dd2c5 Netherlands (NL) aebf759a-29ca-419e-b416-0ecf3b3f9577 Estonia (EE) e0db3e96-345c-4b56-91d0-3a02a89a2482 Greece (GR) 094c590f-e054-4452-9a76-5fb143f976e9 Portugal (PT) 2e656ab5-eff3-4755-bcc3-052950d58ddb Bulgaria (BG) df9ecf69-1483-4540-b0c4-3bdfc49abdad Sweden (SE) c6236bbe-bf16-4be7-9c71-7d042fe7dbe1 Poland (PL) d6074c8c-4abc-41ae-ad9f-fa07173c3572 France (FR) 382fe93d-82da-457d-b30e-7032f1b8681e Sweden (SE) 908a3719-74a3-4ad9-8c4f-413f7b640fe2 Germany (DE) c0dd578e-17bc-4735-a4bd-35aac606fc6d Germany (DE) f358ac58-4638-4878-b499-0f7191ed7405 France (FR) efc96197-3e4f-4d77-a0c4-4a5c216675e2 Netherlands (NL) 9131538b-9a93-4dc4-88d8-690a0b2651e3 Spain (ES) d203dbb9-dd7c-4d5d-ad5c-3e96966e8826 Netherlands (NL) |
Ordering | |
Order Code US and Canada: | XT1BE3032AFF000XXX |
E-Number (Finland): | 3638629 |
EAN: | 8015644694463 |
Minimum Order Quantity: | 1 piece |
Customs Tariff Number: | 85362090 |
Dimensions | |
Product Net Width: | 76.2 mm |
Product Net Height: | 130 mm |
Product Net Depth / Length: | 70 mm |
Product Net Weight: | 1.1 kg |
Container Information | |
Package Level 1 Units: | box 1 piece |
Package Level 1 Width: | 128 mm |
Package Level 1 Height: | 135 mm |
Package Level 1 Depth / Length: | 143 mm |
Package Level 1 Gross Weight: | 1.11 kg |
Package Level 1 EAN: | 8015644694463 |
Additional Information | |
Circuit Breaker Type to be Associated: | Power Distribution |
Product Main Type: | SACE Tmax XT |
Product Name: | Moulded Case Circuit Breaker |
Product Type: | Automatic Circuit Breaker |
Version: | F |
CAD Dimensional Drawing: | 1SDH001295R0008 |
Technical | |
Connecting Capacity Main Circuit: | Busbar 45.5 … 80 mm² |
Current Type: | AC/DC |
Electrical Durability: | 120 cycles per hour 8000 cycle |
Mechanical Durability: | 240 cycles per hour 25000 cycle |
Number of Poles: | 3 |
Opening Time: | CB with SOR 15 ms CB with UVR 15 ms |
Order Multiple: | 1 piece |
Power Loss: | at Rated Operating Conditions per Pole 2.1 W |
Rated Current (In): | 32 A |
Rated Frequency (f): | 50 / 60 Hz |
Rated Impulse Withstand Voltage (Uimp): | 8 kV |
Rated Instantaneous Short-Circuit Current Setting (Ii): | 450 A |
Rated Insulation Voltage (Ui): | 800 V |
Rated Operational Voltage: | 690 V AC 500 V DC |
Rated Service Short-Circuit Breaking Capacity (Ics): | (220 V AC) 25 kA (230 V AC) 25 kA (240 V AC) 25 kA (380 V AC) 18 kA (415 V AC) 18 kA (440 V AC) 11.25 kA (500 V AC) 8 kA (525 V AC) 6 kA (690 V AC) 3 kA (250 V DC) 2 Poles in Series 18 kA (500 V DC) 3 Poles in Series 18 kA |
Rated Ultimate Short-Circuit Breaking Capacity (Icu): | (220 V AC) 25 kA (230 V AC) 25 kA (240 V AC) 25 kA (380 V AC) 18 kA (415 V AC) 18 kA (440 V AC) 15 kA (500 V AC) 8 kA (525 V AC) 6 kA (690 V AC) 3 kA (250 V DC) 2 Poles in Series 18 kA (500 V DC) 3 Poles in Series 18 kA |
Rated Uninterrupted Current (Iu): | 160 A |
Rated Voltage (Ur): | 690 V |
Recommended Screw Driver: | Main Circuit M6 |
Release: | TMD |
Release Type: | TM |
Setting Range: | 22.4…32 A |
Short-Circuit Performance Level: | B |
Standards: | IEC60947-2 |
Sub-type: | XT1 |
Terminal Connection Type: | Front |
Terminal Type: | Bolt |
Tightening Torque: | 6 N·m |
Certificates and Declarations | |
ATEX Certificate: | No certification needed |
Data Sheet, Technical Information: | 1SDC210100D0206 1SDC210099D0206 |
Declaration of Conformity – CE: | 9AKK106713A5532 |
GL Certificate: | 1SDL000163R0103 |
LR Certificate: | 1SDL000163R0100 |
UL Certificate: | No certification needed |
VDE Certificate: | No certification needed |
Dimension Diagram: | 1SDH000719R0100 |
Mechanical Drawings: | 1SDH000719R0100 |
Wiring Diagram: | 1SDM000068R0001 |
Instructions and Manuals: | 1SDH000719R0001 |
Classifications | |
ETIM 8: | EC000228 – Power circuit-breaker for trafo/generator/installation protection |
ETIM 9: | EC000228 – Power circuit-breaker for trafo/generator/installation protection |
Object Classification Code: | Q |
WEEE Category: | 5. Small Equipment (No External Dimension More Than 50 cm) |
eClass: | V11.1 : 27370409 |