ABB EcoSolutions | |
ABB EcoSolutions: | Yes |
Circular Value | |
Circular Design Principles Recyclability Rate: | Design for Closing Resource Loops – Standard EN45555 – 55.9 % |
End of Life Instructions: | 9AKK108468A2347 |
Group Waste to Landfill Target: | UL 2799 Zero Waste To Landfill Validation available |
Eco Transparency | |
Environmental Product Declaration – EPD: | 9AKK108468A1890 9AKK108468A7793 |
Environmental | |
Environmental Information: | 9AKK108467A6707 |
Material Compliance | |
REACH Declaration: | 9AKK108466A1425 |
RoHS Information: | 9AKK108466A1424 |
RoHS Status: | Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019 |
Conflict Minerals Reporting Template (CMRT): | 9AKK108467A5658 |
Toxic Substances Control Act – TSCA: | 9AKK108467A8326 |
SCIP: | 04c3bfad-7e1c-429f-8614-00ca8b4c8246 Italy (IT) |
Simplified SCIP: | c980eb9d-c930-4207-be79-18998991e543 Germany (DE) 05fb5747-1f6a-4fcb-9a95-e2bdce382aac Finland (FI) c5611fb4-697a-488c-9338-65a1ac58eb95 Norway (NO) 23235400-6bd4-4005-9580-19e41cbbc1c5 France (FR) 0569b031-ea62-4cca-8a66-2a5b16c051db Netherlands (NL) 76b8a86b-345a-4f87-8d62-e34024531bb1 Netherlands (NL) 521705a5-2bef-44ad-81eb-960bc18a89de Germany (DE) cbc69345-80fd-4f24-b3e6-425db0c63237 Denmark (DK) b876a3e8-bbb3-4dbe-a7cf-512672b07ca8 Germany (DE) 3cd9e697-fec2-4f2d-9681-47dc0ae309c0 Croatia (HR) b904a269-358b-499d-a085-4d8b460a7633 Czech Republic (CZ) 7b4a72b6-f994-4e65-9d03-242b5d5c3192 Netherlands (NL) cf35da3b-5c64-4bcc-98b6-aff088652e20 Netherlands (NL) 578f336c-409f-4c42-9b01-632b40455d3e Estonia (EE) 2f9cdf36-8c74-4b82-94b4-4bc1f9ab598d Greece (GR) 98cc3dce-cbf3-4df0-8442-37a76e349926 Portugal (PT) ebc38d72-c2f5-4095-b7bb-79d6614fad1c Bulgaria (BG) 7bf3683a-2ee1-4e65-846d-92e406efe465 Sweden (SE) 752581a0-5f0e-44f0-9041-c39837a6d0ab Poland (PL) 0d72cced-ae48-410b-a802-dc326cb682a0 France (FR) 39135c8a-e65a-47ee-a08f-de1fcf1003dd Sweden (SE) 3c430bd8-7130-472d-b527-4fec966dbf44 Germany (DE) 55073784-ba76-4be2-b976-89ebdb00e7ec Germany (DE) af5e7d2d-78a6-41ca-a1c5-789825f77f7b Spain (ES) 01379f3e-f9b3-49cb-b5fe-a9fc100efbb2 Netherlands (NL) ec955a84-1183-4e95-b1c4-26f4a66dd5a1 Poland (PL) 9ba63e07-44d1-4f2f-b19d-610254983f6d Poland (PL) |
Ordering | |
Order Code US and Canada: | XT1CE3125AFF000XXX |
E-Number (Finland): | 3638778 |
EAN: | 8015644012922 |
Minimum Order Quantity: | 1 piece |
Customs Tariff Number: | 85362090 |
Dimensions | |
Product Net Width: | 76.2 mm |
Product Net Height: | 130 mm |
Product Net Depth / Length: | 70 mm |
Product Net Weight: | 1.1 kg |
Container Information | |
Package Level 1 Units: | box 1 piece |
Package Level 1 Width: | 128 mm |
Package Level 1 Height: | 135 mm |
Package Level 1 Depth / Length: | 143 mm |
Package Level 1 Gross Weight: | 1.137 kg |
Package Level 1 EAN: | 8015644012922 |
Additional Information | |
Circuit Breaker Type to be Associated: | Power Distribution |
Product Main Type: | SACE Tmax XT |
Product Name: | Moulded Case Circuit Breaker |
Product Type: | Automatic Circuit Breaker |
Version: | F |
CAD Dimensional Drawing: | 1SDH001295R0008 |
Technical | |
Connecting Capacity Main Circuit: | Busbar 45.5 … 80 mm² |
Current Type: | AC/DC |
Electrical Durability: | 120 cycles per hour 8000 cycle |
Mechanical Durability: | 240 cycles per hour 25000 cycle |
Number of Poles: | 3 |
Opening Time: | CB with SOR 15 ms CB with UVR 15 ms |
Order Multiple: | 1 piece |
Power Loss: | at Rated Operating Conditions per Pole 10.7 W |
Rated Current (In): | 125 A |
Rated Frequency (f): | 50 / 60 Hz |
Rated Impulse Withstand Voltage (Uimp): | 8 kV |
Rated Instantaneous Short-Circuit Current Setting (Ii): | 1250 A |
Rated Insulation Voltage (Ui): | 800 V |
Rated Operational Voltage: | 690 V AC 500 V DC |
Rated Service Short-Circuit Breaking Capacity (Ics): | (220 V AC) 40 kA (230 V AC) 40 kA (240 V AC) 40 kA (380 V AC) 25 kA (415 V AC) 25 kA (440 V AC) 12.5 kA (500 V AC) 9 kA (525 V AC) 8 kA (690 V AC) 4 kA (250 V DC) 2 Poles in Series 25 kA (500 V DC) 3 Poles in Series 25 kA |
Rated Ultimate Short-Circuit Breaking Capacity (Icu): | (220 V AC) 40 kA (230 V AC) 40 kA (240 V AC) 40 kA (380 V AC) 25 kA (415 V AC) 25 kA (440 V AC) 25 kA (500 V AC) 18 kA (525 V AC) 8 kA (690 V AC) 4 kA (250 V DC) 2 Poles in Series 25 kA (500 V DC) 3 Poles in Series 25 kA |
Rated Uninterrupted Current (Iu): | 160 A |
Rated Voltage (Ur): | 690 V |
Recommended Screw Driver: | Main Circuit M6 |
Release: | TMD |
Release Type: | TM |
Setting Range: | 87.5…125 A |
Short-Circuit Performance Level: | C |
Standards: | IEC60947-2 |
Sub-type: | XT1 |
Terminal Connection Type: | Front |
Terminal Type: | Bolt |
Tightening Torque: | 6 N·m |
Certificates and Declarations | |
ATEX Certificate: | No certification needed |
Data Sheet, Technical Information: | 1SDC210100D0206 1SDC210099D0206 |
Declaration of Conformity – CE: | 9AKK106713A5532 |
GL Certificate: | 1SDL000163R0103 |
LR Certificate: | 1SDL000163R0100 |
UL Certificate: | No certification needed |
VDE Certificate: | No certification needed |
Dimension Diagram: | 1SDH000719R0100 |
Mechanical Drawings: | 1SDH000719R0100 |
Wiring Diagram: | 1SDM000068R0001 |
Instructions and Manuals: | 1SDH000719R0001 |
Classifications | |
ETIM 8: | EC000228 – Power circuit-breaker for trafo/generator/installation protection |
ETIM 9: | EC000228 – Power circuit-breaker for trafo/generator/installation protection |
Object Classification Code: | Q |
UNSPSC: | 39120000 |
WEEE Category: | 5. Small Equipment (No External Dimension More Than 50 cm) |
eClass: | V11.1 : 27370409 |