Description
| ABB EcoSolutions | |
| ABB EcoSolutions: | Yes |
| Circular Value | |
| Circular Design Principles Recyclability Rate: | Design for Closing Resource Loops – Standard EN45555 – 56.30 % |
| End of Life Instructions: | 9AKK108468A2351 |
| Group Waste to Landfill Target: | UL 2799 Zero Waste To Landfill Validation available |
| Eco Transparency | |
| Environmental Product Declaration – EPD: | 9AKK108469A1857 9AKK108468A1892 |
| Environmental | |
| Environmental Information: | 9AKK108467A6707 |
| Material Compliance | |
| REACH Declaration: | 9AKK108466A1425 |
| RoHS Information: | 9AKK108466A1424 |
| RoHS Status: | Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019 |
| Conflict Minerals Reporting Template (CMRT): | 9AKK108467A5658 |
| Toxic Substances Control Act – TSCA: | 9AKK108467A8326 |
| SCIP: | 6facd17f-dd1b-48af-bf50-e35fa1f73523 Italy (IT) |
| Simplified SCIP: | 37fbe0e1-0c4c-4e0b-b87e-2532981208e7 Germany (DE) 9771597a-8b6f-4398-be7b-5255db45d73e Czech Republic (CZ) e75fdd14-8826-4b0d-9a3e-3bd30f3529d0 Denmark (DK) 7e28d83e-974b-4d27-aad3-8eaaaef5e00d Sweden (SE) 5297a453-f9a0-4031-9ee2-d82eeac21ae3 Germany (DE) fc7dfc2f-8add-4641-9a0e-606e7d2b2024 Croatia (HR) ab60f2e5-23c6-485b-aeb9-8118922fe664 Germany (DE) 1205764b-7824-46c7-b3ab-97381154d72a France (FR) 32225bd5-5a64-4acd-a760-f0252e292351 Hungary (HU) c6ecafc3-801c-4594-8210-cd3bf2037e6e Spain (ES) 225f1ba6-eb90-419c-a98c-287690c7e1c4 Belgium (BE) 742461d8-b0ba-4f17-8e1f-523936ebbd57 Portugal (PT) bc7da002-e8b8-447c-8b85-fe4116b7f849 Sweden (SE) 8536b0e6-16f4-48e8-8e30-95810d990f68 Hungary (HU) badfcaf9-d16d-4a04-912f-427442e97d33 Poland (PL) 212a2ce2-cf13-42b7-88fa-df0bd42ce1e5 Finland (FI) 3ea0eb24-05e0-407f-aa39-65ea89c685f0 Estonia (EE) 92c74314-0575-49fb-8cbe-df8daf5f881f Belgium (BE) 065433d6-d490-40e8-9df3-0b1212c01cab Greece (GR) 73888a28-f125-4b7c-a71d-bc7df35c84f7 France (FR) 30bc143d-7264-4e53-9cd5-2a14793efc5b Germany (DE) b8636fd8-0473-4474-8659-d211136256a1 Poland (PL) 4568fdea-35ba-4599-a10e-157f02d2e190 Bulgaria (BG) 8c48bf41-19f8-4a1f-82c7-a788eaad912b Netherlands (NL) 3a387e7e-ba2f-466a-8167-6735b75ab2ea Norway (NO) de56acf7-aac6-4d46-89fa-854899cded93 Poland (PL) a2e1124a-1b1c-4b37-895f-6870b2ff7264 Germany (DE) |
| Ordering | |
| Order Code US and Canada: | XT4SE3200BFF000XXX |
| E-Number (Finland): | 3641052 |
| EAN: | 8015644022167 |
| Minimum Order Quantity: | 1 piece |
| Customs Tariff Number: | 85362090 |
| Dimensions | |
| Product Net Width: | 105 mm |
| Product Net Height: | 160 mm |
| Product Net Depth / Length: | 82.5 mm |
| Product Net Weight: | 2.26 kg |
| Container Information | |
| Package Level 1 Units: | box 1 piece |
| Package Level 1 Width: | 151 mm |
| Package Level 1 Height: | 214 mm |
| Package Level 1 Depth / Length: | 171 mm |
| Package Level 1 Gross Weight: | 2.35 kg |
| Package Level 1 EAN: | 8015644022167 |
| Additional Information | |
| Circuit Breaker Type to be Associated: | Power Distribution |
| Product Main Type: | SACE Tmax XT |
| Product Name: | Moulded Case Circuit Breaker |
| Product Type: | Automatic Circuit Breaker |
| Version: | F |
| CAD Dimensional Drawing: | 1SDH002230A1003 |
| Technical | |
| Connecting Capacity Main Circuit: | Busbar 85..200 mm² |
| Current Type: | AC/DC |
| Electrical Durability: | 120 cycles per hour 8000 cycle |
| Mechanical Durability: | 240 cycles per hour 25000 cycle |
| Number of Poles: | 3 |
| Opening Time: | CB with SOR 15 ms CB with UVR 15 ms |
| Order Multiple: | 1 piece |
| Power Loss: | at Rated Operating Conditions per Pole 11.88 W |
| Rated Current (In): | 200 A |
| Rated Frequency (f): | 50 / 60 Hz |
| Rated Impulse Withstand Voltage (Uimp): | 8 kV |
| Rated Instantaneous Short-Circuit Current Setting (Ii): | 1000€¦2000 A |
| Rated Insulation Voltage (Ui): | 1000 V |
| Rated Operational Voltage: | 690 V AC 750 V DC |
| Rated Service Short-Circuit Breaking Capacity (Ics): | (220 V AC) 85 kA (230 V AC) 85 kA (240 V AC) 85 kA (380 V AC) 50 kA (415 V AC) 50 kA (440 V AC) 50 kA (500 V AC) 36 kA (525 V AC) 25 kA (690 V AC) 12 kA (250 V DC) 2 Poles in Series 50 kA (500 V DC) 2 Poles in Series 50 kA (500 V DC) 3 Poles in Series 50 kA |
| Rated Ultimate Short-Circuit Breaking Capacity (Icu): | (220 V AC) 85 kA (230 V AC) 85 kA (240 V AC) 85 kA (380 V AC) 50 kA (415 V AC) 50 kA (440 V AC) 50 kA (500 V AC) 36 kA (525 V AC) 25 kA (690 V AC) 12 kA (250 V DC) 2 Poles in Series 50 kA (500 V DC) 2 Poles in Series 50 kA (500 V DC) 3 Poles in Series 50 kA |
| Rated Uninterrupted Current (Iu): | 250 A |
| Rated Voltage (Ur): | 690 V |
| Recommended Screw Driver: | Main Circuit M8 |
| Release: | TMA |
| Release Type: | TM |
| Setting Range: | 140…200 A |
| Short-Circuit Performance Level: | S |
| Standards: | IEC60947-2 |
| Sub-type: | XT4 |
| Terminal Connection Type: | Front |
| Terminal Type: | Bolt |
| Tightening Torque: | 8 N·m |
| Certificates and Declarations | |
| ATEX Certificate: | No certification needed |
| Data Sheet, Technical Information: | 1SDC210100D0206 1SDC210099D0206 |
| Declaration of Conformity – CE: | 9AKK106713A5529 |
| GL Certificate: | 1SDL000163R0095 |
| LR Certificate: | 1SDL000163R0100 |
| UL Certificate: | No certification needed |
| VDE Certificate: | No certification needed |
| Dimension Diagram: | 1SDH000722R0100 |
| Mechanical Drawings: | 1SDH000722R0100 |
| Wiring Diagram: | 1SDM000068R0001 |
| Instructions and Manuals: | 1SDH000722R0001 |
| Classifications | |
| ETIM 8: | EC000228 – Power circuit-breaker for trafo/generator/installation protection |
| ETIM 9: | EC000228 – Power circuit-breaker for trafo/generator/installation protection |
| Object Classification Code: | Q |
| UNSPSC: | 39120000 |
| WEEE Category: | 5. Small Equipment (No External Dimension More Than 50 cm) |
| eClass: | V11.1 : 27370409 |